Bryant manual Dimensional DRAWING, Base Unit Ð 619E009,012 FAN Coil Units, 619E 009

Page 13

DIMENSIONAL DRAWING, BASE UNIT Ð 619E009,012 FAN COIL UNITS

UNIT

WEIGHT

A

 

B

 

 

C

619E

 

 

Lb

Kg

in.

mm

in.

mm

in.

 

mm

 

 

009

 

18.7

8.5

33.46

850

11.02

280

6.29

 

160

012

 

24.2

11.0

36.61

930

11.81

300

7.28

 

185

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1. Dimensions are in inches. Dimensions in [ ] are in millimeters.

2. Direction of air¯ow.

3.Refrigerant, drain and power connections may be made rear, left side or right side.

4.Refrigerant is metered by capillary tubes in the outdoor unit. Insulate both refrig- erant lines.

5.Clearances of 31¤2 on top and to the left of the fan coil unit are absolute minimums. Clearances of 10 are recommended.

13

Image 13
Contents Air Conditioning Standard System Features538A 538S 048 Shown DescriptionContents FIELD-INSTALLED Accessory Description and Usage619B,D Standard Features and FIELD-INSTALLED AccessoriesModel Description Hspf System CapacitiesSeer Unit Specifications Ð 538A and 538C Condensing UnitsUnit 538D Specifications Ð 538D Heat Pump UnitsSpecifications Ð 619E FAN Coil Units Specifications Ð 538S Condensing UnitsUnit 538S Unit 619E538 009 55.0 25.0 012 62.0 28.1 60.7 27.5 66.5 30.2 Unit WeightUnit Minimum Mounting PAD DimensionsUnit Operating Unit Operating Weight Ft-in 024 Dimensional DRAWING, Base Unit Ð 538S Condensing Units048 538S Ft-in619E 009 Dimensional DRAWING, Base Unit Ð 619E009,012 FAN Coil Units619E Dimensional DRAWING, Base Unit Ð 619E018,024 FAN Coil UnitsHeat Pump Units Electrical Data Condensing UnitsMULTI-SPLIT Condensing Units FAN Coil Units Electrical DataIndoor Operating Voltage FAN UnitCooling-Only System Shown Cooling Only System Shown Outdoor Units Application DataCondition Condition ALL UnitsMaximum Line Lengths Application DataMaximum Lift Ð FAN Coil Unit Equivalent Below Above CondensingChattleff Common Piston Sizes Fitting Loss in Equivalent FT for ElbowsCooling only System Piston Guide and Refrigerant Charges Heat Pump System Piston Guide and Refrigerant ChargesHorizontal Conguration Change in Indoor Unit Piston Size For ElevationOutdoor Unit Above Indoor Unit Indoor Unit Above Outdoor UnitCondensing Unit Sound Ratings AIR Throw DataFAN Coil High Speed Approximate Unit FAN SpeedCompressor Relay ChartTemperatureResistance 500 11,400 32,500 Typical Wiring Schematic Ð 538A018,024 COOLING-ONLY SystemCompressor K13 Thermistor EquivalenceOutdoor Fan K2 Compressor K1 Temperature Resistance 500 11,400 32,500 Typical Wiring Schematic Ð 538D018,024 Heat Pump SystemOperating Sequence Operating Sequence Electronic Control Defrost Regions Map Outdoor unit. Sensible heat capacity shall not be less than Bryant Day & Night Payne