Friedrich ZQ07B10, ZQ05B10 manual Troubleshooting Guide, Unit is running but cooling is ineffective

Page 14

3.3 TROUBLESHOOTING GUIDE

In general, possible trouble is classified in two categories.

The one is called Starting Failure which is caused by an electrical defect. The other is Ineffective Air Con- ditioning caused by a defect in the refrigeration circuit and/or improper application.

Unit is running but cooling is ineffective.

Ineffective Cooling

Check cold air circulation for smooth flow.

Dirty indoor coil (heat exchanger)

Malfunction of fan.

Clogging of air filter.

Obstruction at air outlet.

Remove obstruction.

Check clogging in refrigera- tion circuit.

Repair clogging in refrigeration circuit.

Check outdoor coil (heat exchanger) and fan operation.

Check gas leakage.

Repair gas leak.

Replacement of unit if the unit is beyond repair.

Satisfactory operation with temperature difference of inlet & outlet air: 55~59°F (13~15°C)

Check heat load increase.

Clean condenser.

Not on separate circuit

Check inside gas pressure.

Adjust refrigerant charge.

Malfunction of compressor.

Replacement of compressor.

— 14—

Image 14
Contents Room Air Conditioner Service and Parts Manual ZStar Contents Preface FeaturesSpecifications Insulation Resistance Test Safety PrecautionsLocations of Controls Front Grille Disassembly InstructionsMechanical Parts CabinetORIFICE, Turbo FAN and FAN AIR Handling PartsAIR Guide Upper Overload Protector Electrical PartsAIR Guide Capacitor Rotary SwitchCompressor ThermostatCondenser Power CordRefrigerant Cycle EVAPORATOR/CONDENSER Capillary TubePulling Vacuum Troubleshooting Guide Outside Dimensions unit mmPiping System Condenser CoilsTroubleshooting Guide Unit is running but cooling is ineffectiveFails to Start Room AIR Conditioner Voltage Limits Check for continuity Refer to Complaint Cause Remedy Circuit Diagram Model ZQ05B10,ZQ07B10Exploded View Service Parts List ZQ05B10ZQ07B10 Memo Use Factory Certified Parts