Craftsman 919.16732 owner manual Check wiring connection

Page 22

PROBLEM

CAUSE

CORRECTION

Regulator will

Damaged regulator.

Replace.

not shut off air

 

 

outlet.

 

 

Motor will not

Motor overload protection

Let motor cool off and

run.

switch has tripped.

overload switch will

 

 

automatically reset.

 

Tank pressure exceeds

Motor will start automatically

 

pressure switch "cut-in"

when tank pressure drops

 

pressure.

below "cut-in" pressure of

 

 

pressure switch.

 

Extension cord is wrong

Check for proper gauge wire

 

length or gauge.

and cord length.

 

Check valve stuck open.

Remove and clean, or

 

 

replace.

 

Loose electrical connections.

Check wiring connection

 

 

inside pressure switch and

 

 

terminal box area.

 

Possible defective motor or

Have checked by a Trained

 

starting capacitor.

Service Technician.

 

Paint spray on internal motor

Have checked by a Trained

 

parts.

Service Technician. Do not

 

 

operate the compressor in

 

 

the paint spray area. See

 

 

flammable vapor warning.

 

Pressure release valve on

Bleed the line by pushing the

 

pressure switch has not

lever on the pressure switch

 

unloaded head pressure.

to the "OFF" position; if the

 

 

valve does not open, replace

 

 

switch.

 

Fuse blown, circuit breaker

1. Check fuse box for blown

 

tripped.

fuse and replace as

 

 

necessary. Reset circuit

 

 

breaker. Do not use a fuse

 

 

or circuit breaker with

 

 

higher rating than that

 

 

specified for your particular

 

 

branch circuit.

 

 

2. Check for proper fuse. You

 

 

should use a time delay

 

 

fuse.

 

 

3. Check for low voltage

 

 

conditions and/or proper

 

 

extension cord.

 

 

4. Disconnect the other

 

 

electrical appliances from

 

 

circuit or operate the

 

 

compressor on its own

 

 

branch circuit.

A10819

22- ENG

Image 22
Contents AIR Compressor Table of Contents Safety Guidelines Definitions Specification ChartImportant Safety Instructions What Could Happen Always remain in attendance withAttachments & Accessories Repairs attempted by unqualified Safety equipment must be properlyElectricity. Like any other electrically Personnel can result in serious injuryResult in serious burns How To Prevent It Hazard Warning Risk from Moving PartsKeep children away from the air compressor at all times Equip area of operation with a fire extinguisherGlossary AccessoriesAccessories Duty CycleUnpacking AssemblyInstallation Location of the Air CompressorExtension Cords Voltage and Circuit ProtectionDescription of Operation OperationKnow Your Air Compressor RegulatorBefore Starting How to StopAir Compressor Pump not shown How to Start Before Each Start-UpCustomer Responsibilities MaintenanceTo Check Safety Valve To Drain TankAir Compressor Pump Intake and Exhaust Valves Air Filter Inspection ReplacementAir Filter Outlet Tube Nut Pressure Relief Service and AdjustmentsTo Replace or Clean Check Valve TubeTo Replace Regulator Storage Troubleshooting Being used Check wiring connection ENG A10819 Garantía ContenidoGarantía Total DE UN AÑO DEL Compresor DE Aire 919.167320 Definiciones DE Normas DE SeguridadModelo Nº Lesiones seriasGuarde Estas Instrucciones Instrucciones Importantes DE Seguridad¿Cómo prevenirlo? Advertencia Riesgo de Explosión ¿Qué puede occurrir? ¿Cómo prevenirlo?Advertencia Riesgo de Inhalación ¿Qué puede occurrir? Advertencia Riesgo de Partes Móviles ¿Qué puede occurrir? Advertencia Riesgo de Quemaduras ¿Qué puede occurrir?Advertencia Riesgo de Caída ¿Qué puede occurrir? Conservar Estas Instrucciones Ciclo DE Servicio GlosarioAccesorios AccesoriosDesempaque EnsambladoInstalación Cómo Preparar LA Unidad Ubicación del compresor de aireCables de extensión eléctrica Protección del voltaje y del circuitoDescripción de operaciones OperaciónConozca su compresor de aire Para referencias futurasCómo detenerla Cómo utilizar su unidadAntes de poner en marcha Procedimiento para el asentamientoAntes de cada puesta en marcha Cómo poner en marchaCómo verificar la válvula de seguridad MantenimientoResponsabilidades del cliente Cómo drenar el tanqueFiltro de Aire Inspección y reemplazo Filtro de aireTubo de Tuerca Salida Tubo aliviador Servicio Y AjustesPara reemplazar o limpiar la válvula de retención De presiónRápido Para reemplazar el reguladorRegulador NipleAlmacenaje Guía DE Diagnóstico DE Problemas Problema Causa CorrecciónSe utiliza un Pintura por rociado. Vea la 49- SP A10819 A10819 50- SP Repair Protection Agreements  Product replacement if your covered product cant be fixedContratos de Protección para Reparaciones Canada MY-HOMESears Parts and Repair Center SU-HOGARSM