Friedrich ZQ05B10, ZQ07B10 manual Electrical Parts, AIR Guide, Overload Protector

Page 7

2.2.3 MOTOR

1.Disconnect the unit from the power source.

2.Remove the front grille. (Refer to Section 2.1.1)

3.Remove the cabinet. (Refer to Section 2.1.2)

4.Remove the control panel. (Refer to Section 2.1.3)

5.Remove the air guide upper. (Refer to Section 2.2.1)

6.Remove the compressor, turbo fan, fan and shroud. (Refer to Section 2.2.2)

7.Remove 2 screws that secure the motor to the motor. (See Figure 10)

8.Remove the motor.

9.Re-install by referring to the procedures above.

2.2.4 AIR GUIDE

1.Disconnect the unit from the power source.

2.Remove the front grille. (Refer to Section 2.1.1)

3.Remove the cabinet. (Refer to Section 2.1.2)

4.Remove the control panel. (Refer to Section 2.1.3)

5.Remove the air guide upper. (Refer to Section 2.2.1)

6.Remove the compressor, turbo fan, fan and shroud. (Refer to Section 2.2.2)

7.Remove the motor. (Refer to Section 2.2.3)

8.Remove 2 screws that secure the air guide to the base pan. (See Figure 11)

9.Push the air guide backward and lift it upward. (See Figure 11)

10.Re-install by referring to the procedures above.

2.3ELECTRICAL PARTS

2.3.1 OVERLOAD PROTECTOR

1.Remove the front grille and cabinet. (Refer to Section 2.1)

2.Remove the nut which fastens the terminal cover.

3.Remove the terminal cover.

4.Remove all the leads from the overload protector.

5.Remove the overload protector.

6.Re-install the components by referring to the removal procedure above.

(See Figure 12 and 13)

Figure 10

Figure 11

Figure 12

Figure 13

 

— 7—

Image 7
Contents Room Air Conditioner Service and Parts Manual ZStar Contents Specifications FeaturesPreface Locations of Controls Safety PrecautionsInsulation Resistance Test Cabinet Disassembly InstructionsMechanical Parts Front GrilleAIR Guide Upper AIR Handling PartsORIFICE, Turbo FAN and FAN AIR Guide Electrical PartsOverload Protector Thermostat Rotary SwitchCompressor CapacitorRefrigerant Cycle Power CordCondenser Capillary Tube EVAPORATOR/CONDENSERPulling Vacuum Outside Dimensions unit mm Troubleshooting GuideCondenser Coils Piping SystemUnit is running but cooling is ineffective Troubleshooting GuideFails to Start Room AIR Conditioner Voltage Limits Check for continuity Refer to Complaint Cause Remedy Model ZQ05B10,ZQ07B10 Circuit DiagramExploded View ZQ05B10 Service Parts ListZQ07B10 Memo Use Factory Certified Parts