Lincoln Electric 205-TAC/DCTIG manual Optional Accessories, Compatible Equipment, Cable Plugs

Page 28

C-1

ACCESSORIES

C-1

 

 

 

OPTIONAL ACCESSORIES

AND COMPATIBLE EQUIPMENT

Factory Installed

Twist-Mate Cable Connectors

1 – standard for Ground Clamp

1 – Gas Pass through for Tig Torch

Strap Packet

Instruction Manual

Field Installed

K857 - Remote Output Control - For Stick welding. When the V205-Tʼs Output Control is in the "REMOTE" position, this portable current control pro- vides the same range as the current control on the welder. Consists of a 6-pin Amphenol connector which plugs into the remote control Amphenol. 25 foot cable length.

K870 - Foot Amptroltm for TIG welding. When the V205-Tʼs Output Control is in the “REMOTE” position, the foot Amptrol energizes the output and controls the output remotely. The Foot Amptrol connects directly to the 6 pin Amphenol.

K963-3 - Hand Amptroltm for TIG welding. When the V205-Tʼs Output Control is in the “Remote” position, the hand Amptrol energizes the output and controls the output remotely. The Hand Amptrol connects directly to the 6 pin Amphenol.

K814 - Arc Start Switch - Energizes the output for TIG welding if remote output control of the amperage is not desired. It allows on/off TIG welding at the cur- rent set by the Current Control on the control panel. When using the Arc Start Switch set the Output Control to the “LOCAL” position.

Magnum® PTA-9 and PTA-17 TIG Torches - The following standard Magnum® TIG torches with one- piece cable may be used with the Invertec V205-T.

K1781-1

PTA-9

12.5 ft

medium back cap

K1781-3

PTA-9

25 ft

medium back cap

K1782-1

PTA-17

12.5 ft

long back cap

K1782-3

PTA-17

25 ft

long back cap

NOTE: Each torch requires a Twist-Mate™ adapter, (one is included with the machine). Collets, collet bod- ies, and nozzles are not included and must be ordered separately.

TIG TORCH KITS

K2266-1TIG-Mate 17 Air Cooled TIG Torch Starter Pack. One complete easy-to-order kit pack- aged in its own portable carrying case. Includes: PTA- 17 torch, parts kit, Harris flowmeter/regulator, 10 ft. gas hose, Twist-Mate™ adapter, work clamp and cable.

K2267-1TIG-Mate 20 Water-Cooled TIG Torch Starter Pack. One complete easy-to-order kit pack- aged in its own portable carrying case. Includes: PTW-20 torch, parts kit, Harris flowmeter/regulator, 10 ft. gas hose, Twist-Mate™ adapter, work clamp and cable, and 10 ft. water hose.

K2413-1- TIG-Mate 9 Air Cooled TIG Torch Starter Pack. One complete easy-to-order Kit packaged in its own portable carring case. Includes: PTA-9 Torch, Gas Lens Parts Kit, Harris flowmeter/regulator, 10 Ft. gas hose, Twist-Mate™ adapter, work clamp and cable.

CABLE PLUGS

K852-70 - Cable Plug Kit for 1/0-2/0 cable. Attaches to welding cable to provide quick disconnect from machine.

Twist-Mate Torch Adapter K1622-1 - One is shipped with the welder torch. If you do not care to interchange this part between torches (one is required to connect Magnum PTA-9 or PTA-17 TIG torches with one-piece cable to the V205-T) you may order an additional adapters. The quick connect plug provides connection for both gas and welding current.

K1622-4Twist-Mate adapter for Water-Cooled TIG torches. Adapter for PTW-18 and -20 Torches.

TIG Torch Parts Kits - Parts kits are available for the PTA-9 and PTA-17 TIG torches. These kits include back cap, collets, collet bodies, nozzles and tung- stens.

Order KP507 for PTA-9 torches Order KP508 for PTA-17 torches

Order KP2414-1Gas Lens Parts kit for PTA-9 torches

See publication E12.150 for parts kits breakdown. Cut Length Consumables - TIG welding filler metals are available for welding stainless steel, mild steel, aluminum and copper alloys. See publication C9.10.

V205-T DC & V205-T AC/DC TIG

Image 28
Contents Invertec V205-T DC & V205-T AC/DC TIG April Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcV205-T DC & V205-T AC/DC TIG Safety Thank You Table of Contents Operating Temperature Range InstallationStorage Temperature Range Select Suitable Location StackingTilting Environmental AreaReconnect Procedure Input ConnectionsTable A.1 Nominal RangeAttachment Plug Installation 230V Input115V Input Engine Driven GeneratorOutput Connection for Stick Welding Figure A.2 Output and GAS Connection for TIG Welding Figure A.1Work Cable Connection Remote Control Connection Shielding GAS ConnectionSafety Instructions OperationGeneral Description Welding CapabilityRear Control Panel Figure B.1 Figure B.1Controls and Settings Figure B.2Step Diagram TIG DC SET UP Menu Indicator Parameter DefaultOutput Limitations Welding PolarityPulsed TIG Alternating Current AC/DC model onlySteel TIG Welding Copper TIG WeldingTips for AC TIG Welding Filler Material Tips for Improved TIG Starting Protective GASAC TIG Welding Quick Start UP AC TIGDC TIG Welding Quick Start UP Accessories Optional AccessoriesCompatible Equipment Cable PlugsMaintenance Safety PrecautionsInput Filter Capacitor Discharge Procedure Routine MaintenanceTroubleshooting HOW to USE Troubleshooting GuideTroubleshooting Field Service Facility Problems TIG WeldingYour local Lincoln Authorized Failures DisplayWiring Diagrams V205-T DC Wiring Diagram forV205-T AC/DC Wiring Diagram for V205-T DC & V205-T AC/DC TIG V205-T DC & V205-T AC/DC TIG Precaucion Warnung