Studer Innotec XTH 6000-48, XTH 8000-48 Introduction, General information, Operating instructions

Page 3

STUDER Innotec

Xtender

1 Introduction

Congratulations! You are about to install and use a device from the Xtender range. You have chosen a high-tech device that will play a central role in energy saving for your electrical installation. The Xtender has been designed to work as an inverter / charger with advanced functions, which can be used in a completely modular way and guarantee the faultless functioning of your energy system.

When the Xtender is connected to a generator or network, the latter directly supplies the consumers, and the Xtender works like a battery charger and backup device if necessary. The powerful battery charger has an exceptional high efficiency and power factor correction (PFC) close to 1. It guarantees excellent battery charging in all situations. The charge profile is freely configurable according to the type of battery used or the method of usage. The charge voltage is corrected depending on the temperature, thanks to the optional external sensor. The power of the charger is modulated in real time dependent according to the demand of the equipment connected at the Xtender output and the power of the energy source (network or generator). It can even temporarily backup the source if the consumer demand exceeds the source capacity.

The Xtender continuously monitors the source to which it is connected (network or generator) and disconnects itself immediately if the source is missing, disturbed or does not correspond to the quality criteria (voltage, frequency, etc.). It will then function in independent mode, thanks to the integrated inverter. This inverter, which has an extremely robust design, benefits from STUDER Innotec’s many years of experience and expertise in this area. It could supply any type of load without faults, enjoying reserves of additional power that is unmatched on the market. All your equipment will be perfectly provided with energy and protected from power outages in systems where energy supply is unpredictable (unreliable network) or voluntarily limited or interrupted, such as hybrid installations on remote sites or mobile installations.

The parallel and/or three-phase network operation of the Xtender offers modularity and flexibility and enables optimum adaptation of your system to your energy requirements.

The RCC-02/03 control, display and programming centre (optional) enables optimum configuration of the system and guarantees the operator continuous control for all important configurations in the installation.

In order to guarantee perfect commissioning and functioning of your installation, please read this manual carefully. It contains all the necessary information relating to the functioning of the inverters / chargers in the Xtender series. The setting up of such a system requires special expertise and may only be carried out by qualified personnel familiar with the applicable local regulations.

2 General information

2.1 Operating instructions

This manual is an integral part of each inverter/charger from the Xtender series. It covers the following models and accessories:

Xtender: XTH 3000-12 – XTH 5000-24 – XTH 6000-48 – XTH 8000-48

Temperature sensor: BTS-01

For greater clarity, the device is referred to in this manual as Xtender, unit or device, when the description of its functioning applies indiscriminately to different Xtender models.

These operating instructions serve as a guideline for the safe and efficient usage of the Xtender. Anyone who installs or uses an Xtender can rely completely on these operating instructions, and is bound to observe all the safety instructions and indications contained. The installation and commissioning of the Xtender must be entrusted to a qualified professional. The installation and usage must conform to the local safety instructions and applicable standards in the country concerned.

Installation and operating Instructions

Xtender V1.3

Page 3

Image 3
Contents Xtender Table of Contents Introduction General informationOperating instructions Conventions Quality and warrantyExclusion of Liability Storage Assembly and installationInstallation site Handling and movingConnections FasteningDescription Comment PosChoice of system CablingEarthing system Recommendations for dimensioning the system XTH3000-12 XTH5000-24 XTH6000-48 XTH8000-48 Wiring diagramsConnecting the battery Fuse on the battery sideBATTERY-SIDE Connection Connecting the Consumers AT the 230 V AC Output Connecting the battery Powering up the installationCircuit diagram Description and functioningDescription of the main functions Fast voltage loss detection mode fast transfer Temperature is increased or the ventilation Limiting the Input Current by Limiting the Charger Current Input Current Controlled by Input Voltage Auxiliary Contacts Multi-unit configurations RCC-02 RCC-03 AccessoriesDisplay and control parts Indicated alarm CommentControl Main on/off controlCheck the cause of this excess voltage. The equipment will Maintenance of the installation Product recyclingEC declaration of conformity Comments of annexes’ figures Example of parallel connection of 2 or 3 Xtenders Example of installation in a vehicle AC partInstallation example in a boat, with isolation transformer Example of a hybrid installationElem Description Comment Figure elements DC partFigure elements AC part Elements of connexion cabinet a Type plate elements b Control and display parts for the Xtender bStuder Innotec Xtender Table of standard configurations Studer Innotec Xtender Model XTH 3000-12 XTH 5000-24 XTH 6000-48 XTH Technical data