Bryant 589A, 588A user manual Contents, Safety Considerations, General

Page 1

installation, start-up and service instructions

588A

Sizes 018-060

589A

SINGLE PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Sizes 024-060

CONTENTS

Page

SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . 1

General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

RECEIVING AND INSTALLATION . . . . . . . . . . . . . . . . . 10-22 I. Step 1 Ð Check Equipment . . . . . . . . . . . . . . . . . 10 II. Step 2 Ð Provide Unit Support . . . . . . . . . . . . . . 10 III. Step 3 Ð Field Fabricate Ductwork . . . . . . . . . . . 10 IV. Step 4 Ð Provide Clearances . . . . . . . . . . . . . . . . 10 V. Step 5 Ð Rig and Place Unit . . . . . . . . . . . . . . . . 10 VI. Step 6 Ð Connect Condensate Drain . . . . . . . . . 13 VII. Step 7 Ð Install Flue Hood . . . . . . . . . . . . . . . . . . 13 VIII. Step 8 Ð Install Gas Piping . . . . . . . . . . . . . . . . . 13

IX. Step 9 Ð Install Duct Connections . . . . . . . . . . . 16 X. Step 10 Ð Install Electrical Connections . . . . . . 18

PRE-START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22,23

START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23-44 I. Check for Refrigerant Leaks . . . . . . . . . . . . . . . . . 23

II. Start Up Heating Section and

Make Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . 23

III. Start Up Cooling Section and

Make Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . 26

MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44-47

I. Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

II. Unit Top Removal . . . . . . . . . . . . . . . . . . . . . . . . . . 45

III. Evaporator Blower and Motor . . . . . . . . . . . . . . . . 45

IV. Flue Gas Passageways . . . . . . . . . . . . . . . . . . . . . 45

V. Combustion-Air Blower . . . . . . . . . . . . . . . . . . . . . 46

VI. Limit Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

VII. Burner Ignition . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

VIII. Main Burners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

IX. Condenser Coil, Evaporator Coil, and

Condensate Drain Pan . . . . . . . . . . . . . . . . . . . . . . 47

X. Condenser Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

XI. Electrical Controls and Wiring . . . . . . . . . . . . . . . 47

XII. Refrigerant Circuit . . . . . . . . . . . . . . . . . . . . . . . . . 47

XIII. Gas Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

XIV. Evaporator Air¯ow . . . . . . . . . . . . . . . . . . . . . . . . . 47

XV. Metering Device Ð Acutrol™ Device . . . . . . . . . . 47

XVI. Liquid Line Strainer . . . . . . . . . . . . . . . . . . . . . . . . 47

TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-50

START-UP CHECKLIST . . . . . . . . . . . . . . . . . . . . . . . . . . CL-1

NOTE TO INSTALLER Ð Before the installation, READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY. Also, make sure the User's Manual and Replacement Guide are left with the unit after installation. This unit is NOT to be used for temporary heating of buildings or structures un- der construction.

SAFETY CONSIDERATIONS

Installation and servicing of air-conditioning equipment can be hazardous due to system pressure and electrical compo- nents. Only trained and quali®ed personnel should install, repair, or service air-conditioning equipment.

Cancels: II 588A-18-8

II 588A-18-9

 

9/15/98

Fig. 1 Ð Unit 589A Shown With Optional Base Rail

Untrained personnel can perform basic maintenance func- tions of cleaning coils and ®lters. All other operations should be performed by trained service personnel. When working on air-conditioning equipment, observe precautions in the lit- erature, tags and labels attached to the unit, and other safety precautions that may apply.

Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for unbrazing operations. Have ®re ex- tinguisher available for all brazing operations.

WARNING: Improper installation, adjustment, alter- ation, service, maintenance, or use can cause carbon mon- oxide poisoning, ®re, or an explosion which can result in personal injury or unit damage. Consult a quali®ed installer, service agency, or gas supplier for informa- tion or assistance. The quali®ed installer or agency must use only factory-authorized kits or accessories when modi- fying this product.

WARNING: Before performing service or mainte- nance operations on unit, turn off gas supply then unit main power switch. Electrical shock could cause per- sonal injury.

GENERAL

The 588A, 589A units (see Fig. 1) are fully self-contained, com- bination Category I gas heating/electric cooling units de- signed for outdoor installation. See Fig. 2-9 (pages 2-9) for unit dimensions. All unit sizes have discharge openings for both horizontal and down¯ow con®gurations, and are factory shipped with all 4 duct openings covered. Units may be in- stalled either on a rooftop or a ground-level cement slab. See Fig. 10 for roof curb dimensions.

Image 1
Contents Safety Considerations ContentsGeneral Ð2Ð 588A018-042 Without Base Rail, Unit DimensionsÐ3Ð 588A018-042 With Optional Base Rail, Unit DimensionsÐ4Ð 588A048,060 Without Base Rail, Unit DimensionsÐ5Ð 588A048,060 With Optional Base Rail, Unit DimensionsÐ6Ð 589A024-036 Without Base Rail, Unit DimensionsÐ7Ð 589A024-036 With Optional Base Rail, Unit DimensionsÐ8Ð 589A042-060 Without Base Rail, Unit DimensionsÐ9Ð 589A042-060 With Optional Base Rail, Unit DimensionsII. Ð Provide Unit Support Receiving and Installation Check EquipmentIII. Ð Field Fabricate Ductwork IV. Ð Provide ClearancesPart Number Ð11ÐCurb Unit MAX WeightUnit VIII. Ð Install GAS Piping VII. Ð Install Flue HoodUnits With Optional Base Rail VI. Ð Connect Condensate DrainÐ14Ð Physical Data Ð Unit 588AÐ15Ð Physical Data Ð Unit 589AConguring Units for Down¯ow Vertical Discharge IX. Ð Install Duct ConnectionsÐ17Ð Maximum Gas Flow CapacityInternal Length of PIPE, FT² Iron Pipe Diameter Size High-Voltage Connections Install Electrical ConnectionsÐ19Ð Ð Electrical Data Ð Unit 588AÐ20Ð Ð Electrical Data Ð Unit 589ARLA LRA FLA High- and Control-Voltage Connections Special Procedures for 208-V OperationPRE-START-UP Transformer ProtectionAdjust Gas Input II. Start UP Heating Section and Make AdjustmentsSTART-UP Check for Refrigerant Leaks Check Heating ControlGAS Supply Pressure Manifold Natural GAS Propane Number Rated Gas Inputs at Indicated Manifold PressuresPressure OrificesCheck Burner Flame Heating Temperature Rise F InputÐ25Ð III. Start UP Cooling Section and Make Adjustments Ð27Ð 208/230-1-60 Wiring Diagram, Units 588A018-060Ð28Ð 208/230-3-60 Wiring Diagram, Units 588A030-060Ð29Ð 460-3-60 Wiring Diagram, Units 588A036-060Ð30Ð 208/230-1-60 Wiring Diagram, Units 589A024-042Ð31Ð 208/230-1-60 Wiring Diagram, Units 589A048,060Ð32Ð 208/230-3-60 Wiring Diagram, Units 589A036-042Ð33Ð 208/230-3-60 Wiring Diagram, Units 589A048,060Ð34Ð 460-3-60 Wiring Diagram, Units 589A036-048Indoor Air¯ow and Air¯ow Adjustments Checking and Adjusting Refrigerant ChargeSpeed Ð Superheat Charging Table, 588A024 Ð Superheat Charging Table, 588A018Ð36Ð Ð Superheat Charging Table, 588A036 Ð Superheat Charging Table, 588A030Ð Superheat Charging Table, 588A042 Ð37ÐÐ38Ð Ð Superheat Charging Table, 588A060Ð Superheat Charging Table, 589A030 Ð Superheat Charging Table, 589A024Ð Superheat Charging Table, 589A036 Ð39ÐÐ Superheat Charging Table, 589A048 Ð Superheat Charging Table, 589A042Ð Superheat Charging Table, 589A060 Ð40ÐÐ41Ð Required Suction-Tube Temperature FÐ42Ð Unit 589A Ð43ÐWet Coil Pressure Drop MaintenanceCooling Sequence of Operation Unit Size Airflow Pressure DropII. Unit TOP Removal AIR FilterIII. Evaporator Blower and Motor IV. Flue GAS PassagewaysCOMBUSTION-AIR Blower VI. Limit SwitchVII. Burner Ignition VIII. Main BurnersCondenser FAN XI. Electrical Controls and WiringXII. Refrigerant Circuit XIII. GAS InputSymptom Cause Remedy TroubleshootingPoor ¯ame characteristics IFM runs when itIntegrated control MotorLED OFF Service TrainingPage Temperatures START-UP ChecklistPreliminary Information III. START-UP Electrical
Related manuals
Manual 27 pages 52.72 Kb

589A, 588A specifications

The Bryant 588A is a high-efficiency gas furnace celebrated for its advanced technology and superior performance in residential heating. Known for its reliability and durable construction, this model is ideal for homeowners looking for warmth and comfort during colder months.

One of the standout features of the Bryant 588A is its remarkable AFUE (Annual Fuel Utilization Efficiency) rating, which can reach up to 96.5%. This high efficiency means that a significant portion of the fuel consumed is converted into usable heat, leading to lower energy bills and a reduced carbon footprint. The furnace utilizes a two-stage heating system, which improves comfort levels by providing more consistent temperatures and reducing the frequency of temperature swings in the home.

Another notable characteristic is the incorporation of a multi-speed blower motor. This innovation enhances airflow and optimizes energy use by adjusting the fan speed according to the heating needs of the home. The variable speed operation also helps to minimize noise levels, creating a quieter environment compared to traditional single-speed furnaces.

The Bryant 588A features an advanced control system that allows for better system management and can be integrated with smart home technologies. This allows homeowners to monitor and adjust their heating settings remotely, offering convenience and efficiency. Additionally, the furnace is compatible with Bryant’s Evolution System, which provides advanced diagnostic features and improved energy performance.

Durability is a key characteristic of the Bryant 588A, as it is constructed with a heavy-duty cabinet designed to withstand the rigors of daily use and harsh weather conditions. The unit also includes a corrosion-resistant heat exchanger, ensuring longevity and reliability.

Furthermore, the Bryant 588A operates quietly, thanks to its insulated cabinet and advanced design. This feature is especially appreciated by homeowners seeking a peaceful living environment free from disruptive noises typically associated with heating systems.

In summary, the Bryant 588A gas furnace combines high efficiency, innovative technology, and durable construction. Its effective heating capabilities paired with user-friendly features make it a smart investment for anyone looking to enhance their home heating system while enjoying lower energy costs and increased comfort.