Bryant 619E manual Unit Operating, Minimum Mounting PAD Dimensions

Page 10

DIMENSIONAL DRAWING Ð BASE UNIT Ð 538A018-024 CONDENSING UNITS

UNIT

A

 

 

B

 

C

 

 

D

 

E

 

 

 

F

 

 

 

G

 

 

 

H

538A

ft-in.

 

mm

 

 

ft-in.

mm

 

ft-in.

 

mm

ft-in.

mm

 

ft-in.

mm

ft-in.

mm

 

ft-in.

mm

ft-in.

mm

018

2-11¤8

638.2

 

3-015¤16

 

938.2

 

1-29¤16

 

369.9

1-4

406.4

1-117¤16

595.3

1-53¤16

436.6

1-51¤2

444.5

1-81¤8

511.2

024

2-11¤8

638.2

 

3-015¤16

 

938.2

 

1-29¤16

 

369.9

1-4

406.4

1-117¤16

595.3

1-53¤16

436.6

1-51¤2

444.5

 

1-81¤8

511.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

 

J

 

K

 

 

L

 

 

 

M

 

N

 

 

R

 

 

S

 

OPERATING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WT

538A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ft-in.

 

mm

 

ft-in.

 

mm

 

 

ft-in.

mm

ft-in.

mm

ft-in.

mm

ft-in.

mm

ft-in.

 

 

mm

 

 

Lb

 

 

kg

 

 

 

 

 

 

 

 

 

 

 

 

018

1-11¤4

 

336.6

 

0-65¤8

168.3

 

0-1013¤16

274.6

0-05¤8

15.00

0-03¤8

9.52

0-41¤2

115.0

0-61¤2

166.0

 

150

 

68.0

024

1-27¤16

 

366.7

 

0-63¤4

 

171.4

 

1- 0

 

304.8

0-05¤8

15.00

0-03¤8

9.52

0-41¤2

115.0

0-61¤2

 

166.0

 

154

 

69.0

MINIMUM MOUNTING PAD DIMENSIONS

Support Feet

Snow Stand

Ice Stand

ft-in.

mm

ft-in.

mm

ft-in.

mm

1-11 x

584.2 x

2-2 x

660.4 x

2-2 x

660.4 x

3-6

1066.8

3-6

1066.8

3-6

1066.8

NOTES:

1. Required clearances, with coil facing wall, allow 6 in. minimum clearance on coil side and coil end, and 3 ft minimum clearance on compressor end and fan side. With fan facing wall, allow 8 in. mini- mum clearance on fan side and coil end, and 3 ft minimum clearance on compressor end and coil side. With multi-unit application, arrange units so discharge of one does not enter inlet of another.

2. Dimensions in parenthesis are in millimeters.

3. Center of Gravity.

10

Image 10
Contents 538A 538S 048 Shown Standard System FeaturesAir Conditioning DescriptionFIELD-INSTALLED Accessory Description and Usage ContentsStandard Features and FIELD-INSTALLED Accessories 619B,DModel Description Hspf System CapacitiesSeer Specifications Ð 538A and 538C Condensing Units UnitSpecifications Ð 538D Heat Pump Units Unit 538DUnit 538S Specifications Ð 538S Condensing UnitsSpecifications Ð 619E FAN Coil Units Unit 619EUnit Weight 538 009 55.0 25.0 012 62.0 28.1 60.7 27.5 66.5 30.2Unit Minimum Mounting PAD DimensionsUnit Operating Unit Operating Weight 048 Dimensional DRAWING, Base Unit Ð 538S Condensing UnitsFt-in 024 538S Ft-inDimensional DRAWING, Base Unit Ð 619E009,012 FAN Coil Units 619E 009Dimensional DRAWING, Base Unit Ð 619E018,024 FAN Coil Units 619EHeat Pump Units Electrical Data Condensing UnitsMULTI-SPLIT Condensing Units Indoor Electrical DataFAN Coil Units Operating Voltage FAN UnitCooling-Only System Shown Cooling Only System Shown Condition Application DataOutdoor Units Condition ALL UnitsMaximum Lift Ð Application DataMaximum Line Lengths FAN Coil Unit Equivalent Below Above CondensingCooling only System Piston Guide and Refrigerant Charges Fitting Loss in Equivalent FT for ElbowsChattleff Common Piston Sizes Heat Pump System Piston Guide and Refrigerant ChargesOutdoor Unit Above Indoor Unit Change in Indoor Unit Piston Size For ElevationHorizontal Conguration Indoor Unit Above Outdoor UnitFAN Coil High Speed Approximate AIR Throw DataCondensing Unit Sound Ratings Unit FAN SpeedRelay Chart CompressorCompressor K13 Typical Wiring Schematic Ð 538A018,024 COOLING-ONLY SystemTemperatureResistance 500 11,400 32,500 Thermistor EquivalenceOutdoor Fan K2 Compressor K1 Typical Wiring Schematic Ð 538D018,024 Heat Pump System Temperature Resistance 500 11,400 32,500Operating Sequence Operating Sequence Electronic Control Defrost Regions Map Outdoor unit. Sensible heat capacity shall not be less than Bryant Day & Night Payne