Xantrex Technology 10 owner manual Key Installation Points

Page 19

Installation Precautions

Key Installation Points

Observe proper polarity when connecting batteries. Reverse DC polarity will result in damage to the Freedom 10.

Do not backfeed the AC output of the inverter with incoming AC power. Double check all aspects of your AC wiring for the possibility of backfeeding. A backfeed will cause significant damage to your unit.

Do not connect the AC input to the AC output. In effect, this would be plugging the battery charger into the inverter. This could occur if the Freedom 10 is connected to the entire leg of a circuit breaker panel, then a circuit breaker on that leg is used to feed the battery charger. This will cause the unit to oscillate on and off when the unit is in inverter mode.

Always use properly sized wire and connectors, keeping in mind that considerable amperage flows in the DC circuit. Fusing the positive DC cable is required.

Keep the Freedom 10 out of the elements and out of direct contact with water. Remember that the unit is a piece of electronic equipment and treat it accordingly.

Mount the unit as close to the batteries as possible but not in the presence of flammable fumes or in an enclosed battery compartment.

Do not bolt the unit down until the AC, remote, and ground wiring is completed.

975-0251-01-01

2–3

Image 19
Contents Freedom Inverter/Charger Page Freedom 10 Inverter/Charger Date and Revision Related Information Purpose ScopeAudience Conventions UsedPage Important Safety Instructions Precautions When Working With Batteries Explosive gas precautionsPrecautions for Using Rechargeable Appliances Viii Contents Glossary TroubleshootingSpecifications OperationIntroduction 1Freedom 10 Inverter/Charger IntroductionIntended Use Things You Should KnowCircuit Breaker Protection Electronic Protection Power SharingInverter ldle Circuit Installation Appropriate Applications Installation PrecautionsKey Installation Points Location Recreational Vehicle InstallationNeutral Bonding GroundingWire Color Description AC WiringResidual Current Circuit Breaker Remote Control WiringDC End DC Wiring4Fuse installation Battery Cable Fusing5Ground, AC, and Remote Connection Locations Marine InstallationMarine Installation 6AC Compartment Cover Plate Screws Residual Current Circuit Breaker DC Wiring 8Fuse installation 9Ground, AC, and Remote Connection Locations Residential Solar InstallationResidential Solar Installation 10AC Compartment Cover Plate Screws Residential Solar Installation 11 DC End 12Fuse installation Page Operation Remote Control Panel Freedom 10 Power SwitchModels Power Switch DC Volts Bar Graph 4Freedom Remote Control Dip Switches DIP Switch Status Remote Power Consumption Link 2000 Remote Control PanelBatteries Battery TypesSeries Battery InterconnectionParallel 4Typical Power Consumption Conventional Battery Chargers Battery ChargingFreedom Battery Charger Bulk Charge Equalizing Batteries Charging Over-Discharged Batteries 5Battery Charger Voltage Settings Battery Charger Voltage SettingsTroubleshooting Troubleshooting Guide Using the Remote Control DC Amps LED Bar GraphSpecifications 12 VDC 24 VDC SpecificationsGlossary AWG Glossary of TermsLED Page Warranty Warranty and Return InformationProduct DisclaimerExclusions Return Procedure Return Material Authorization PolicyOut of Warranty Service Purchased From Purchase Date Information About Your SystemPage Xantrex Technology Inc