Bryant 619E manual Specifications Ð 538D Heat Pump Units, Unit 538D

Page 7

SPECIFICATIONS Ð 538D HEAT PUMP UNITS

UNIT 538D

 

 

009

 

012

018

024

 

 

 

 

 

 

 

 

NOMINAL CAPACITY (Tons)

3¤4

 

1

11¤2

2

OPERATING WEIGHT (lb)

60.7

 

66.6

154

167

REFRIGERANT TYPE

 

 

 

R-22

 

Control (Cooling)

Fixed Ori®ce at Outdoor Unit

AccuRater Piston at Fan Coil Unit

Control (Heating)

Fixed Ori®ce at Outdoor Unit

AccuRater Piston at Outdoor Unit

Factory Charge (lb)*

1.5

 

2.0

5.0

5.1

COMPRESSOR TYPE

Carlyle Rotary

Tecumseh Reciprocating

Model

EBA095111H

 

EBB130111H

AW5519G

AW5524G

OUTDOOR FAN

Propeller Type

Propeller, Direct Drive

Rpm (Cooling and Heating)

1050

 

1050

850

850

Nominal Air Cfm (High Speed)

Ð

 

Ð

1720

1720

OUTDOOR COIL

 

 

Copper Tube, Aluminum Fin

 

Face Area (sq ft)...No. of Rows

3.5...1

 

3.5...2

6.1...1.5

6.1...2

Fins/in.

18

 

18

15

15

CONTROLS

 

 

 

 

 

High-Pressure (psig)

 

 

 

 

 

Cutout

Ð

 

Ð

320 ± 20

Cut-in

Ð

 

Ð

426 ±

7

Liquid Line Low-Pressure (psig)

 

 

 

 

 

Cutout

Ð

 

Ð

7 ±

3

Cut-in

Ð

 

Ð

22 ±

5

Fusible Plug

210 F

 

210 F

210 F

Defrost Method²

Time and Temperature Defrost

Time and Temperature Defrost

Accumulator

Yes

 

Yes

Yes

Control Voltage**

115

 

230

24

REFRIGERANT LINES

 

 

 

 

 

Connection Type

 

Flare

SweatÐSuction; FlareÐLiquid

Mixed Phase Line OD (in.)

1¤4

 

1¤4

3¤8

3¤8

Suction Line OD (in.)

1¤2

 

1¤2

5¤8

5¤8

Maximum Length (ft)

35

 

35

200

200

Maximum Lift (Fan Coil Above Outdoor) (ft)

16

 

16

65

65

Maximum Lift (Fan Coil Below Outdoor) (ft)

30

 

30

150

150

EXTERNAL FINISH

 

Grey

Alpine Mist (Beige)

 

 

 

 

 

 

 

 

*Units are shipped with charge listed (smallest applicable system charge). Refer to Piston Guide tables on page 21 for proper charge for your application.

²Demand defrost.

**A 24-v transformer is provided in the 018, 024 fan coil unit.

7

Image 7
Contents Description Standard System FeaturesAir Conditioning 538A 538S 048 ShownContents FIELD-INSTALLED Accessory Description and Usage619B,D Standard Features and FIELD-INSTALLED AccessoriesModel Description Hspf System CapacitiesSeer Unit Specifications Ð 538A and 538C Condensing UnitsUnit 538D Specifications Ð 538D Heat Pump UnitsUnit 619E Specifications Ð 538S Condensing UnitsSpecifications Ð 619E FAN Coil Units Unit 538S538 009 55.0 25.0 012 62.0 28.1 60.7 27.5 66.5 30.2 Unit WeightUnit Minimum Mounting PAD DimensionsUnit Operating Unit Operating Weight 538S Ft-in Dimensional DRAWING, Base Unit Ð 538S Condensing UnitsFt-in 024 048619E 009 Dimensional DRAWING, Base Unit Ð 619E009,012 FAN Coil Units619E Dimensional DRAWING, Base Unit Ð 619E018,024 FAN Coil UnitsHeat Pump Units Electrical Data Condensing UnitsMULTI-SPLIT Condensing Units Operating Voltage FAN Unit Electrical DataFAN Coil Units IndoorCooling-Only System Shown Cooling Only System Shown Condition ALL Units Application DataOutdoor Units ConditionFAN Coil Unit Equivalent Below Above Condensing Application DataMaximum Line Lengths Maximum Lift ÐHeat Pump System Piston Guide and Refrigerant Charges Fitting Loss in Equivalent FT for ElbowsChattleff Common Piston Sizes Cooling only System Piston Guide and Refrigerant ChargesIndoor Unit Above Outdoor Unit Change in Indoor Unit Piston Size For ElevationHorizontal Conguration Outdoor Unit Above Indoor UnitUnit FAN Speed AIR Throw DataCondensing Unit Sound Ratings FAN Coil High Speed ApproximateCompressor Relay ChartThermistor Equivalence Typical Wiring Schematic Ð 538A018,024 COOLING-ONLY SystemTemperatureResistance 500 11,400 32,500 Compressor K13Outdoor Fan K2 Compressor K1 Temperature Resistance 500 11,400 32,500 Typical Wiring Schematic Ð 538D018,024 Heat Pump SystemOperating Sequence Operating Sequence Electronic Control Defrost Regions Map Outdoor unit. Sensible heat capacity shall not be less than Bryant Day & Night Payne