DeWalt D2002M Operating Procedures Start-up Fig, Shut-down Fig, Maintenance Chart

Page 12

English

Operating Procedures

WARNING: Do not operate this unit until you read and understand this instruction manual for safety, operation and maintenance instructions.

Start-up (Fig. 1)

1.Follow Pre-Start Checklist under Preparation for Use.

2.Move the On/Off switch to the ON position and allow tank pres- sure to build. Motor will stop when tank pressure reaches cutout pressure.

CAUTION: Risk of unsafe operation. Compressed air from the unit may contain wa­ter condensation. Do not spray un­filtered­ air at an item that could be damaged by moisture. Some air oper­ated­ tools or devic­es­ may require filtered air. Read the in­structions­ for

the air tool or device.

3.Adjust regulator (D) to desired setting. See Regulator under Features.

Shut-down (Fig. 1)

1.Move On/Off switch (A) is in the OFF position. NOTE: If finished using compressor, follow Steps 2–6.

NOTE: When the unit has been turned off, it is normal to hear a short hiss of air being released.

2.Turn regulator knob (D) counterclockwise until fully closed. Ensure regulated pressure gauge reads 0 psi.

3.Remove hose and accessory.

NOTE: Always turn off and unplug unit when not in use.

Warning: Risk of unsafe operation. Firmly grasp air hose in hand when installing or disconnecting to prevent hose whip.

4.Drain the air tank, see Draining Air Tank under Maintenance. Ensure air tank pressure gauge reads 0 psi.

Warning: Risk of bursting. Drain air tank daily. Water will con- dense in air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

5.Allow the compressor to cool down.

6.Wipe air compressor clean and store in a safe, non-freezing area.

Maintenance

The following procedures must be followed when maintenance or service is performed on the air compressor.

1.Ensure On/Off switch is in the OFF position.

2.Remove air compressor plug from outlet.

3.Drain air tank.

4.Allow air compressor to cool down before starting service. NOTE: All compressed air systems contain maintenance parts (e.g., oil, filters, separators) that are periodically replaced. These used parts may contain substances that are regulated and must be disposed of in accordance with local, state, and federal laws and regulations. NOTE: Take note of the positions and locations of parts during disassembly to make reassembly easier.

NOTE: Any service operations not included in this section should be performed by a DeWALT factory service center or a DeWALT authorized service center.

Maintenance Chart

Procedure

Before Each

Daily or after

See tank

 

Use

each use

warning label

Check safety valve

X

 

 

Drain air tank

 

X

 

 

 

 

 

Remove tank from

 

 

X1

service

 

 

 

1- For more information, call 1-800-4-DeWALT (1-800-433-9258)

12

Image 12 DeWalt D2002M instruction manual Operating Procedures Start-up Fig, Shut-down Fig, Maintenance Chart
Contents Manual DE Instruções Pump/Motor Specifications SpecificationsD2002M Air Compressor ModelDefinitions Safety Guidelines Important Safety InstructionsWhat can happen How to prevent it Or serious injuryPower sanding, sawing Safety data sheets forAlways use certified safety Exposure to chemicalsAttachments & accessories What can happenElectrical Grounding See GroundingInstructions under Keep children­ away from the air compressor at all times Features For Future USEInstallation AssemblyGrounding Instructions Voltage and Circuit ProtectionExtension Cords CompatibilityPreparation For Use Pre-Start Checklist Fig LocationMoving Operating Procedures Start-up Fig MaintenanceMaintenance Chart Shut-down FigChecking Safety Valve AccessoriesTo Drain Tank RepairsGlossary Troubleshooting Guide Troubleshooting CodesProblem Code Possible SolutionUnder Features if pressure drop is excessive While accessory is being usedSee Motor Overload under Features UsedExtension Cords under Installation Compresor de aire D2002M Especificaciones de la BombaEl Motor EspecificacionesDefiniciones Normas de seguridad Guarde estas instruccionesInstrucciones de seguridad importantes Peligro Riesgo de explosión o incendioPeligro Riesgo Respiratorio asfixia Advertencia Riesgo de explosión Elementos y accesoriosAdvertencia riesgo de descarga eléctrica Advertencia Riesgo de objetos despedidos Advertencia Riesgo DE superficies calientesAdvertencia riesgo por piezas móviles Advertencia Riesgo de operación inseguraCaracterísticas Conserve Estas Instrucciones Para Futuras ConsultasAtención riesgo por ruidos Instalación EnsamblajeInstrucciones de conexión a tierra Cables prolongadoresVoltaje y protección del circuito 18 AWGCompatibilidad LugarTrasladar LA Unidad Procedimientos operativos Puesta en marcha FigApagado Fig Mantenimiento Tabla de mantenimientoControlar la válvula de seguridad Cómo drenar el tanque FigAccesorios ReparacionesQUERETARO, QRO Guía de detección de problemas Códigos de detección de problemasSolución Posible Si la válvula aún pierde, debe ser reemplazada AccesorioDe derivación en particular Verifique si el fusible es correcto. Utilice solamente unFusible de acción retardada El adecuadoInterruptor de presión Interruptor de presiónCompressor de ar D2002M Especificações da bomba e do motorEspecificações Pressão DE Arranque AproximadaDefinições Diretrizes de Segurança Instruções de segurança importantesGuarde Estas Instruções Perigo Risco de explosão ou incêndioRespiratório Asfixia Atenção Risco de explosão AcessóriosAtenção Risco de choque elétrico Ligação à terra a ligaçãoTocar qualquer peça de Nunca toque nenhumaProvocar queimaduras GravesAtenção Risco de peças móveis Atenção Risco de operação inseguraNunca anule as características de segurança deste produto Para USO Futuro Atenção Risco de quedaCuidado Risco de ruídos Interruptor Liga I/Desliga OVálvula de segurança Válvula de controleMedidor de pressão manômetro do tanque Regulador Conjunto de conectores rápidos universaisInstalação MontagemComo fazer a ligação à terra Fios de extensãoCompatibilidade LocalizaçãoConsiderações sobre o ruído Alimentação elétricaProcedimentos de operação Como ligar o aparelho FigMover O Compressor Como desligar o aparelho Fig ManutençãoTabela de manutenção Como verificar a válvula de segurançaComo drenar o tanque de ar AcessóriosConsertos GlossárioGuia de Resolução de Problemas Códigos de Identificação de ProblemasCódigo Possível causa Possível SoluçãoEnquanto o acessório estiver sendo usado Maior para operar o acessórioConsulte Proteção contra sobrecarga do motor na seção Automático foi ativado. Não use um fusível ou um Disjuntor automático de valor maior que o especificadoPara seu circuito de derivação Verifique se o fusível é correto. Utilize somente umPage EWALT Industrial Tool Co., 701 Joppa Road, Baltimore, MD FEB10 Part No. N071878 D2002M Copyright 2009, 2010 D eWALT