Wagner SprayTech GM 2000 EACF Preparation Before Starting Work, Preparation of paint, Earthing

Page 15

GM 2000 EAC - EN

3. PREPARATION BEFORE STARTING WORK

Caution

The operating instructions and the safety regulations for the additional system components used must be read before starting-up .

This spray gun must be used a part of an AirCoat-Electrostatic spraying system.

The control units VM 200 EN, VM 2000 EN or EPP 200 EN and other various components are also needed (see Wagner-accesories).

The spray gun and paint supply system must be flushed out with a suitable cleaning solvent before being used.

3.1Preparation of paint

The viscosity of the paints is of great importance. The best results are obtained with paints between 18 and 30 DIN sec. (measured in immersion flow cup DIN 4 mm). In most cases, the application of paints of up to 50-60 DIN sec. for thick layers does not cause problems.

3.2Earthing

Perfect earthing is a prerequisite for optimum coating efficiency and safety.

The imperfect earthing of a workpiece will result in:

Sparks between the object being sprayed and the suspension hook.

Insufficient electrostatic effect (no wrap-around)

Uneven coating thickness

Back spraying to spray gun and sprayer

The prerequisites for perfect earthing and coating are:

Clean workpiece suspension.

Earthing of spraying cabin, conveyor system and suspension with 10mm2 copper cable to system earth, earthing strip or ring.

Earthing of all conductive parts within the working area.

The earthing resistance of the workpiece may not exceed 1 MΩ.

conveyor

Control unit

Object to be

sprayed

Pump

R max < 1 M

Spraying stand

Paint container

Floor, conductive

3.1

Image 15
Contents Operating Manual Page GM 2000 EAC EN ContentsSpare Parts Catalogue Introduction Using the manualSafety Safety RegulationsEarthing Accessories and spare partsSafety information on harmless electrostatic discharges Protective breathing masksPTB Conformity certification Months / 6 months for multi-shift operation Important notes on product liabilityEMC test CE Conformity0179 Short explanation CE = Communauté EuropéenneTechnical data DescriptionFunctional description Activated and material valve open AirCoat round jet process Electrostatic effect What kind of spraying material can be applied?Imperfect earthing of a workpiece will result Preparation Before Starting WorkPreparation of paint EarthingEmpty For flat jet process Adjusting round jet fanStarting WORK, and Handling PreparationCleaning of clogged round jet tips Exchange of Aircoat round jet tip insert EAC roundChanging from AirCoat round jet to AirCoat flat jet Cleaning of AirCoat flat jet tips Replacing AirCoat flat jet tipsClogging of AirCoat flat jet tips Empty If the flat jet nozzle is fitted MaintenanceDecommissioning and cleaning If the round jet nozzle is fittedExchange or cleaning of filters Dissassembly of AirCoat nozzle body round jetExchange of complete valve rod, or of valve rod seals Adjustment of the valve rod sealExchange of paint channel Problem Cause Solution Trouble Shooting and SolutionsEmpty Accessories Part-No Marking Volume flow Jet width Recommended filterRound jet tip inserts AirCoat flat tips Description Long filter housing and and filtersHoses and fittings Special toolsEmpty Part No., description and quantity How to order spare parts?Special marks in spare parts lists Spare Parts CatalogueQuantity Description Spare parts listGM 2000 EAC EN Empty Page CH- 9450 Altstätten England / United KingdomDeutschland / Germany Schweiz / Switzerland