Wagner SprayTech GM 2000 EACR, GM 2000 EACF manual Cleaning of clogged round jet tips

Page 18

GM 2000 EAC - EN

4.4Cleaning of clogged round jet tips

1.By means of tip spanner (A), loosen tip insert (B) by a half turn.

2.Remove tip spanner and briefly pull trigger. Caution, never spray into an enclosed vessel.

3.After cleaning the tip retighten.

A

B

4.5Exchange of Aircoat round jet tip insert (EAC round)

1.Remove tip insert (B) with tip span- ner (A).

2.Fit desired tip insert (acc. to table 7.1) with tip spanner.

B

A

4.6Changing from AirCoat round jet to AirCoat flat jet.

1.Replace paint with cleaning sol- vent, actuate trigger, and thorough- ly rinse paint channel.

2.Relieve spray gun and system pressure.

3.Lock spray gun. Turn locking screw clockwise until stop. (Look in spray- ing direction)

4.Unscrew tip nut (C).

5.Remove tip body (D) by means of pin wrench.

6.Fit tip insert (F) on paint channel

(G).

7.Fit air cap (H) onto fan nozzle (F); make sure that the pins in the air cap fit into the grooves in the flat nozzle.

8.Fit cap ring (I) with air cap (H) onto spray gun body (E).

9.Adjust desired jet level by means of air cap horns (X) and tighten cap ring (I) by hand.

Universal spanner

C

DE

I H

X F G E

4.2

Image 18
Contents Operating Manual Page Contents GM 2000 EAC ENSpare Parts Catalogue Using the manual IntroductionSafety Regulations SafetyProtective breathing masks Accessories and spare partsSafety information on harmless electrostatic discharges EarthingPTB Conformity certification Important notes on product liability Months / 6 months for multi-shift operationShort explanation CE = Communauté Européenne CE Conformity0179 EMC testTechnical data DescriptionFunctional description Activated and material valve open AirCoat round jet process What kind of spraying material can be applied? Electrostatic effectEarthing Preparation Before Starting WorkPreparation of paint Imperfect earthing of a workpiece will resultEmpty Preparation Adjusting round jet fanStarting WORK, and Handling For flat jet processCleaning of clogged round jet tips Exchange of Aircoat round jet tip insert EAC roundChanging from AirCoat round jet to AirCoat flat jet Cleaning of AirCoat flat jet tips Replacing AirCoat flat jet tipsClogging of AirCoat flat jet tips Empty If the round jet nozzle is fitted MaintenanceDecommissioning and cleaning If the flat jet nozzle is fittedDissassembly of AirCoat nozzle body round jet Exchange or cleaning of filtersAdjustment of the valve rod seal Exchange of complete valve rod, or of valve rod sealsExchange of paint channel Trouble Shooting and Solutions Problem Cause SolutionEmpty Accessories Part-No Marking Volume flow Jet width Recommended filterRound jet tip inserts AirCoat flat tips Special tools Long filter housing and and filtersHoses and fittings DescriptionEmpty Spare Parts Catalogue How to order spare parts?Special marks in spare parts lists Part No., description and quantitySpare parts list Quantity DescriptionGM 2000 EAC EN Empty Page Schweiz / Switzerland England / United KingdomDeutschland / Germany CH- 9450 Altstätten