Wagner SprayTech GM 2000 EACF, GM 2000 EACR manual Adjustment of the valve rod seal

Page 23

GM 2000 EAC - EN

5.4Adjustment of the valve rod seal

In case paint leaks at the valve rod near the trigger:

1.Pull trigger and throughly

clean paint channel with solvent.

2.Tighten the sealing screw (A) ca- refully with universal spanner

3.If leaking continues, see chapter 5.5.

A

5.5Exchange of complete valve rod, or of valve rod seals

1.Pull trigger (Y) and unscrew locking nut (X); remove compres- sion spring.

2.Remove flat-head screw (Z) and take off trigger (Y).

3.Unscrew sealing screw (4/B) from sealing sleeve (5).

4.Carefully remove complete valve rod at surface (F) and replace. To replace seals:

5.Hold with universal spanner at surface (E) and unscrew valve sealing element (1/A) using uni- versal pliers.

X

Z

Y

1

2

3

4

5

6

7

8

 

9

 

Loctite 243

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loctite 243

 

E

 

A

 

 

B

 

C

 

 

D

F

 

 

 

 

 

 

6.Remove compression ring (2) and packing (3).

7.Hold with spanner at surface (D) and unscrew at surface (C), removing push-rod cap (7).

8.Exchange compression ring (with O-ring) (2), front seal (3), rear seal (4), push-rod seal (8) and replace air valve seal (9) of the air valve.

9.Reassemble in reverse order and secure thread with Loctite 243.

10.Place locking nut (X) with compression spring in position. Actuate trigger (Y) and tighten the locking nut (X) until a noticeable resistance is felt.

5.3

Image 23
Contents Operating Manual Page GM 2000 EAC EN ContentsSpare Parts Catalogue Introduction Using the manualSafety Safety RegulationsEarthing Accessories and spare partsSafety information on harmless electrostatic discharges Protective breathing masksPTB Conformity certification Months / 6 months for multi-shift operation Important notes on product liabilityEMC test CE Conformity0179 Short explanation CE = Communauté EuropéenneFunctional description Technical dataDescription Activated and material valve open AirCoat round jet process Electrostatic effect What kind of spraying material can be applied?Imperfect earthing of a workpiece will result Preparation Before Starting WorkPreparation of paint EarthingEmpty For flat jet process Adjusting round jet fanStarting WORK, and Handling PreparationChanging from AirCoat round jet to AirCoat flat jet Cleaning of clogged round jet tipsExchange of Aircoat round jet tip insert EAC round Clogging of AirCoat flat jet tips Cleaning of AirCoat flat jet tipsReplacing AirCoat flat jet tips Empty If the flat jet nozzle is fitted MaintenanceDecommissioning and cleaning If the round jet nozzle is fittedExchange or cleaning of filters Dissassembly of AirCoat nozzle body round jetExchange of complete valve rod, or of valve rod seals Adjustment of the valve rod sealExchange of paint channel Problem Cause Solution Trouble Shooting and SolutionsEmpty Round jet tip inserts AccessoriesPart-No Marking Volume flow Jet width Recommended filter AirCoat flat tips Description Long filter housing and and filtersHoses and fittings Special toolsEmpty Part No., description and quantity How to order spare parts?Special marks in spare parts lists Spare Parts CatalogueQuantity Description Spare parts listGM 2000 EAC EN Empty Page CH- 9450 Altstätten England / United KingdomDeutschland / Germany Schweiz / Switzerland