Bryant 619E manual Cooling Only System Shown

Page 18

TYPICAL INSTALLATION Ð HIGH-WALL SYSTEMS, 18,000 AND 24,000 BTUH

(Cooling Only System Shown)

LEGEND

NEC Ð National Electrical Code

Piping

Line Voltage

24 V

Thermistor

*Standard. ²Field supplied.

NOTES:

1. All piping must follow standard refrigerant piping techniques.

2. All wiring must comply with the applicable local and national codes.

3. Liquid line need not be insulated.

4. Wiring and piping shown are gen- eral points-of-connection guides only and are not intended for a speci®c installation.

5. Insulate condensate drain if in- stalled in a conditioned space.

18

Image 18
Contents 538A 538S 048 Shown Standard System FeaturesAir Conditioning DescriptionFIELD-INSTALLED Accessory Description and Usage ContentsStandard Features and FIELD-INSTALLED Accessories 619B,DModel Description System Capacities HspfSeer Specifications Ð 538A and 538C Condensing Units UnitSpecifications Ð 538D Heat Pump Units Unit 538DUnit 538S Specifications Ð 538S Condensing UnitsSpecifications Ð 619E FAN Coil Units Unit 619EUnit Weight 538 009 55.0 25.0 012 62.0 28.1 60.7 27.5 66.5 30.2Minimum Mounting PAD Dimensions UnitUnit Operating Unit Operating Weight 048 Dimensional DRAWING, Base Unit Ð 538S Condensing UnitsFt-in 024 538S Ft-inDimensional DRAWING, Base Unit Ð 619E009,012 FAN Coil Units 619E 009Dimensional DRAWING, Base Unit Ð 619E018,024 FAN Coil Units 619EElectrical Data Condensing Units Heat Pump UnitsMULTI-SPLIT Condensing Units Indoor Electrical DataFAN Coil Units Operating Voltage FAN UnitCooling-Only System Shown Cooling Only System Shown Condition Application DataOutdoor Units Condition ALL UnitsMaximum Lift Ð Application DataMaximum Line Lengths FAN Coil Unit Equivalent Below Above CondensingCooling only System Piston Guide and Refrigerant Charges Fitting Loss in Equivalent FT for ElbowsChattleff Common Piston Sizes Heat Pump System Piston Guide and Refrigerant ChargesOutdoor Unit Above Indoor Unit Change in Indoor Unit Piston Size For ElevationHorizontal Conguration Indoor Unit Above Outdoor UnitFAN Coil High Speed Approximate AIR Throw DataCondensing Unit Sound Ratings Unit FAN SpeedRelay Chart CompressorCompressor K13 Typical Wiring Schematic Ð 538A018,024 COOLING-ONLY SystemTemperatureResistance 500 11,400 32,500 Thermistor EquivalenceOutdoor Fan K2 Compressor K1 Typical Wiring Schematic Ð 538D018,024 Heat Pump System Temperature Resistance 500 11,400 32,500Operating Sequence Operating Sequence Electronic Control Defrost Regions Map Outdoor unit. Sensible heat capacity shall not be less than Bryant Day & Night Payne