Studer Innotec XTH 8000-48 Technical data, Model XTH 3000-12 XTH 5000-24 XTH 6000-48 XTH

Page 36

STUDER Innotec

Xtender

18 Technical data

Model

XTH 3000-12 XTH 5000-24 XTH 6000-48 XTH 8000-48

Inverter

Rated battery voltage

12 V

 

24 V

48 V

48 V

Input voltage range

9.5 - 17 V

 

19 - 34 V

38 - 68 V

39 - 68 V

Continuous power @ 25 °C

2500 VA

 

4500 VA

5000 VA

7,000 VA

Smart boost power

3000VA

 

5000 VA

6000 VA

8000 VA

30 minute load @ 25 °C

3000 VA

 

5000 VA

6000 VA

8000 VA

5 second load @ 25 °C

 

 

3 x Pcont

 

Maximum load

 

 

Up to short-circuit

 

Maximum asymmetrical load

 

 

Up to Pnom

 

Load detection (standby)

 

 

2 to 25 W

 

Admissible cos phi

 

 

0.1 – 1

 

Maximum efficiency

93%

 

94%

96%

96%

Open-circuit power OFF/standby/ON

1.3W/2.2W/14W

1.8W/2.5W/18W

2.2W/3W/22W

2.2W/3.8W/26 W

Output voltage

 

Sine wave 230 Vac (+/-2%) / 180-245 Vac

Output frequency

50 Hz adjustable 45-65 Hz +/- 0.05% (quartz-controlled)

Harmonic distortion

 

<2%

 

Overcharge and short-circuit

Automatic disconnection then 2 startup attempts

Overheating protection

Alarm prior to disconnection and automatic restart

Battery charger

 

 

 

 

 

6-phase battery charger

Programmable I-U-Uo-equalisation-Uo(low)-U(periodic)

Adjustable charge current

0 - 160 A

 

0 - 140 A

0 - 100 A

0 - 120 A

Input current sharing system

 

 

1 - 50 A

 

Maximum input voltage

 

 

265 Vac

 

AC input voltage range

Level of detection adjustable from 150 to 230 Vac

Admissible input frequency

 

 

45 - 65 Hz

 

(PFC)

 

 

EN 61000-3-2

 

Battery control (factory value / adjustable range with RCC-02)

End of absorption

by duration: 2h / 0.25 - 18 h or by current <10A / 2 - 50 A

Absorption voltage

14.4V / 9.5-18

V

28.8V / 19-36 V

 

57.6V / 38 - 72 V

Periodic absorption voltage

- / 9.5 - 18 V

 

- / 19 - 36 V

 

- / 38 - 72 V

Floating voltage

13.6V / 9.5-18

V

27.2V / 19-36 V

 

54.4V / 38 - 72 V

Reduced maintenance voltage

- / 9.5 - 18 V

 

- / 19 - 36 V

 

-- / 38 - 72 V

Equalisation

By number of cycles ( - / - 100) or at fixed intervals ( - / 52 weeks)

End of equalisation

By duration 2h / 0.25 – 10h or by current - / 5 – 50 A

Equalisation voltage

- / 9.5 - 18 V

 

- / 19-36 V

 

- / 38 - 72 V

Low voltage disconnection

10.8V / 9.5-18

V

21.6V /19-36 V

 

43.2V / 38 - 72 V

Reduced floating duration

 

 

- / 0 - 32 days

 

Periodical absorption

 

 

- / 0 - 10 hours

 

Temperature compensation

 

-5 / 0 to-8 mV/°C/cell (optional BTC-01)

 

General data

 

 

 

 

 

 

 

 

Auxiliary contacts

2 independent contacts 16 A - 250 Vac (potential-free 3 points)

Maximum transfer relay current

 

 

50 A

 

 

 

Maximum transfer time

 

 

0-15 ms

 

 

 

Weight

34 kg

 

40 kg

 

 

42 kg

 

46 kg

Dimensions: H x W x D [mm]

 

 

230x300x500

 

Protection degree

 

 

IP20

 

 

 

Conformity

EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 61000-3-2,

 

 

 

Dir. 89/336/EEC, LVD 73/23/EEC

 

Operating temperature range

 

 

-20 to 55 °C

 

Ventilation

 

 

Forced from 45 °C

 

Noise level

<40 dB / <50 dB (without / with ventilation)

 

Warranty

 

 

2 years

 

 

 

Options

 

 

 

 

 

 

 

 

Battery temperature sensor:

BTS-01

 

 

 

 

 

 

 

Remote control and programming centre for wall mounting: RCC-02

 

 

 

Remote control and programming centre for panel mounting: RCC-03

 

 

 

Installation and operating Instructions

Xtender V1.3

Page 36

Image 36
Contents Xtender Table of Contents Introduction General informationOperating instructions Quality and warranty ConventionsExclusion of Liability Assembly and installation Installation siteHandling and moving StorageFastening ConnectionsPos Description CommentCabling Choice of systemEarthing system Recommendations for dimensioning the system Wiring diagrams Connecting the batteryFuse on the battery side XTH3000-12 XTH5000-24 XTH6000-48 XTH8000-48BATTERY-SIDE Connection Connecting the Consumers AT the 230 V AC Output Powering up the installation Connecting the batteryCircuit diagram Description and functioningDescription of the main functions Fast voltage loss detection mode fast transfer Temperature is increased or the ventilation Limiting the Input Current by Limiting the Charger Current Input Current Controlled by Input Voltage Auxiliary Contacts Multi-unit configurations Accessories RCC-02 RCC-03Indicated alarm Comment ControlMain on/off control Display and control partsCheck the cause of this excess voltage. The equipment will Maintenance of the installation Product recyclingEC declaration of conformity Comments of annexes’ figures Example of installation in a vehicle AC part Installation example in a boat, with isolation transformerExample of a hybrid installation Example of parallel connection of 2 or 3 XtendersFigure elements DC part Elem Description CommentFigure elements AC part Elements of connexion cabinet a Control and display parts for the Xtender b Type plate elements bStuder Innotec Xtender Table of standard configurations Studer Innotec Xtender Technical data Model XTH 3000-12 XTH 5000-24 XTH 6000-48 XTH