Friedrich ZQ05B10, ZQ07B10 manual Disassembly Instructions, Mechanical Parts, Front Grille, Cabinet

Page 5

2. DISASSEMBLY INSTRUCTIONS

2.1 MECHANICAL PARTS

2.1.1 FRONT GRILLE

1.Disconnect the unit from source of power.

2.Remove the two knobs by pulling them off. Using a screwdriver, remove the screw that secures the front grille to control board.

(See Figure 1)

3.Push the front grille up from the bottom. Pull the top of the front grille away from the cabinet as the top tabs lift out of their slots. (See Figure 2)

4.Replace the grille by placing the tabs in the slots and push the grille until it snaps into place.

Figure 1

Figure 2

2.1.2 CABINET

1. Disconnect the unit from the power source.

2. Remove the front grille. (Refer to section 2.1.1)

3. Remove 9 screws that secure the cabinet to the base pan and condenser. (See Figure 3)

4. Lift the cabinet from the unit.

Figure 3

5. Re-install by referring to the procedures above.

2.1.3 CONTROL PANEL

1.Disconnect the unit from the power source.

2.Remove the front grille. (Refer to Section 2.1.1)

3.Remove the cabinet. (Refer to Section 2.1.2)

4.Remove 2 screws that secure the control board to base pan and air guide. (See Figure 4)

5.Pull the control board toward yourself.

NOTE : Controls, wires, and capacitor are now accessible for servicing. Discharge the capacitor before servicing. See step

2.3.3on page 8 for procedures.

6.Disconnect one housing terminal and 3 wires for the fan motor and compressor. (See Figure 5)

7.Re-install components by referring to procedures above. (Refer to wiring diagram on page 23 in this manual or inside control board.)

Figure 4

Figure 5

— 5—

Image 5
Contents Room Air Conditioner Service and Parts Manual ZStar Contents Preface FeaturesSpecifications Insulation Resistance Test Safety PrecautionsLocations of Controls Mechanical Parts Disassembly InstructionsFront Grille CabinetORIFICE, Turbo FAN and FAN AIR Handling PartsAIR Guide Upper Overload Protector Electrical PartsAIR Guide Compressor Rotary SwitchCapacitor ThermostatCondenser Power CordRefrigerant Cycle Capillary Tube EVAPORATOR/CONDENSERPulling Vacuum Outside Dimensions unit mm Troubleshooting GuideCondenser Coils Piping SystemUnit is running but cooling is ineffective Troubleshooting GuideFails to Start Room AIR Conditioner Voltage Limits Check for continuity Refer to Complaint Cause Remedy Model ZQ05B10,ZQ07B10 Circuit DiagramExploded View ZQ05B10 Service Parts ListZQ07B10 Memo Use Factory Certified Parts