Bryant 619E manual Specifications Ð 538A and 538C Condensing Units

Page 6

SPECIFICATIONS Ð 538A AND 538C CONDENSING UNITS

UNIT

538C

 

009

 

538C

 

012

 

538A

 

018

538A

 

024

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOMINAL CAPACITY (Tons)

3¤4

 

 

1

 

 

11¤2

 

2

 

OPERATING WEIGHT (lb)

55.0

 

62.0

 

150

 

154

 

REFRIGERANT TYPE

 

 

 

 

 

 

 

 

R-22

 

 

 

 

Control (Cooling)

 

 

Capillary

 

 

AccuRater Piston at Fan Coil Unit

Factory Charge (lb)*

1.5

 

 

1.5

 

 

4.6

 

5.3

 

COMPRESSOR TYPE

 

 

Carlyle Rotary

 

 

Tecumseh

Copeland

 

 

 

 

 

Reciprocating

Scroll

 

 

 

 

 

 

 

 

 

Model

EAA090111A

 

EBB120111A

 

AW5517G

ZR23K1

OUTDOOR FAN

 

 

 

 

 

 

 

Propeller Type

 

 

 

 

Rpm

1050

 

1050

 

850

 

850

 

Nominal Air Cfm (High Speed)

Ð

 

 

Ð

 

 

 

1720

 

1720

 

OUTDOOR COIL

 

 

 

 

 

Copper Tube, Aluminum Fin

 

 

 

Face Area (sq ft)...No. of Rows

3.5...1

 

3.5...2

 

6.1...1.5

6.1...2

Fins/in.

18

 

 

18

 

 

15

 

15

 

CONTROLS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High-Pressure (psig)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cutout

Ð

 

 

Ð

 

 

 

 

 

426 ±

7

 

 

Cut-in

Ð

 

 

Ð

 

 

 

 

 

320 ± 20

 

 

Low-Pressure (psig)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cutout

Ð

 

 

Ð

 

 

 

 

 

7 ±

3

 

 

Cut-in

Ð

 

 

Ð

 

 

 

 

 

22 ±

5

 

 

Fusible Plug

210 F

 

210 F

 

 

 

210 F

 

Control Voltage²

115

 

 

230

 

 

 

 

24

 

 

 

REFRIGERANT LINES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection Type

 

 

 

Flare

 

 

 

 

Sweat

 

Liquid Line OD (in.)

1¤4

 

 

1¤4

 

 

3¤8

 

3¤8

 

Vapor Line OD (in.)

1¤2

 

 

1¤2

 

 

5¤8

 

5¤8

 

Maximum Length (ft)

35

 

 

35

 

 

200

 

200

 

Maximum Lift (Fan Coil Above Outdoor) (ft)

16

 

 

16

 

 

65

 

65

 

Maximum Lift (Fan Coil Below Outdoor) (ft)

30

 

 

30

 

 

150

 

150

 

EXTERNAL FINISH

 

 

 

Grey

 

 

 

 

Alpine Mist (Beige)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*See System Piston Guide and Refrigerant Charges tables in Application section on page 21 for proper charge and piston with each fan coil type. Charge is based on duct-free fan coil requiring smallest amount of refrigerant and 25 ft of interconnecting line.

²24 v and a minimum of 40 va is provided in the fan coil unit.

6

Image 6
Contents 538A 538S 048 Shown Standard System FeaturesAir Conditioning DescriptionFIELD-INSTALLED Accessory Description and Usage ContentsStandard Features and FIELD-INSTALLED Accessories 619B,DModel Description System Capacities HspfSeer Specifications Ð 538A and 538C Condensing Units UnitSpecifications Ð 538D Heat Pump Units Unit 538DUnit 538S Specifications Ð 538S Condensing UnitsSpecifications Ð 619E FAN Coil Units Unit 619EUnit Weight 538 009 55.0 25.0 012 62.0 28.1 60.7 27.5 66.5 30.2Minimum Mounting PAD Dimensions UnitUnit Operating Unit Operating Weight 048 Dimensional DRAWING, Base Unit Ð 538S Condensing UnitsFt-in 024 538S Ft-inDimensional DRAWING, Base Unit Ð 619E009,012 FAN Coil Units 619E 009Dimensional DRAWING, Base Unit Ð 619E018,024 FAN Coil Units 619EElectrical Data Condensing Units Heat Pump UnitsMULTI-SPLIT Condensing Units Indoor Electrical DataFAN Coil Units Operating Voltage FAN UnitCooling-Only System Shown Cooling Only System Shown Condition Application DataOutdoor Units Condition ALL UnitsMaximum Lift Ð Application DataMaximum Line Lengths FAN Coil Unit Equivalent Below Above CondensingCooling only System Piston Guide and Refrigerant Charges Fitting Loss in Equivalent FT for ElbowsChattleff Common Piston Sizes Heat Pump System Piston Guide and Refrigerant ChargesOutdoor Unit Above Indoor Unit Change in Indoor Unit Piston Size For ElevationHorizontal Conguration Indoor Unit Above Outdoor UnitFAN Coil High Speed Approximate AIR Throw DataCondensing Unit Sound Ratings Unit FAN SpeedRelay Chart CompressorCompressor K13 Typical Wiring Schematic Ð 538A018,024 COOLING-ONLY SystemTemperatureResistance 500 11,400 32,500 Thermistor EquivalenceOutdoor Fan K2 Compressor K1 Typical Wiring Schematic Ð 538D018,024 Heat Pump System Temperature Resistance 500 11,400 32,500Operating Sequence Operating Sequence Electronic Control Defrost Regions Map Outdoor unit. Sensible heat capacity shall not be less than Bryant Day & Night Payne