Friedrich 9, 000 BTU'S service manual Accessories, Wall Plenum, Drain PAN

Page 53

ACCESSORIES

MODEL

 

DESCRIPTION

PHOTO

 

 

 

 

WALL PLENUM

 

 

 

1

2

 

 

 

VPAWP1-8

 

 

 

 

 

3 8

 

1 8

 

 

 

7 8

5 8

 

VPAWP1-14

 

ARCHITECTURAL LOUVER

 

 

VPAL2

1 16

9 16

 

 

 

 

 

 

 

VPSC2

 

 

 

 

 

 

RT4

DIGITAL REMOTE WALL THERMOSTAT Single stage

thermostat, used on VERT-I-PAK units. Hard wired with single

 

speed fan. Direct replacement for RT2.

 

DIGITAL REMOTE WALL THERMOSTAT Single stage

RT5

thermostat. Features high/low fan speed switch. Thermostat

is hard wired and can be battery powered or unit powered.

 

 

Features backlit display and multiple configured modes.

 

 

 

ACCESS PANEL / RETURN AIR GRILLE – Serves as an access

 

panel to chassis and interior return air grille. A field-supplied

 

(25" x 20") filter is mounted inside the hinged access door.

 

Kit contains hinge bracket for mounting the door with the return

 

air openings high or low on the door for optimal sound attenuation.

VPRG4

For 9,000 / 12,000 / 18,000 Btu models, it is recommended to

install the door with the hinge on the right side and the return air

 

 

openings high on the door. For 24,000 Btu models, it is

 

recommended to install the hinge on the left side with the return

 

air openings low on the door.

 

DIMENSIONS: 58" high x 29" wide.

 

COUTOUT DIMENSIONS: 55 3/4" high x 27" wide.

 

 

VPDP1

DRAIN PAN

24,000 BTU ONLY

51

Image 53
Contents Single Package Vertical Air Conditioning System Technical Support Contact Information Table of Contents Your safety and the safety of others are very important Important Safety InformationRefrigeration System Hazards Property Damage Hazards IntroductionSerial Number Identification Guide Electric Heat Data Chassis SpecificationsVEA Extended Cooling Performance Extended Cooling PerformanceVEA/VHA09-24 VEA Extended Cooling Performance Electric Shock Hazard Electrical RequirementsRT5 Two speed fan RT4 One speed fan Remote Thermostat and Low Voltage Control ConnectionsThermostat Connections Quiet Start/Stop Electronic Control Board FeaturesElectronic Control Configuration Test Mode Electronic control error codes diagnostics and test modeDiagnostics Power On and Off Features on the Electronic Control Cool mode control features for cool with electric heat units Compressor operation depends on t-stat settings VERT-I-PAK Single Packaged Vertical AIR Conditioners Component description / A-Series specificationsExternal Static Pressure Indoor Airflow Data Capacitors Components TestingCapacitor Check with Capacitor Analyzer Capacitor ConnectionsDrain PAN Valve Components TestingHeater Elements and Limit SWITCHES’ Specifications Refrigeration Sequence of Operation Refrigeration AssemblyCUT/SEVER Hazard ServiceEquipment Required Sealed Refrigeration System RepairsEquipment Must be Capable Risk of Electric ShockFreeze Hazard Method Of Charging / RepairsBurn Hazard Overcharged Refrigerant Systems Undercharged Refrigerant SystemsRestricted Refrigerant System Metering Device Hermetic Components CheckCheck Valve Capillary Tube SystemsReversing Valve DESCRIPTION/OPERATION Checking the Reversing Valve Testing the CoilTouch Test in Heating/Cooling Cycle Procedure For Changing Reversing ValveFire Hazard Explosion HazardCompressor Checks Checking Compressor Efficiency Single Phase Resistance TestGround Test High Temperatures Compressor ReplacementRecommended procedure for compressor replacement Rotary Compressor Special Troubleshooting and Service Coils and Base PAN Excessive Weight Hazard Routine MaintenanceBlower Wheel / Housing / Condenser FAN / Shroud AIR FilterSleeve / Drain Routine MaintenanceFront Cover Condensate Disposal System9K BTU, 12K BTU, & 18K BTU Electrical Troubleshooting Chart CoolingCircuit Breakers are Electrical Troubleshooting Chart Cooling 24K BTUHeat Pump Mode Electrical Troubleshooting Chart Heat PumpTroubleshooting Chart Heating Troubleshooting Chart CoolingElectric Heat VEA 09/12/18 with 2.5 KW, 3.4 KW or 5KWVHA 09/12/18 with 2.5 KW, 3.4 KW or 5KW Cool with Electric Heat Heat Pump with Electric Heat Cool with Electric Heat Heat Pump with Electric Heat Outdoor Coil Return Air Indoor Coil Drain PAN AccessoriesWall Plenum Friedrich Air Conditioning Company Technical Support Contact Information Friedrich AIR Conditioning CO