Milwaukee Impact Wrench manual Grounding, Extension Cords

Page 4

GROUNDING

WARNING!

Improperly connecting the grounding wire can result in the risk of electric shock. Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the cord or plug is damaged. If damaged, have it repaired by a MILWAUKEE service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician.

Grounded Tools:

Tools with Three Prong Plugs

Tools marked “Grounding Required”

 

have a three wire cord and three prong

 

grounding plug. The plug must be con-

 

nected to a properly grounded outlet

 

(See Figure A). If the tool should elec-

 

trically malfunction or break down,

 

grounding provides a low resistance

 

path to carry electricity away from the

 

user, reducing the risk of electric

Fig. A

shock.

The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool. The green wire in the cord must be the only wire connected to the tool's grounding system and must never be attached to an electrically “live” terminal.

Your tool must be plugged into an appropriate outlet, properly installed and grounded in accordance with all codes and ordinances. The plug and outlet should look like those in Figure A.

Double Insulated Tools:

Tools with Two Prong Plugs

Tools marked “Double Insulated” do

 

 

not require grounding. They have a

 

 

special double insulation system

 

 

which satisfies OSHA requirements

 

 

and complies with the applicable

 

 

standards of Underwriters Laborato-

 

 

ries, Inc., the Canadian Standard As-

 

 

sociation and the National Electrical

 

 

Code. Double Insulated tools may be

 

 

used in either of the 120 volt outlets

Fig. B

Fig. C

shown in Figures B and C.

 

 

page 4

EXTENSION CORDS

Grounded tools require a three wire extension cord. Double insulated tools can use either a two or three wire extension cord. As the distance from the supply outlet increases, you must use a heavier gauge exten- sion cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool dam- age. Refer to the table shown to determine the required minimum wire size.

The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord. When using more than one extension cord to make up the total length, be sure each cord contains at least the minimum wire size required. If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required mini- mum wire size.

Guidelines for Using Extension Cords

If you are using an extension cord outdoors, be sure it is marked with the suffix “W-A” (“W” in Canada) to indicate that it is acceptable for outdoor use.

Be sure your extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it re- paired by a qualified person before using it.

Protect your extension cords from sharp objects, excessive heat and damp or wet areas.

Recommended Minimum Wire Gauge

for Extension Cords*

Nameplate

 

Extension Cord Length

 

 

 

 

 

 

Amperes

25'

50'

75'

100'

150'

200'

 

 

 

 

 

 

 

0 - 5

16

16

16

14

12

12

5.1

- 8

16

16

14

12

10

--

8.1 - 12

14

14

12

10

--

--

12.1

- 15

12

12

10

10

--

--

15.1

- 20

10

10

10

--

--

--

 

 

 

 

 

 

 

 

*Based on limiting the line voltage drop to five volts at 150% of the rated amperes.

READ AND SAVE ALL INSTRUCTIONS

FOR FUTURE USE.

Image 4
Contents Operators Manual General Safety Rules Read and Understand ALL Instructions Electrical Safety Tool USE and CarePersonal Safety Service Work AreaSpecific Safety Rules Impact Wrench FunctionaldescriptionGrounding Extension CordsAttaching and Removing Accessories Fig Cat. No -20 Tool AssemblyRing Using the Forward/Reverse Switch Fig Cat. No -20, 9092-20, OperationStarting and Stopping the Tool Fig Cat No -20, 9071-20 Impacting TechniquesAccessories MaintenanceFive Year Tool Limited Warranty Conservez CES Instructions Aire DE Travail Sécurité ÉlectriqueSécurité DES Personnes Utilisation ET Entretien DES OutilsRègles DE Sécurité Particulière CLÉ À Percussion Description FonctionnelleCalibres minimaux recommandés pour les Cordons de rallonge Mise À LA Terre AvertissementCordons DE Rallonge Directives pour l’emploi des cordons de rallongeInstallation et retrait des accessoires Fig No de cat -20 Montage DE Loutil AvertissementDémarrage et arrêt de l’outil Fig No de cat -20, 9071-20 Maniement AvertissementTechniques de serrage Maintenance Avertissement Accessoires AvertissementGarantie Limitée DE L’OUTIL DE Cinq ANS NettoyageGuarde Estas Instrucciones Area DE Trabajo Seguridad Electrica USO Y Mantenimiento DE LA HerramientaSeguridad Personal ServicioDescripción Funcional Reglas Especificas DE Seguridad Llave DE ImpactoCat Brocas de berbiquí de Extensiónes Eléctricas Tierra ¡ADVERTENCIAGuías para el uso de cables de extensión Colocación y retiro de accesorios Cat. No -20 Ensamblaje DE LA Herramienta ¡ADVERTENCIAColocación y retiro de accesorios Fig Cat. No -20 Arranque y paro de la herramienta Fig Cat. No -20, 9071-20 Operacion ¡ADVERTENCIATécnicas de impacto Mantenimiento ¡ADVERTENCIA Accesorios ¡ADVERTENCIAGarantía Limitada DE Cinco Años LimpiezaSawdust