2.2 AIR HANDLING PARTS

2.2.1 AIR GUIDE UPPER

1.

Disconnect the unit from the power source.

2.

Remove the front grille. (Refer to Section 2.1.1)

3.Remove the cabinet. (Refer to Section 2.1.2)

4.Remove the control panel. (Refer to Section 2.1.3)

5.Remove 2 screws that secure the air guide upper to air guide lower. (See Figure 6)

6.Lift air guide upper upward.

7.Re-install by referring to the procedures above.

2.2.2 ORIFICE, TURBO FAN AND FAN

1.Disconnect the unit from the power source.

2.Remove the front grille. (Refer to Section 2.1.1)

3.Remove the cabinet. (Refer to Section 2.1.2)

4.Remove the control panel (Refer to Section 2.1.3)

5.Remove the air guide upper. (Refer to Section 2.2.1)

6.Remove 2 screws that secure the base pan to condenser. (See Figure 7)

7.Remove screw that secures the shroud to channel of condenser.

8.Press the snap area of shroud with your thumbs. This allows you to remove it from the condenser.

9.Lift the compressor upward with the evaporator and condenser. (See Figure 7)

10.Remove the orfice by pushing the snap area of the air guide blower. (See Figure 8)

11.Remove the clamp springs which are clamped to the base of fan and turbo fan by hand plier. (See Figure 9)

12.Pull the fan and turbo fan outward.

13.Remove the shroud.

14.Re-install by referring to the procedures above.

Figure 6

Figure 7

Figure 8

Figure 9

— 6—

Image 6
Contents Room Air Conditioner Service and Parts Manual ZStar Contents Features SpecificationsPreface Safety Precautions Locations of ControlsInsulation Resistance Test Front Grille Disassembly InstructionsMechanical Parts CabinetAIR Handling Parts AIR Guide UpperORIFICE, Turbo FAN and FAN Electrical Parts AIR GuideOverload Protector Capacitor Rotary SwitchCompressor ThermostatPower Cord Refrigerant CycleCondenser EVAPORATOR/CONDENSER Capillary TubePulling Vacuum Troubleshooting Guide Outside Dimensions unit mmPiping System Condenser CoilsTroubleshooting Guide Unit is running but cooling is ineffectiveFails to Start Room AIR Conditioner Voltage Limits Check for continuity Refer to Complaint Cause Remedy Circuit Diagram Model ZQ05B10,ZQ07B10Exploded View Service Parts List ZQ05B10ZQ07B10 Memo Use Factory Certified Parts