STANDARD FEATURES AND FIELD-INSTALLED ACCESSORIES

STANDARD FEATURE/FIELD-INSTALLED

HIGH WALL

SYSTEMS

ACCESSORY

(619B,D)

 

Internal Condensate Pump

A

Mounting Brackets

S

Microprocessor Controls

S

Cleanable Filters

S

3-Speed Indoor-Fan Motor

S

Automatic Indoor-Fan Speed Control

S

Extensive Diagnostics

S

Wireless Remote Controllers

S

Fully Insulated Indoor Unit Cabinet

S

Automatic Air Sweep

S

Auto. Restart Function

S

24-Hour Automatic Start/Stop Timer

S

Refrigerant Line Turn Elbow*

S

High- and Low-Voltage Terminal Blocks (Indoor)

S

AccuRater Refrigerant Metering Device

Manual Defrost**

S

Demand Defrost**

S

Warm Start (in heating)**

S

Heating Operation to −20 F**

S

Auto. Changeover from Cooling to Heating**

S

Evaporator Coil Freeze Protection

S

Outdoor Low-Voltage Terminal Block

S

Accumulator

S

Crankcase Heater (Reciprocating Compressor Units)

S

Crankcase Heater (Scroll Compressor Units)

A

High-Pressure Switch*

S

Low-Pressure Switch*

S

5-Year Compressor Warranty

S

Compressor Start Assistance (non-scroll units)

S

Cycle-LOC™ Device*

S

Suction and Discharge Service Taps²²

S

Totally Enclosed Fan Motor

S

Acoustically-Lined Compressor Compartment

S

Winter Start Control*

A

Low Ambient Temperature Controls (down to −20 F)²

A

Time Guard Cycle Protector*

S

Liquid Solenoid Valve*

A

Condensing Unit Wall Mount Kit

A

 

 

LEGEND

AÐ Field-Installed Accessory S Ð Standard from the Factory

*For size 018 and larger. ²Not used on 38HDS systems. **Heat pump systems only.

²²The outdoor units are equipped with 4 taps; one for each service valve, and one each on compressor suction and discharge.

3

Image 3
Contents Description Standard System FeaturesAir Conditioning 538A 538S 048 ShownContents FIELD-INSTALLED Accessory Description and Usage619B,D Standard Features and FIELD-INSTALLED AccessoriesModel Description System Capacities HspfSeer Unit Specifications Ð 538A and 538C Condensing UnitsUnit 538D Specifications Ð 538D Heat Pump UnitsUnit 619E Specifications Ð 538S Condensing UnitsSpecifications Ð 619E FAN Coil Units Unit 538S538 009 55.0 25.0 012 62.0 28.1 60.7 27.5 66.5 30.2 Unit WeightMinimum Mounting PAD Dimensions UnitUnit Operating Unit Operating Weight 538S Ft-in Dimensional DRAWING, Base Unit Ð 538S Condensing UnitsFt-in 024 048619E 009 Dimensional DRAWING, Base Unit Ð 619E009,012 FAN Coil Units619E Dimensional DRAWING, Base Unit Ð 619E018,024 FAN Coil UnitsElectrical Data Condensing Units Heat Pump UnitsMULTI-SPLIT Condensing Units Operating Voltage FAN Unit Electrical DataFAN Coil Units IndoorCooling-Only System Shown Cooling Only System Shown Condition ALL Units Application DataOutdoor Units ConditionFAN Coil Unit Equivalent Below Above Condensing Application DataMaximum Line Lengths Maximum Lift ÐHeat Pump System Piston Guide and Refrigerant Charges Fitting Loss in Equivalent FT for ElbowsChattleff Common Piston Sizes Cooling only System Piston Guide and Refrigerant ChargesIndoor Unit Above Outdoor Unit Change in Indoor Unit Piston Size For ElevationHorizontal Conguration Outdoor Unit Above Indoor UnitUnit FAN Speed AIR Throw DataCondensing Unit Sound Ratings FAN Coil High Speed ApproximateCompressor Relay ChartThermistor Equivalence Typical Wiring Schematic Ð 538A018,024 COOLING-ONLY SystemTemperatureResistance 500 11,400 32,500 Compressor K13Outdoor Fan K2 Compressor K1 Temperature Resistance 500 11,400 32,500 Typical Wiring Schematic Ð 538D018,024 Heat Pump SystemOperating Sequence Operating Sequence Electronic Control Defrost Regions Map Outdoor unit. Sensible heat capacity shall not be less than Bryant Day & Night Payne