Studer Innotec XTH 8000-48, XTH 6000-48, XTH 5000-24 Conventions, Quality and warranty

Page 4

STUDER Innotec

Xtender

2.2 Conventions

This symbol is used to indicate the presence of a dangerous voltage that is sufficient to constitute a risk of electric shock.

This symbol is used to indicate a risk of material damage.

This symbol is used to indicate information that is important or which serves to optimise your system.

All values mentioned hereafter, followed by a configuration no. indicate that this value may be modified with the help of the RCC-02/03 remote control.

In general, the default values are not mentioned and are replaced by a configuration no. in the following format: {xxxx}. The default values for this configuration are specified in the configuration table, p. 34.

All configuration values modified by the operator or installer must be transferred into the same table. If a parameter not appearing in the list (advanced configurations) has been modified by an authorised person with technical knowledge, they will indicate the number of the modified parameter(s), the specifications of the configuration(s) and the new value set, at the end of the same table.

All figures and letters indicated in brackets refer to items of figures in the separate manual “Appendix to the installation and operating instructions” supplied with the device.

The figures in brackets refer to elements belonging to the Xtender. The uppercase letters in brackets refer to AC cabling elements. The lowercase letters in brackets refer to battery cabling elements.

2.3 Quality and warranty

During the production and assembly of the Xtender, each unit undergoes several checks and tests. These are carried out with strict adherence to the established procedures. Each Xtender has a serial number allowing complete follow-up on the checks, according to the particular data for each device. For this reason it is very important never to remove the type plate (appendix I – fig. 3b) which shows the serial number. The manufacture, assembly and tests for each Xtender are carried out in their entirety by our factory in Sion (CH). The warranty for this equipment depends upon the strict application of the instructions appearing in this manual.

The warranty period for the Xtender is 2 years.

2.3.1EXCLUSION OF WARRANTY

No warranty claims will be accepted for damage resulting from handling, usage or processing that does not explicitly appear in this manual. Cases of damage arising from the following causes are notably excluded from the warranty:

Surge voltage on the battery input (for example, 48 V on the battery input of an XTH 3000- 12)

Incorrect polarity of the battery

The accidental ingress of liquids into the device or oxidation resulting from condensation

Damage resulting from falls or mechanical shocks

Modifications carried out without the explicit authorisation of Studer Innotec

Nuts or screws that have not been tightened sufficiently during the installation or maintenance

Damage due to atmospheric surge voltage (lightning)

Damage due to inappropriate transportation or packaging

Disappearance of original marking elements

Installation and operating Instructions

Xtender V1.3

Page 4

Image 4
Contents Xtender Table of Contents General information IntroductionOperating instructions Quality and warranty ConventionsExclusion of Liability Assembly and installation Installation siteHandling and moving StorageFastening ConnectionsPos Description CommentCabling Choice of systemEarthing system Recommendations for dimensioning the system Wiring diagrams Connecting the batteryFuse on the battery side XTH3000-12 XTH5000-24 XTH6000-48 XTH8000-48BATTERY-SIDE Connection Connecting the Consumers AT the 230 V AC Output Powering up the installation Connecting the batteryDescription and functioning Circuit diagramDescription of the main functions Fast voltage loss detection mode fast transfer Temperature is increased or the ventilation Limiting the Input Current by Limiting the Charger Current Input Current Controlled by Input Voltage Auxiliary Contacts Multi-unit configurations Accessories RCC-02 RCC-03Indicated alarm Comment ControlMain on/off control Display and control partsCheck the cause of this excess voltage. The equipment will Product recycling Maintenance of the installationEC declaration of conformity Comments of annexes’ figures Example of installation in a vehicle AC part Installation example in a boat, with isolation transformerExample of a hybrid installation Example of parallel connection of 2 or 3 XtendersFigure elements DC part Elem Description CommentFigure elements AC part Elements of connexion cabinet a Control and display parts for the Xtender b Type plate elements bStuder Innotec Xtender Table of standard configurations Studer Innotec Xtender Technical data Model XTH 3000-12 XTH 5000-24 XTH 6000-48 XTH