SM 1619X04086
Extension Cords
If an extension cord is necessary, a cord with adequate size conductors that is capable
of carrying the current necessary for your tool must be used. This will prevent excessive voltage drop, loss of power or overheating. Grounded tools must use 3- wire extension cords that have
NOTE: The smaller the gauge number, the heav ier the cord.
RECOMMENDED SIZES OF ExTENSION CORDS 120 VOLT ALTERNATING CURRENT TOOLS
Tool’s | Cord Size in A.W.G. | Wire Sizes in mm2 | |||||||
Ampere |
|
|
|
|
|
|
|
| |
Cord Length in Feet | Cord Length in Meters | ||||||||
Rating | |||||||||
25 | 50 | 100 | 150 | 15 | 30 | 60 | 120 | ||
| |||||||||
|
|
|
|
|
|
|
| ||
18 | 16 | 16 | 14 | 0.75 | 0.75 | 1.5 | 2.5 | ||
18 | 16 | 14 | 12 | 0.75 | 1.0 | 2.5 | 4.0 | ||
18 | 16 | 14 | 12 | 0.75 | 1.0 | 2.5 | 4.0 | ||
16 | 16 | 14 | 12 | 1.0 | 2.5 | 4.0 | — | ||
14 | 12 | — | — | — | — | — | — | ||
|
|
|
|
|
|
|
|
|
|
| Accessories |
* | (* = standard equipment) | |
** Carrying Case | (** = optional accessories) |
Trouble Shooting
!WARNING
PROBLEM
Read instruction manual first! Remove battery pack from the tool before making adjustments or assembling accessories.
TROUBLE: TOOL WILL NOT START
1.Battery pack not charged.
2.Battery pack not installed properly.
3.Battery pack temperature is too hot or cold for operation.
4.Burned out switch.
REMEDY 1. If equipped, check battery charge condition lights for charge status. Charge battery if needed.
2.Confirm battery is locked and secured to the tool.
3.Let battery sit a few minutes or until it reaches normal operating temperature.
4.Have switch replaced by an Authorized Skil Service Center or Service Station.
TROUBLE: BATTERY PACK WILL NOT CHARGE
PROBLEM 1. Charger not plugged into outlet.
2. Battery pack not completely inserted into charger.
REMEDY 1. Confirm charger is plugged into outlet.
2. Confirm battery pack is inserted into charger completely.