OPERATION | ||
|
|
|
SET UP MENU
Many additional parameters can be modified via the Set Up Menu. To access the Set Up Menu:
•Position the ON/OFF switch to OFF “0”.
•Depress and hold the Parameter select Push Button.
•Position the On/Off switch to on "I" at the back of the machine; the input voltage light "Item 1" (green LED) confirms normal operation.
•The SETUP mode is confirmed by a center "0" on the Digital display “Item 6”.
-Rotate the Output / Parameter Adjust Knob, the Digital Display shows the numbers corresponding to the parameters in sequence; stop at the desired parameter and push the "Setup/Parameter Push Button".
-The number on the Digital display "Item 6" is replaced by the value of the parameter that can be modified through the Output / Parameter adjust knob "Item 5".
-With parameter (9) all the modifications made in the SETUP mode are cancelled and the standard values set by Invertec
-To exit the Set Up Menu, return to “0” and press the Setup/Parameter Push Button
INDICATOR | PARAMETER | DEFAULT | ||
|
|
|
| |
0 | Exit From Set Up |
|
| |
2 | Pre Flow Time (0 - 25 seconds) | 0.5 sec. |
| |
3 | Arc Force Soft Mode, Percent above Peak Current for Stick only | 30% |
| |
4 | Hot Start Soft Mode, Percent above Peak Current for Stick only | 80% |
| |
5 | Arc Force Crisp Mode, Pecent above Peak Current for Stick only | 350% |
| |
6 | Hot Start Crisp Mode, Percent above Peak Current for Stick only | 150% |
| |
| Setting the AC Wave Form (AC/DC model only) |
|
| |
7 | 0=Sinusoidal | 2 (Square) | ||
1=Triangular | ||||
|
| |||
|
|
| ||
| 2=Square |
|
| |
| VRD |
|
| |
| Off=Disabled |
|
| |
8 | 1=Enable (limits OCV to 12V) | Off | ||
| 2=Enable (limits OCV to 20V) |
|
| |
| 3=Enable (limits OCV to 30V) |
|
| |
| Max Current Value with Remote Control |
|
| |
9 | (6 Amps - Peak Current) | Peak Current | ||
| NOTE: Peak Current (Max Weld Current) can be limited by input voltage, welding mode, AC TIG waveform and AC TIG frequency. |
|
| |
10 | Lift or HF Start in DC, Ignored in AC (0 = HF Start, 1 Touch Start) | HF | ||
11 | Reset of all Parameters |
|
| |
12 | DC TIG STRIKE CURRENT | 40 Amps | ||
13 | DC TIG Start Polarity 0=DC- or 1=DC+ | 0 |
| |
| 2 Step Trigger Selection |
|
| |
14 | 0 = Restart Disabled | 1 |
| |
| 1 = Restart Enabled |
|
| |
| 4 Step Trigger Selection |
|
| |
15 | 0 = Restart Disabled | 0 |
| |
| 1 = Restart Enabled |
|
| |
| AC TIG Start Power (for AC TIG only on AC/DC model) |
|
| |
| This function sets the initial start energy limit. Set this number to a |
|
| |
| higher setting than the factory default if needed to improve starting |
|
| |
| of large diameter tungsten electrodes. |
|
| |
16 | 0.5 to 1.0 manual start energy setting | 2 |
| |
| 1.2 to 5.0 = max. Incrementing limit (See Note) |
|
| |
| Note: The machine will try to start the machine at a start power of 1. |
|
| |
| If the arc does not establish it will incrementally increase the start |
|
| |
| power and try to restrike up to the set limit. |
|
| |
| TIG PULSED BASE CURRENT Setting: |
|
| |
17 | 0 = Absolute value setting | 1 |
| |
| 1 = Percentage value setting |
|
| |
|
|
|
|