Wagner SprayTech GM 2000 EACF Replacing AirCoat flat jet tips, Cleaning of AirCoat flat jet tips

Page 19

GM 2000 EAC - EN

4.7

Replacing AirCoat flat jet tips

 

 

 

 

 

1.

Switch off control unit.

 

 

 

 

 

2.

Relieve spray gun and system

I

H

 

 

 

 

pressure!

 

 

 

 

 

 

 

 

 

3.

Lock spray gun. Turn locking screw

 

 

 

 

 

 

clockwise until stop. (look in spray-

 

 

 

 

 

 

ing direction)

 

 

 

 

 

4.

Unsrew cap ring (I) and remove air

 

 

 

 

 

 

cap (H).

 

 

 

 

 

5.

Remove AirCoat tip insert (F) and

 

X

F G

E

 

 

brush cleaning solvent until all tra-

 

 

 

 

 

 

ces of paint are dissolved.

 

 

 

 

 

 

Handle the hard metal tip insert (C) with care. Do not clean it with sharp metal ob-

 

 

jects.

 

 

 

 

6.Assembly: Fit tip insert (F) on paint channel (G).

7.Fit air cap (H) onto fan nozzle (F); make sure that the pins in the air cap fit into the grooves in the tip.

8.Fit cap ring (I) with air cap (H) onto spray gun body (E).

9.Adjust desired jet level by means of air cap horns (X) and tighten cap ring (I) by hand.

4.8Cleaning of AirCoat flat jet tips

For disassembly and assembly see of AirCoat nozzles chapter 4.7.

The AirCoat nozzle (F) can be placed into a cleaning solvent which has been recommended by the paint manufacturer. Do not treat the hard metal on the AirCoat nozzle using sharp edged objects.

4.9Clogging of AirCoat flat jet tips

For blockages in the AirCoat flat jet tip the accessory - tip cleaning device - is available with the partnumber 0139 014.

This tip cleaning device can be used together with the GM 2000 EAC to flush out blocked AirCoat flat jet tips in the opposite direction to the usual spray direction.

4.3

Image 19
Contents Operating Manual Page GM 2000 EAC EN ContentsSpare Parts Catalogue Introduction Using the manualSafety Safety RegulationsEarthing Accessories and spare partsSafety information on harmless electrostatic discharges Protective breathing masksPTB Conformity certification Months / 6 months for multi-shift operation Important notes on product liabilityEMC test CE Conformity0179 Short explanation CE = Communauté EuropéenneDescription Technical dataFunctional description Activated and material valve open AirCoat round jet process Electrostatic effect What kind of spraying material can be applied?Imperfect earthing of a workpiece will result Preparation Before Starting WorkPreparation of paint EarthingEmpty For flat jet process Adjusting round jet fanStarting WORK, and Handling PreparationExchange of Aircoat round jet tip insert EAC round Cleaning of clogged round jet tipsChanging from AirCoat round jet to AirCoat flat jet Replacing AirCoat flat jet tips Cleaning of AirCoat flat jet tipsClogging of AirCoat flat jet tips Empty If the flat jet nozzle is fitted MaintenanceDecommissioning and cleaning If the round jet nozzle is fittedExchange or cleaning of filters Dissassembly of AirCoat nozzle body round jetExchange of complete valve rod, or of valve rod seals Adjustment of the valve rod sealExchange of paint channel Problem Cause Solution Trouble Shooting and SolutionsEmpty Part-No Marking Volume flow Jet width Recommended filter AccessoriesRound jet tip inserts AirCoat flat tips Description Long filter housing and and filtersHoses and fittings Special toolsEmpty Part No., description and quantity How to order spare parts?Special marks in spare parts lists Spare Parts CatalogueQuantity Description Spare parts listGM 2000 EAC EN Empty Page CH- 9450 Altstätten England / United KingdomDeutschland / Germany Schweiz / Switzerland