Code | possible cause | POSSIBLE SOLUTION | |
|
|
| |
15 | Extension cord is wrong length or gauge | Check for proper gauge wire and cord length. See | |
|
| Extension Cords under Installation. | |
|
|
| |
16 | Loose electrical connections | Contact a DeWALT factory service center or a DeWALT | |
|
| authorized service center. | |
|
|
| |
17 | Possible defective motor. | Contact a DeWALT factory service center or a DeWALT | |
|
| authorized service center. | |
|
|
|
|
18 | Fuse blown, circuit breaker tripped | 1. | Check fuse box for blown fuse and replace as necessary. |
|
|
| Reset circuit breaker. Do not use a fuse or circuit |
|
|
| breaker with higher rating than that specified for your |
|
|
| particular branch circuit. |
|
| 2. | Check for proper fuse. Use only a time delay fuse. |
|
| 3. | Check for low voltage conditions and/or proper extension |
|
|
| cord. |
|
| 4. | Disconnect the other electrical appliances from circuit or |
|
|
| operate the compressor on its own branch circuit. |
|
|
| |
19 | Tank pressure exceeds pressure switch | Motor will start automatically when tank pressure drops | |
|
| below | |
|
|
|
|
English