Lincoln Electric 455 M manual Negative Electrode Polarity, Voltage Sensing

Page 14

A-4

INSTALLATION

A-4

 

 

 

CABLE INDUCTANCE, AND ITS AFFECT ON PULSE WELDING

For Pulse Welding processes, cable inductance will cause the welding performance to degrade. For the total welding loop length less than 15.24m (50 ft.), tra- ditional welding cables may be used without any effects on welding performance. For the total welding loop length greater than 15.24m (50 ft.), the K1796 Coaxial Welding Cables are recommended. The weld- ing loop length is defined as the total of electrode cable length (A) + work cable length (B) + work length

(C) (See Figure A.3).

 

FIGURE A.3

POWER

 

WAVE

A

 

C

WORK

B

For long work piece lengths, a sliding ground should be considered to keep the total welding loop length less than 15.24m (50 ft.). (See Figure A.4.)

For additional Safety information regarding the elec- trode and work cable set-up, See the standard "SAFE- TY INFORMATION" located in the front of the Instruction Manuals.

CAUTION

Excessive voltage drops caused by poor work piece connections often result in unsatisfactory welding performance.

------------------------------------------------------------------------

NEGATIVE ELECTRODE POLARITY

When negative electrode polarity is required, such as in some Innershield applications, switch the output connections at the power source (electrode cable to the negative (-) stud, and work cable to the positive (+) stud).

When operating with electrode polarity negative the "Electrode Sense Polarity" DIP switch must be set to the "Negative" position on the Wire Drive Feed Head PC Board. The default setting of the switch is positive electrode polarity. Consult the Power Feed instruction manual for further details.

POWER

WAVE

K1796 COAXIAL CABLE

FIGURE A.4

A

 

A

C

WORK

C

B

B

SLIDING WORK CONNECTION

VOLTAGE SENSING

The best arc performance occurs when the Power Waves have accurate data about the arc conditions. Depending upon the process, inductance within the electrode and work lead cables can influence the apparent voltage at the studs of the welder. Voltage sense leads improve the accuracy of the arc conditions

MEASURE FROM END

OF OUTER JACKET OF

CABLE

Output connections on some Power Waves are made via 1/2-13 threaded output studs located beneath the spring loaded output cover at the bottom of the case front.

Most welding applications run with the electrode being positive (+). For those applications, connect the elec- trode cable between the wire feeder and the positive

(+)output stud on the power source (located beneath the spring loaded output cover near the bottom of the case front). Connect the other end of the electrode cable to the wire drive feed plate. The electrode cable lug must be against the feed plate. Be sure the con- nection to the feed plate makes tight metal-to-metal electrical contact. The electrode cable should be sized according to the specifications given in the work cable connections section. Connect a work lead from the negative (-) power source output stud to the work piece. The work piece connection must be firm and secure, especially if pulse welding is planned.

and can have a dramatic effect on performance. Sense Lead Kits (K940-10, -25 or -50) are available for this purpose.

CAUTION

If the voltage sensing is enabled but the sense leads are missing, improperly connected, or if the electrode polarity switch is improperly configured, extremely high welding outputs may occur.

------------------------------------------------------------------------

The ELECTRODE sense lead (67) is built into the con- trol cable, and is automatically enabled for all semi- automatic processes. The WORK sense lead (21) con- nects to the Power Wave 455M (CE) at the four pin connector located underneath the output stud cover. By default the WORK voltage is monitored at the out- put stud in the Power Wave 455M (CE). For more information on the WORK sense lead (21), see "Work Voltage Sensing” in the following paragraph.

All constant current processes sense the voltage at the output studs of the Power Wave 455M (CE) by default.

POWER WAVE 455M (CE)

Image 14
Contents Power Wave 455 M Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcSafety Safety Thank You Table of Contents Section F-1 Section EThru E-6 Section F-2 Installation Technical Specifications Power Wave 455M CE K2202-2Lifting Machine GroundingHigh Frequency Protection StackingTable A.1 Input Fuse and Supply Wire ConsiderationsInput Connection Cable INDUCTANCE, and ITS Affect on Pulse Welding Negative Electrode PolarityVoltage Sensing Electrode Voltage Sensing System DescriptionTable A.2 Single Head Boom Feeder Configuring the SystemSingle Head Feeder UP to 4 Feeders AllowedDual Head Boom Feeder using two single heads Welding with Multiple Power Waves Control Cable SpecificationsInstallation Control Board DIP Switch Receptacle SpecificationsDIP Switch Settings and Locations Water Flow SensorSafety Precautions 1OPERATIONB-1Power Wave 455M CE Operation Definition of Welding TermsRequired Equipment General DescriptionRecommended Processes and Equipment LimitationsCase Front Controls Figure B.1Welding Adjustments Nominal ProceduresFringe Procedures Making a WeldARC Control Welding ModeConstant Voltage Welding Pulse Welding Figure A.6 Current Wave Form PulseField Installed AccessoriesFactory Installed Optional EquipmentMaintenance Routine MaintenanceTroubleshooting HOW to USE Troubleshooting GuideUsing the Status LED to Troubleshoot System Problems Error code before the machine is turned offError Codes for the Power Wave Error Code # IndicationAuthorized Field Service Facility Contact your local LincolnPower Feed System Using Status LED section of this text Cabling, etc Verify weld mode is correct for Power Wave 455M CE Wiring Diagram Connection Diagram Connection Diagram Semi-automatic Simple SystemDiagrams Dimension Print Power Wave 455MPrecaucion Warnung