4.4Cleaning of clogged round jet tips
1.By means of tip spanner (A), loosen tip insert (B) by a half turn.
2.Remove tip spanner and briefly pull trigger. Caution, never spray into an enclosed vessel.
3.After cleaning the tip retighten.
A
B
4.5Exchange of Aircoat round jet tip insert (EAC round)
1.Remove tip insert (B) with tip span- ner (A).
2.Fit desired tip insert (acc. to table 7.1) with tip spanner.
B |
A |
4.6Changing from AirCoat round jet to AirCoat flat jet.
1.Replace paint with cleaning sol- vent, actuate trigger, and thorough- ly rinse paint channel.
2.Relieve spray gun and system pressure.
3.Lock spray gun. Turn locking screw clockwise until stop. (Look in spray- ing direction)
4.Unscrew tip nut (C).
5.Remove tip body (D) by means of pin wrench.
6.Fit tip insert (F) on paint channel
(G).
7.Fit air cap (H) onto fan nozzle (F); make sure that the pins in the air cap fit into the grooves in the flat nozzle.
8.Fit cap ring (I) with air cap (H) onto spray gun body (E).
9.Adjust desired jet level by means of air cap horns (X) and tighten cap ring (I) by hand.
Universal spanner
C
DE
I H
X F G E
4.2