Craftsman 919.16732 owner manual Extension Cords, Voltage and Circuit Protection

Page 11

Extension Cords

Using extension cords is not recom- mended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and over- heating.

Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as needed.

If an extension cord must be used, be sure it is:

a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product

in good condition

no longer than 50 feet

12 gauge (AWG) or larger. (Wire size increases as gauge number decreases. 10 AWG and 8 AWG may also be used. DO NOT USE 14 OR 16 AWG.)

Voltage and Circuit Protection

Refer to the specification chart for the voltage and minimum branch circuit requirements.

Certain air com- pressors can be

operated on a 15 amp circuit if the following conditions are met.

1.Voltage supply to circuit must comply with the National Electrical Code.

2.Circuit is not used to supply any other electrical needs.

3.Extension cords comply with specifications.

4.Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse. NOTE: If com- pressor is connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses should be marked "D" in Canada and "T" in the US.

If any of the above conditions can- not be met, or if operation of the compressor repeatedly causes inter- ruption of the power, it may be nec- essary to operate it from a 20 amp circuit. It is not necessary to change the cord set.

11- ENG

A10819

Image 11
Contents AIR Compressor Table of Contents Important Safety Instructions Specification ChartSafety Guidelines Definitions Always remain in attendance with What Could HappenAttachments & Accessories Personnel can result in serious injury Safety equipment must be properlyElectricity. Like any other electrically Repairs attempted by unqualifiedHazard Warning Risk from Moving Parts Result in serious burns How To Prevent It Equip area of operation with a fire extinguisher Keep children away from the air compressor at all timesDuty Cycle AccessoriesAccessories GlossaryLocation of the Air Compressor AssemblyInstallation UnpackingVoltage and Circuit Protection Extension CordsRegulator OperationKnow Your Air Compressor Description of OperationAir Compressor Pump not shown How to StopBefore Starting Before Each Start-Up How to StartTo Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesAir Filter Air Filter Inspection ReplacementAir Compressor Pump Intake and Exhaust Valves Tube Service and AdjustmentsTo Replace or Clean Check Valve Outlet Tube Nut Pressure ReliefTo Replace Regulator Storage Troubleshooting Being used Check wiring connection ENG A10819 Garantía Total DE UN AÑO DEL Compresor DE Aire ContenidoGarantía Lesiones serias Definiciones DE Normas DE SeguridadModelo Nº 919.167320¿Cómo prevenirlo? Instrucciones Importantes DE SeguridadGuarde Estas Instrucciones ¿Qué puede occurrir? ¿Cómo prevenirlo? Advertencia Riesgo de ExplosiónAdvertencia Riesgo de Inhalación ¿Qué puede occurrir? Advertencia Riesgo de Caída ¿Qué puede occurrir? Advertencia Riesgo de Quemaduras ¿Qué puede occurrir?Advertencia Riesgo de Partes Móviles ¿Qué puede occurrir? Conservar Estas Instrucciones Accesorios GlosarioAccesorios Ciclo DE ServicioCómo Preparar LA Unidad Ubicación del compresor de aire EnsambladoInstalación DesempaqueProtección del voltaje y del circuito Cables de extensión eléctricaPara referencias futuras OperaciónConozca su compresor de aire Descripción de operacionesProcedimiento para el asentamiento Cómo utilizar su unidadAntes de poner en marcha Cómo detenerlaCómo poner en marcha Antes de cada puesta en marchaCómo drenar el tanque MantenimientoResponsabilidades del cliente Cómo verificar la válvula de seguridadFiltro de aire Filtro de Aire Inspección y reemplazoDe presión Servicio Y AjustesPara reemplazar o limpiar la válvula de retención Tubo de Tuerca Salida Tubo aliviadorNiple Para reemplazar el reguladorRegulador RápidoAlmacenaje Problema Causa Corrección Guía DE Diagnóstico DE ProblemasSe utiliza un Pintura por rociado. Vea la 49- SP A10819 A10819 50- SP Contratos de Protección para Reparaciones  Product replacement if your covered product cant be fixedRepair Protection Agreements SU-HOGARSM MY-HOMESears Parts and Repair Center Canada