6. TROUBLE SHOOTING AND SOLUTIONS

 

 

Problem

 

Cause

 

Solution

 

 

 

 

 

 

 

 

 

 

Insufficient material

•

Tip too small

•

Select larger tip (see chapter

 

 

output

 

 

 

7.1 and 7.2)

 

 

 

•

Material pressure too low

•

Increase material pressure

 

 

 

•

Gun filter or high-pressure

•

Clean or exchange filter

 

 

 

 

filter in pump blocked

 

 

 

 

 

 

•

AirCoat tip (round) clogged

•

Clean tip (see chapter 4.4,

 

 

 

 

 

 

4.8 and 4.9)

 

 

 

 

 

 

 

 

 

 

Poor spray pattern

•

Wrongly adjusted atomizing

•

Readjust the atomizing air

 

 

 

 

air

 

 

 

 

 

 

•

Tip too large

•

Select smaller tip (see chap-

 

 

 

 

 

 

ter 7.1 and 7.2)

 

 

 

•

Material pressure too low

•

Increase material pressure

 

 

 

•

Material viscosity too high

•

Thin material acc. to manu-

 

 

 

 

 

 

facturer's instruction.

 

 

 

 

 

 

 

 

 

 

Leaking air valve

•

Damaged seals on the valve

•

Exchange seals (see chapter

 

 

 

 

rod

 

5.4 and 5.5)

 

 

 

 

 

 

 

 

 

 

Poor wrap round or

•

Poor earth

•

Check earth of object

 

 

electrostatic effect

 

 

 

 

 

 

 

 

•

Paint conductivity too high /

•

Check resistance of paint

 

 

 

 

resistance paint too high

 

(see chapter 2.4)

 

 

 

•

Spraying pressure too high

•

Adjust spraying pressure

 

 

 

 

 

 

 

 

 

 

Back spraying

•

No earth

•

Check earth. (see chapter

 

 

 

 

 

 

3.2)

 

 

 

 

•

Distance between spray gun

•

Reduce distance between

 

 

 

 

and workpiece too large.

 

spray gun and workpiece.

 

 

 

 

 

 

 

 

 

No electrostatic ef-

•

High voltage switched off ?

•

Switch on high voltage.

 

 

fect

 

 

 

 

 

 

 

(no wrap around)

•

High voltage failure

•

Repair failure acc. to opera-

 

 

 

 

 

 

ting instructions of control

 

 

 

 

 

 

unit.

 

 

 

 

 

 

 

 

6.1

Image 25
Contents Operating Manual Page GM 2000 EAC EN ContentsSpare Parts Catalogue Introduction Using the manualSafety Safety RegulationsSafety information on harmless electrostatic discharges Accessories and spare partsProtective breathing masks EarthingPTB Conformity certification Months / 6 months for multi-shift operation Important notes on product liability0179 CE ConformityShort explanation CE = Communauté Européenne EMC testDescription Technical dataFunctional description Activated and material valve open AirCoat round jet process Electrostatic effect What kind of spraying material can be applied?Preparation of paint Preparation Before Starting WorkEarthing Imperfect earthing of a workpiece will resultEmpty Starting WORK, and Handling Adjusting round jet fanPreparation For flat jet processExchange of Aircoat round jet tip insert EAC round Cleaning of clogged round jet tipsChanging from AirCoat round jet to AirCoat flat jet Replacing AirCoat flat jet tips Cleaning of AirCoat flat jet tipsClogging of AirCoat flat jet tips Empty Decommissioning and cleaning MaintenanceIf the round jet nozzle is fitted If the flat jet nozzle is fittedExchange or cleaning of filters Dissassembly of AirCoat nozzle body round jetExchange of complete valve rod, or of valve rod seals Adjustment of the valve rod sealExchange of paint channel Problem Cause Solution Trouble Shooting and SolutionsEmpty Part-No Marking Volume flow Jet width Recommended filter AccessoriesRound jet tip inserts AirCoat flat tips Hoses and fittings Long filter housing and and filtersSpecial tools DescriptionEmpty Special marks in spare parts lists How to order spare parts?Spare Parts Catalogue Part No., description and quantityQuantity Description Spare parts listGM 2000 EAC EN Empty Page Deutschland / Germany England / United KingdomSchweiz / Switzerland CH- 9450 Altstätten