Craftsman 919.16732 Electricity. Like any other electrically, Repairs attempted by unqualified

Page 6

HAZARD

WARNING: Risk of Electrical Shock

What Could Happen

How To Prevent It

Your air compressor is powered by

Never operate the compressor outdoors

electricity. Like any other electrically

when it is raining or in wet conditions.

powered device, If it is not used

Never operate compressor with

properly it may cause electric shock.

protective covers removed or damaged.

 

 

 

Repairs attempted by unqualified

Any electrical wiring or repairs required

personnel can result in serious injury

on this product should be performed by

or death by electrocution.

authorized service center personnel in

 

accordance with national and local

 

electrical codes.

 

 

Electrical Grounding: Failure to provide

Make certain that the electrical circuit

adequate grounding to this product

to which the compressor is connected

could result in serious injury or death

provides proper electrical grounding,

from electrocution.

correct voltage and adequate fuse

See grounding instructions.

protection.

 

 

HAZARD

WARNING: Risk to Breathing

What Could Happen

How To Prevent It

The compressed air directly from your

Air obtained directly from the compressor

compressor is not safe for breathing.

should never be used to supply air for

The air stream may contain carbon

human consumption. In order to use air

monoxide, toxic vapors, or solid

produced by this compressor for

particles from the tank. Breathing these

breathing, suitable filters and in-line

contaminants can cause serious injury

safety equipment must be properly

or death.

installed. In-linefilters and safety

 

equipment used in conjunction with the

 

compressor must be capable of treating

 

air to all applicable local and federal

 

codes prior to human consumption.

 

 

Sprayed materials such as paint, paint

Work in an area with good cross

solvents, paint remover, insecticides,

ventilation. Read and follow the safety

weed killers, may contain harmful

instructions provided on the label or

vapors and poisons.

safety data sheets for the materials

 

you are spraying. Use a NIOSH/MSHA

 

approved respirator designed for use

 

with your specific application.

 

 

A10819

6- ENG

Image 6
Contents AIR Compressor Table of Contents Specification Chart Safety Guidelines Definitions Important Safety Instructions What Could Happen Always remain in attendance withAttachments & Accessories Repairs attempted by unqualified Safety equipment must be properlyElectricity. Like any other electrically Personnel can result in serious injuryResult in serious burns How To Prevent It Hazard Warning Risk from Moving PartsKeep children away from the air compressor at all times Equip area of operation with a fire extinguisherGlossary AccessoriesAccessories Duty CycleUnpacking AssemblyInstallation Location of the Air CompressorExtension Cords Voltage and Circuit ProtectionDescription of Operation OperationKnow Your Air Compressor RegulatorHow to Stop Before StartingAir Compressor Pump not shown How to Start Before Each Start-UpCustomer Responsibilities MaintenanceTo Check Safety Valve To Drain TankAir Filter Inspection Replacement Air Compressor Pump Intake and Exhaust ValvesAir Filter Outlet Tube Nut Pressure Relief Service and AdjustmentsTo Replace or Clean Check Valve TubeTo Replace Regulator Storage Troubleshooting Being used Check wiring connection ENG A10819 Contenido GarantíaGarantía Total DE UN AÑO DEL Compresor DE Aire 919.167320 Definiciones DE Normas DE SeguridadModelo Nº Lesiones seriasInstrucciones Importantes DE Seguridad Guarde Estas Instrucciones¿Cómo prevenirlo? Advertencia Riesgo de Explosión ¿Qué puede occurrir? ¿Cómo prevenirlo?Advertencia Riesgo de Inhalación ¿Qué puede occurrir? Advertencia Riesgo de Quemaduras ¿Qué puede occurrir? Advertencia Riesgo de Partes Móviles ¿Qué puede occurrir?Advertencia Riesgo de Caída ¿Qué puede occurrir? Conservar Estas Instrucciones Ciclo DE Servicio GlosarioAccesorios AccesoriosDesempaque EnsambladoInstalación Cómo Preparar LA Unidad Ubicación del compresor de aireCables de extensión eléctrica Protección del voltaje y del circuitoDescripción de operaciones OperaciónConozca su compresor de aire Para referencias futurasCómo detenerla Cómo utilizar su unidadAntes de poner en marcha Procedimiento para el asentamientoAntes de cada puesta en marcha Cómo poner en marchaCómo verificar la válvula de seguridad MantenimientoResponsabilidades del cliente Cómo drenar el tanqueFiltro de Aire Inspección y reemplazo Filtro de aireTubo de Tuerca Salida Tubo aliviador Servicio Y AjustesPara reemplazar o limpiar la válvula de retención De presiónRápido Para reemplazar el reguladorRegulador NipleAlmacenaje Guía DE Diagnóstico DE Problemas Problema Causa CorrecciónSe utiliza un Pintura por rociado. Vea la 49- SP A10819 A10819 50- SP  Product replacement if your covered product cant be fixed Repair Protection AgreementsContratos de Protección para Reparaciones Canada MY-HOMESears Parts and Repair Center SU-HOGARSM