Operation

Freedom 10 Power Switch

The power switch is located on the front panel of the Freedom 10. This switch controls ON/OFF and RESET for the inverter. Expect a 3-second delay when the power switch is turned ON before the unit is activated.

If installed with the remote control panel, the power switch on the unit itself should be left in the OFF position.

If the unit is connected to external AC power, the power switch may be turned off, but the battery charger will continue to function. The internal transfer switch will continue to be engaged with the switch off and AC power will be available at the output of the unit. If AC power is removed, the unit will not come on as an inverter.

Figure 3-1Freedom 10 Power Switch

Important: The power switch controls the inverter function. Placing the switch in the OFF position disables the inverter and connects mains to the output.

Remote Control Panel

12 V Models

The remote control panel provides LED bar graphs that show system status, battery voltage, and current in both inverter and charge modes. For more information about this remote, refer to its owner’s manual.

Figure 3-2Remote Control Panel For 12 V Models

3–2

975-0251-01-01

Image 40
Contents Freedom Inverter/Charger Page Freedom 10 Inverter/Charger Date and Revision Purpose Scope AudienceConventions Used Related InformationPage Important Safety Instructions Explosive gas precautions Precautions When Working With BatteriesPrecautions for Using Rechargeable Appliances Viii Contents Troubleshooting SpecificationsOperation GlossaryIntroduction Introduction 1Freedom 10 Inverter/ChargerIntended Use Things You Should KnowCircuit Breaker Protection Electronic Protection Power SharingInverter ldle Circuit Installation Installation Precautions Appropriate ApplicationsKey Installation Points Recreational Vehicle Installation LocationGrounding Neutral BondingAC Wiring Wire Color DescriptionRemote Control Wiring Residual Current Circuit BreakerDC Wiring DC EndBattery Cable Fusing 4Fuse installationMarine Installation 5Ground, AC, and Remote Connection LocationsMarine Installation 6AC Compartment Cover Plate Screws Residual Current Circuit Breaker DC Wiring 8Fuse installation Residential Solar Installation 9Ground, AC, and Remote Connection LocationsResidential Solar Installation 10AC Compartment Cover Plate Screws Residential Solar Installation 11 DC End 12Fuse installation Page Operation Remote Control Panel Freedom 10 Power SwitchModels Power Switch DC Volts Bar Graph 4Freedom Remote Control Dip Switches DIP Switch Status Link 2000 Remote Control Panel Remote Power ConsumptionBattery Types BatteriesBattery Interconnection SeriesParallel 4Typical Power Consumption Conventional Battery Chargers Battery ChargingFreedom Battery Charger Bulk Charge Equalizing Batteries Charging Over-Discharged Batteries Battery Charger Voltage Settings 5Battery Charger Voltage SettingsTroubleshooting Using the Remote Control DC Amps LED Bar Graph Troubleshooting GuideSpecifications Specifications 12 VDC 24 VDCGlossary Glossary of Terms AWGLED Page Warranty and Return Information WarrantyProduct DisclaimerExclusions Return Procedure Return Material Authorization PolicyOut of Warranty Service Information About Your System Purchased From Purchase DatePage Xantrex Technology Inc