MAINTENANCE

Customer Responsibilities

Before

Daily

each

or after

each

use

use

 

Every

100Yearly

hours

Check Safety Valve

 

Drain Tank

 

Air Filter

1

 

Air compressor pump intake

 

and exhaust valves

 

 

 

1- more frequent in dusty or humid conditions

 

Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.

To ensure efficient operation and longer life of the air compressor, a routine maintenance schedule should be prepared and followed. The above routine maintenance schedule is geared to an air compressor in a normal working environment operating on a daily basis. If necessary, the schedule should be modified to suit the conditions under which your air compressor is used. The modifications will depend upon the hours of operation and the working environment. Compressors in an extremely dirty and/or hostile environment will require a greater frequency of all maintenance checks.

NOTE: See "Operation" section for the location of controls.

To Check Safety Valve

Risk of Bursting. If the safety valve does not work properly, over- pressurization may occur, causing air tank rupture or an explosion.

1.Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve

is stuck or does not operate smoothly, it must be replaced with the same type of valve.

To Drain Tank

1.Set the On/Auto/Off lever to "Off" and unplug unit.

2.Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero.

3.Remove the air tool or accessory.

4.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

5.Drain water from air tank by opening drain valve (counter- clockwise) on bottom of tank.

Risk of Bursting. Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

15- ENG

A10819

Image 15
Contents AIR Compressor Table of Contents Specification Chart Safety Guidelines DefinitionsImportant Safety Instructions Always remain in attendance with What Could HappenAttachments & Accessories Personnel can result in serious injury Safety equipment must be properlyElectricity. Like any other electrically Repairs attempted by unqualifiedHazard Warning Risk from Moving Parts Result in serious burns How To Prevent ItEquip area of operation with a fire extinguisher Keep children away from the air compressor at all timesDuty Cycle AccessoriesAccessories GlossaryLocation of the Air Compressor AssemblyInstallation UnpackingVoltage and Circuit Protection Extension CordsRegulator OperationKnow Your Air Compressor Description of OperationHow to Stop Before StartingAir Compressor Pump not shown Before Each Start-Up How to StartTo Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesAir Filter Inspection Replacement Air Compressor Pump Intake and Exhaust ValvesAir Filter Tube Service and AdjustmentsTo Replace or Clean Check Valve Outlet Tube Nut Pressure ReliefTo Replace Regulator Storage Troubleshooting Being used Check wiring connection ENG A10819 Contenido GarantíaGarantía Total DE UN AÑO DEL Compresor DE Aire Lesiones serias Definiciones DE Normas DE SeguridadModelo Nº 919.167320Instrucciones Importantes DE Seguridad Guarde Estas Instrucciones¿Cómo prevenirlo? ¿Qué puede occurrir? ¿Cómo prevenirlo? Advertencia Riesgo de ExplosiónAdvertencia Riesgo de Inhalación ¿Qué puede occurrir? Advertencia Riesgo de Quemaduras ¿Qué puede occurrir? Advertencia Riesgo de Partes Móviles ¿Qué puede occurrir?Advertencia Riesgo de Caída ¿Qué puede occurrir? Conservar Estas Instrucciones Accesorios GlosarioAccesorios Ciclo DE ServicioCómo Preparar LA Unidad Ubicación del compresor de aire EnsambladoInstalación DesempaqueProtección del voltaje y del circuito Cables de extensión eléctricaPara referencias futuras OperaciónConozca su compresor de aire Descripción de operacionesProcedimiento para el asentamiento Cómo utilizar su unidadAntes de poner en marcha Cómo detenerlaCómo poner en marcha Antes de cada puesta en marchaCómo drenar el tanque MantenimientoResponsabilidades del cliente Cómo verificar la válvula de seguridadFiltro de aire Filtro de Aire Inspección y reemplazoDe presión Servicio Y AjustesPara reemplazar o limpiar la válvula de retención Tubo de Tuerca Salida Tubo aliviadorNiple Para reemplazar el reguladorRegulador RápidoAlmacenaje Problema Causa Corrección Guía DE Diagnóstico DE ProblemasSe utiliza un Pintura por rociado. Vea la 49- SP A10819 A10819 50- SP  Product replacement if your covered product cant be fixed Repair Protection AgreementsContratos de Protección para Reparaciones SU-HOGARSM MY-HOMESears Parts and Repair Center Canada