Bryant 619E manual Electrical Data, FAN Coil Units, Indoor, Operating Voltage FAN Unit

Page 16

ELECTRICAL DATA (cont)

FAN COIL UNITS

INDOOR

V (Single-

OPERATING VOLTAGE*

FAN

UNIT

 

 

 

619E

 

 

Ph, 60 Hz)

Minimum

Maximum

FLA

 

 

 

 

 

 

 

009²

 

115

104

127

Ð

012²

 

208/230

187

253

Ð

009**

 

115

104

127

Ð

012**

 

208/230

187

253

Ð

018²

 

 

 

 

 

024²

 

208/230

187

253

0.53

018**

 

 

 

 

 

 

024**

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

FLA

Ð Full Load Amps

HACR Ð Heating, Air Conditioning, Refrigeration

LRA

Ð Locked Rotor Amps

MCA

Ð Minimum Circuit Amps per NEC Section 430-24

NEC

Ð National Electrical Code

RLA

Ð Rated Load Amps (Compressor)

*Permissible limits of the voltage range at which unit will operate satisfactorily.

²Cooling only fan coil unit. **Heat pump fan coil unit.

NOTES:

1.The 018, 024, 048 outdoor units contain a 24-v transformer; addi- tional transformers are not required. The 009, 012 outdoor units use 230-v (high voltage) controls.

2.All motors and compressors contain internal overload protection.

3.In compliance with NEC requirements for multimotor and combina- tion load equipment (refer to NEC Articles 430 and 440), the over- current protective device for the unit shall be fuse or HACR breaker.

4.Motor RLA values are established in accordance with UL (Underwrit- ers' Laboratories) Standard 1995.

16

Image 16
Contents Standard System Features Air Conditioning538A 538S 048 Shown DescriptionFIELD-INSTALLED Accessory Description and Usage ContentsStandard Features and FIELD-INSTALLED Accessories 619B,DModel Description Hspf System CapacitiesSeer Specifications Ð 538A and 538C Condensing Units UnitSpecifications Ð 538D Heat Pump Units Unit 538DSpecifications Ð 538S Condensing Units Specifications Ð 619E FAN Coil UnitsUnit 538S Unit 619EUnit Weight 538 009 55.0 25.0 012 62.0 28.1 60.7 27.5 66.5 30.2Unit Minimum Mounting PAD DimensionsUnit Operating Unit Operating Weight Dimensional DRAWING, Base Unit Ð 538S Condensing Units Ft-in 024048 538S Ft-inDimensional DRAWING, Base Unit Ð 619E009,012 FAN Coil Units 619E 009Dimensional DRAWING, Base Unit Ð 619E018,024 FAN Coil Units 619EHeat Pump Units Electrical Data Condensing UnitsMULTI-SPLIT Condensing Units Electrical Data FAN Coil UnitsIndoor Operating Voltage FAN UnitCooling-Only System Shown Cooling Only System Shown Application Data Outdoor UnitsCondition Condition ALL UnitsApplication Data Maximum Line LengthsMaximum Lift Ð FAN Coil Unit Equivalent Below Above CondensingFitting Loss in Equivalent FT for Elbows Chattleff Common Piston SizesCooling only System Piston Guide and Refrigerant Charges Heat Pump System Piston Guide and Refrigerant ChargesChange in Indoor Unit Piston Size For Elevation Horizontal CongurationOutdoor Unit Above Indoor Unit Indoor Unit Above Outdoor UnitAIR Throw Data Condensing Unit Sound RatingsFAN Coil High Speed Approximate Unit FAN SpeedRelay Chart CompressorTypical Wiring Schematic Ð 538A018,024 COOLING-ONLY System TemperatureResistance 500 11,400 32,500Compressor K13 Thermistor EquivalenceOutdoor Fan K2 Compressor K1 Typical Wiring Schematic Ð 538D018,024 Heat Pump System Temperature Resistance 500 11,400 32,500Operating Sequence Operating Sequence Electronic Control Defrost Regions Map Outdoor unit. Sensible heat capacity shall not be less than Bryant Day & Night Payne