Friedrich ZQ05B10, ZQ07B10 manual Preface, Features, Specifications

Page 3

1. PREFACE

This service manual provides various service information, including the mechanical and electrical parts, etc. This room air conditioner was manufactured and assembled under a strict quality control system.

The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.

1.1 FEATURES

DESIGNED FOR COOLING ONLY

POWERFUL AND INCREDIBLE COOLING

TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE

BUILT-IN ADJUSTABLE THERMOSTAT

WASHABLE ONE-TOUCH FILTER

COMPACT SIZE

1.2 SPECIFICATIONS

MODELS

ZQ05B10

 

ZQ07B10

ITEMS

 

 

 

 

COOLING CAPACITY (BTU/h)

5,100

 

6,500

 

 

 

 

POWER SUPPLY (Phase, V, Hz)

 

1ø, 115V, 60HZ

 

 

 

 

INPUT (W)

540

 

670

 

 

 

 

OPERATING CURRENT (AMP.)

5.0

 

6.1

 

 

 

 

REFRIGERANT CONTROL

 

CAPILLARY TUBE

 

 

 

 

REFRIGERANT CHARGE (R-22)

325g (7.9 oz)

 

335g (11.8 oz)

 

 

 

 

INSIDE FAN

 

TURBO FAN

 

 

 

OUTSIDE FAN

PROPELLER FAN WITH SLINGER RING

 

 

 

AIR DISCHARGE

2-WAY (RIGHT AND LEFT)

 

 

 

 

CHASSIS

 

TOP-DOWN

 

 

 

PROTECTOR

• OVERLOAD PROTECTOR FOR COMPRESSOR

• INTERNAL PROTECTOR FOR FAN MOTOR

 

 

 

 

 

TEMPERATURE CONTROL

 

THERMISTOR

 

 

 

 

FAN MOTOR

6 POLES, 16W

 

6 POLES, 27W

 

 

 

 

—3—

Image 3
Contents Room Air Conditioner Service and Parts Manual ZStar Contents Features SpecificationsPreface Safety Precautions Locations of ControlsInsulation Resistance Test Cabinet Disassembly InstructionsMechanical Parts Front GrilleAIR Handling Parts AIR Guide UpperORIFICE, Turbo FAN and FAN Electrical Parts AIR GuideOverload Protector Thermostat Rotary SwitchCompressor CapacitorPower Cord Refrigerant CycleCondenser Capillary Tube EVAPORATOR/CONDENSERPulling Vacuum Outside Dimensions unit mm Troubleshooting GuideCondenser Coils Piping SystemUnit is running but cooling is ineffective Troubleshooting GuideFails to Start Room AIR Conditioner Voltage Limits Check for continuity Refer to Complaint Cause Remedy Model ZQ05B10,ZQ07B10 Circuit DiagramExploded View ZQ05B10 Service Parts ListZQ07B10 Memo Use Factory Certified Parts