USING A DISC GRINDER

Be certain that the wheel guard and auxiliary handle are installed.

Firmly grip the auxiliary handle and motor housing (Fig. 8). Lift up the rear of the motor housing so that only the front section of the grinding wheel contacts the work. Use light pressure. Always lift the grinder off the work before starting or stopping the motor. The arrow on the front gear housing indicates the direction in which the grinding wheel rotates.

Fig. 8

MAINTENANCE

KEEP TOOL CLEAN

Periodically blow out all air passages with dry compressed air. All plastic parts should be cleaned with a soft damp cloth. NEVER use solvents to clean plastic parts. They could possibly dissolve or otherwise damage the material.

Wear safety glasses while using compressed air.

FAILURE TO START

Should your tool fail to start, check to make sure the prongs on the cord plug are making good contact in the outlet. Also, check for blown fuses or open circuit breakers in the line.

LUBRICATION

This tool has been lubricated with a sufficient amount of high grade lubricant for the life of the unit under normal operating conditions. No further lubrication is necessary.

BRUSH INSPECTION AND LUBRICATION

For your continued safety and electrical protection, brush inspection and replacement on this tool should ONLY be performed by an AUTHORIZED PORTER-CABLE SERVICE STATION or a PORTER-CABLE·DELTA FACTORY SERVICE CENTER.

At approximately 100 hours of use, take or send your tool to your nearest authorized Porter-Cable Service Station to be thoroughly cleaned and inspected. Have worn parts replaced and lubricate with fresh lubricant. Have new brushes installed, and test the tool for performance.

Any loss of power before the above maintenance check may indicate the need for immediate servicing of your tool. DO NOT CONTINUE TO OPERATE TOOL UNDER THIS CONDITION. If proper operating voltage is present, return your tool to the service station for immediate service.

10

Image 10
Contents Instruction Manual Double Insulated Angle Grinder Electrical Safety Safety Guidelines DefinitionsGeneral Safety Rules Work AreaPersonal Safety Tools USE and CareSpecific Rules and Symbols ServiceAdditional Safety Rules for Paint Removal LEAD-BASED Paint should only be Removed by a ProfessionalSymbol Definition Replacement PartsMotor Foreword Extension Cord Selection Functional Description To Start and Stop the ToolTo Install Auxiliary Handle AssemblyTo Install Wheel Guard To Install Grinding Wheel Maintenance OperationAccessories Service and RepairsPORTER-CABLE Limited ONE Year Warranty Manual de Instrucciones Guarde Estas Instrucciones EL Área DE Trabajo Pautas DE SEGURIDAD/DEFINICIONESNormas DE Seguridad Generales LA Seguridad EléctricaLA Seguridad Personal EL USO Y LA Protección DE LA HerramientaNormas DE Seguridad Específicas ServicioSímbolo Definición Refacciones Motor Descripcion DE FuncionesPrólogo Instalación DEL Mango Auxiliar MontajePara Poner LA Máquina EN Marcha Y Pararla Para Instalar EL Protector DE DiscoPara Instalar EL Disco DE Esmeril Desconecte LA Herramienta DE LA Fuente DE PotenciaFuncionamiento Para Usar LA EsmeriladoraFalla DE Ponerse EN Marcha MantenimientoMantenga LAS Herramientas Limpias LubricaciónAccessorios Póliza DE Garantía Limitada DE 1 AÑO DE PORTER-CABLEPage ’utilisation Machine à Disque Émerisé Doublement Isolé Sécurité Électrique Mesures DE Sécurité DéfinitionsRègles DE Sécurité Générales Conservez CES InstructionsSécurité DES Personnes Utilisation ET Entretien DES OutilsConsignes DE Sécurité ET Symboles Spécifiques RéparationSymbole Définition Pièces DE RechangeSélection DU Cordon DE Rallonge Description FonctionnelleMoteur AVANT-PROPOSPour Installer LE Capot COUVRE-MEULE Pour Installer LA Poignée AuxiliairePour Faire Démarrer ET Pour Arrêter L’OUTIL Pour Installer LA Meule Utilisation Utilisation D’UNE L’OUTIL À Disque ÉmeriséImpossibilité DE Mettre L’OUTIL EN Marche EntretienGardez L’OUTIL Propre Inspection DES Balais ET GraissageAccessoires Garantie Limitée D’UN AN Offerte PAR PORTER-CABLECanadian PORTER-CABLE Delta Service Centers