Bryant 588A user manual Physical Data Ð Unit 589A, Ð15Ð

Page 15

Table 2 Ð Physical Data Ð Unit 589A

UNIT SIZE 589A

 

024040

024060

030040

030060

 

030080

 

036060

036080

036100

036120

NOMINAL CAPACITY (ton)

 

2

 

2

21¤2

21¤2

 

21¤2

 

 

3

 

3

 

3

 

3

OPERATING WEIGHT (lb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Without Base Rail

 

333

345

336

348

 

348

 

366

366

378

378

With Optional Base Rail

357

369

360

372

 

372

 

390

390

402

402

COMPRESSORS

 

 

 

 

 

 

 

 

 

 

Scroll

 

 

 

 

 

 

 

 

Quantity

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

REFRIGERANT (R-22)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Charge (lb)

 

 

3.9

 

3.9

 

4.5

 

4.5

 

 

4.5

 

 

5.4

 

5.4

 

5.4

 

5.4

REFRIGERANT METERING DEVICE

 

 

 

 

 

 

 

 

Acutrol™ Device

 

 

 

 

 

 

 

 

Ori®ce ID (in.)

 

.034

.034

.030

.030

 

.030

 

.032

.032

.032

.032

CONDENSER COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rows...Fins/in.

 

2

...17

2

...17

2

...17

2

...17

 

2

...17

 

2

...17

2

...17

2

...17

2

...17

Face Area (sq ft)

 

 

7.0

 

7.0

 

7.0

 

7.0

 

 

7.0

 

 

7.0

 

7.0

 

7.0

 

7.0

CONDENSER FAN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal Cfm

 

2200

2200

2200

2200

 

2200

 

2200

2200

2200

2200

Diameter (in.)

 

 

20

 

20

 

20

 

20

 

 

20

 

 

20

 

20

 

20

 

20

Motor Hp (Rpm)

 

1¤4 (1100)

1¤4 (1100)

1¤4 (1100)

1¤4 (1100)

 

1¤4 (1100)

 

1¤4 (1100)

1¤4 (1100)

1¤4 (1100)

1¤4 (1100)

EVAPORATOR COIL

 

2

...15

2

...15

3

...15

3

...15

 

3

...15

 

4

...15

4

...15

4

...15

4

...15

Rows Fins/in.

 

 

 

Face Area (sq ft)

 

 

3.6

 

3.6

 

2.7

 

2.7

 

 

2.7

 

 

3.6

 

3.6

 

3.6

 

3.6

EVAPORATOR FAN*

 

 

 

 

 

 

 

 

 

 

Direct Drive

 

 

 

 

 

 

 

 

Nominal Air¯ow (Cfm)

800

800

1000

1000

 

1000

 

1200

1200

1200

1200

Size (in.)

 

10 x 10

10 x 10

10 x 10

10 x 10

 

10 x 10

 

10 x 10

10 x 10

10 x 10

10 x 10

Motor Hp

 

 

1¤4

 

1¤4

 

1¤4

 

1¤4

 

 

1¤4

 

 

1¤2

 

1¤2

 

1¤2

 

1¤2

FURNACE SECTION²

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner Ori®ce (Qty...

drill size)

1

...32

2

...41

1

...32

2

...40

 

2

...32

 

2

...40

2

...32

2

...30

3

...32

Natural Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner Ori®ce (Qty...

drill size)

1

...41

2

...47

1

...41

2

...47

 

2

...42

 

2

...47

2

...42

2

...40

3

...42

Propane Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RETURN-AIR FILTERS (in.)**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disposable

 

24 x 24

24 x 24

24 x 24

24 x 24

 

24 x 24

 

24 x 24

24 x 24

24 x 24

24 x 24

UNIT SIZE 589A

 

042060

042080

042100

042120

048080

048100

048120

048140

060080

060100

060120

060140

NOMINAL CAPACITY (ton)

31¤2

31¤2

31¤2

31¤2

 

4

 

4

 

4

 

4

 

5

 

5

 

5

 

5

OPERATING WEIGHT (lb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Without Base Rail

 

391

391

403

403

422

434

434

434

453

465

465

465

With Optional Base Rail

415

415

427

427

446

458

458

458

477

489

489

489

COMPRESSORS

 

 

 

 

 

 

 

 

 

 

 

 

Scroll

 

 

 

 

 

 

 

 

 

 

 

Quantity

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT (R-22)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Charge (lb)

 

 

5.7

 

5.7

 

5.7

 

5.7

 

5.8

 

5.8

 

5.8

 

5.8

7.00

7.00

7.00

7.00

REFRIGERANT METERING

 

 

 

 

 

 

 

 

 

 

Acutrol Device

 

 

 

 

 

 

 

 

 

 

DEVICE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ori®ce ID (in.)

 

.034

.034

.034

.034

.034

.034

.034

.034

.030

.030

.030

.030

CONDENSER COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rows...Fins/in.

 

2

...17

2

...17

2

...17

2

...17

2

...17

2

...17

2

...17

2

...17

2

...17

2

...17

2

...17

2

...17

Face Area (sq ft)

 

 

8.7

 

8.7

 

8.7

 

8.7

 

8.7

 

8.7

 

8.7

 

8.7

8.67

8.67

8.67

8.67

CONDENSER FAN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal Cfm

 

2400

2400

2400

2400

2400

2400

2400

2400

2400

2400

2400

2400

Diameter (in.)

 

 

20

 

20

 

20

 

20

 

20

 

20

 

20

 

20

 

20

 

20

 

20

 

20

Motor Hp (Rpm)

 

1¤4 (1100)

1¤4 (1100)

1¤4 (1100)

1¤4 (1100)

1¤4 (1100)

1¤4 (1100)

1¤4 (1100)

1¤4 (1100)

1¤3 (1050)

1¤3 (1050)

1¤3 (1050)

1¤3 (1050)

EVAPORATOR COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rows Fins/in.

 

3

...15

3

...15

3

...15

3

...15

4

...15

4

...15

4

...15

4

...15

4...

15

4...

15

4...

15

4...

15

Face Area (sq ft)

 

 

4.4

 

4.4

 

4.4

 

4.4

 

4.4

 

4.4

 

4.4

 

4.4

4.44

4.44

4.44

4.44

EVAPORATOR FAN*

 

 

 

 

 

 

 

 

 

 

 

Direct Drive

 

 

 

 

 

 

 

 

 

 

Nominal Air¯ow (Cfm)

1400

1400

1400

1400

1600

1600

1600

1600

1995

1995

1995

1995

Size (in.)

 

10 x 10

10 x 10

10 x 10

10 x 10

10 x 10

10 x 10

10 x 10

10 x 10

10 x 11

10 x 11

10 x 11

10 x 11

Motor Hp

 

 

3¤4

 

3¤4

 

3¤4

 

3¤4

 

3¤4

 

3¤4

 

3¤4

 

3¤4

 

1

 

1

 

1

 

1

FURNACE SECTION²

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner Ori®ce (Qty...

drill size)

2

...40

2

...32

2

...30

3

...32

2

...32

2

...30

3

...32

3

...31

2...

32

2...

30

3...

32

3...

31

Natural Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner Ori®ce (Qty...

drill size)

2

...47

2

...42

2

...40

3

...42

2

...42

2

...40

3

...42

3

...40

3...

42

2...

40

3...

42

3...

40

Propane Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RETURN-AIR FILTERS (in.)**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disposable

 

24 x 30

24 x 30

24 x 30

24 x 30

24 x 30

24 x 30

24 x 30

24 x 30

24 x 30

24 x 30

24 x 30

24 x 30

*Size 048 evaporator fan is equipped with a 460-v or integrated control motor (ICM). Size 060 evaporator fan is equipped with an ICM only. The ICM provides variable speed.

²Based on an altitude of 0-2000 feet.

**Required ®lter sizes shown are based on the ARI (Air Conditioning & Refrigeration Institute) rated heating air¯ow at a velocity of 300 ft/min for throwaway type or 450 ft/min for high-capacity type. For non-standard air ®lters, air ®lter pressure drop must not exceed 0.08 in. wg.

Ð15Ð

Image 15
Contents Contents Safety ConsiderationsGeneral Ð2Ð 588A018-042 Without Base Rail, Unit DimensionsÐ3Ð 588A018-042 With Optional Base Rail, Unit DimensionsÐ4Ð 588A048,060 Without Base Rail, Unit DimensionsÐ5Ð 588A048,060 With Optional Base Rail, Unit DimensionsÐ6Ð 589A024-036 Without Base Rail, Unit DimensionsÐ7Ð 589A024-036 With Optional Base Rail, Unit DimensionsÐ8Ð 589A042-060 Without Base Rail, Unit DimensionsÐ9Ð 589A042-060 With Optional Base Rail, Unit DimensionsIV. Ð Provide Clearances Receiving and Installation Check EquipmentII. Ð Provide Unit Support III. Ð Field Fabricate DuctworkÐ11Ð Part NumberCurb Weight Unit MAXUnit VI. Ð Connect Condensate Drain VII. Ð Install Flue HoodVIII. Ð Install GAS Piping Units With Optional Base RailÐ14Ð Physical Data Ð Unit 588AÐ15Ð Physical Data Ð Unit 589AConguring Units for Down¯ow Vertical Discharge IX. Ð Install Duct ConnectionsMaximum Gas Flow Capacity Ð17ÐInternal Length of PIPE, FT² Iron Pipe Diameter Size High-Voltage Connections Install Electrical ConnectionsÐ19Ð Ð Electrical Data Ð Unit 588AÐ Electrical Data Ð Unit 589A Ð20ÐRLA LRA FLA High- and Control-Voltage Connections Special Procedures for 208-V OperationPRE-START-UP Transformer ProtectionCheck Heating Control II. Start UP Heating Section and Make AdjustmentsAdjust Gas Input START-UP Check for Refrigerant LeaksOrifices Rated Gas Inputs at Indicated Manifold PressuresGAS Supply Pressure Manifold Natural GAS Propane Number PressureHeating Temperature Rise F Input Check Burner FlameÐ25Ð III. Start UP Cooling Section and Make Adjustments Ð27Ð 208/230-1-60 Wiring Diagram, Units 588A018-060Ð28Ð 208/230-3-60 Wiring Diagram, Units 588A030-060Ð29Ð 460-3-60 Wiring Diagram, Units 588A036-060Ð30Ð 208/230-1-60 Wiring Diagram, Units 589A024-042Ð31Ð 208/230-1-60 Wiring Diagram, Units 589A048,060Ð32Ð 208/230-3-60 Wiring Diagram, Units 589A036-042Ð33Ð 208/230-3-60 Wiring Diagram, Units 589A048,060Ð34Ð 460-3-60 Wiring Diagram, Units 589A036-048Checking and Adjusting Refrigerant Charge Indoor Air¯ow and Air¯ow AdjustmentsSpeed Ð Superheat Charging Table, 588A018 Ð Superheat Charging Table, 588A024Ð36Ð Ð37Ð Ð Superheat Charging Table, 588A030Ð Superheat Charging Table, 588A036 Ð Superheat Charging Table, 588A042Ð38Ð Ð Superheat Charging Table, 588A060Ð39Ð Ð Superheat Charging Table, 589A024Ð Superheat Charging Table, 589A030 Ð Superheat Charging Table, 589A036Ð40Ð Ð Superheat Charging Table, 589A042Ð Superheat Charging Table, 589A048 Ð Superheat Charging Table, 589A060Ð41Ð Required Suction-Tube Temperature FÐ42Ð Unit 589A Ð43ÐUnit Size Airflow Pressure Drop MaintenanceWet Coil Pressure Drop Cooling Sequence of OperationIV. Flue GAS Passageways AIR FilterII. Unit TOP Removal III. Evaporator Blower and MotorVIII. Main Burners VI. Limit SwitchCOMBUSTION-AIR Blower VII. Burner IgnitionXIII. GAS Input XI. Electrical Controls and WiringCondenser FAN XII. Refrigerant CircuitSymptom Cause Remedy TroubleshootingMotor IFM runs when itPoor ¯ame characteristics Integrated controlLED OFF Service TrainingPage III. START-UP Electrical START-UP ChecklistTemperatures Preliminary Information
Related manuals
Manual 27 pages 52.72 Kb

589A, 588A specifications

The Bryant 588A is a high-efficiency gas furnace celebrated for its advanced technology and superior performance in residential heating. Known for its reliability and durable construction, this model is ideal for homeowners looking for warmth and comfort during colder months.

One of the standout features of the Bryant 588A is its remarkable AFUE (Annual Fuel Utilization Efficiency) rating, which can reach up to 96.5%. This high efficiency means that a significant portion of the fuel consumed is converted into usable heat, leading to lower energy bills and a reduced carbon footprint. The furnace utilizes a two-stage heating system, which improves comfort levels by providing more consistent temperatures and reducing the frequency of temperature swings in the home.

Another notable characteristic is the incorporation of a multi-speed blower motor. This innovation enhances airflow and optimizes energy use by adjusting the fan speed according to the heating needs of the home. The variable speed operation also helps to minimize noise levels, creating a quieter environment compared to traditional single-speed furnaces.

The Bryant 588A features an advanced control system that allows for better system management and can be integrated with smart home technologies. This allows homeowners to monitor and adjust their heating settings remotely, offering convenience and efficiency. Additionally, the furnace is compatible with Bryant’s Evolution System, which provides advanced diagnostic features and improved energy performance.

Durability is a key characteristic of the Bryant 588A, as it is constructed with a heavy-duty cabinet designed to withstand the rigors of daily use and harsh weather conditions. The unit also includes a corrosion-resistant heat exchanger, ensuring longevity and reliability.

Furthermore, the Bryant 588A operates quietly, thanks to its insulated cabinet and advanced design. This feature is especially appreciated by homeowners seeking a peaceful living environment free from disruptive noises typically associated with heating systems.

In summary, the Bryant 588A gas furnace combines high efficiency, innovative technology, and durable construction. Its effective heating capabilities paired with user-friendly features make it a smart investment for anyone looking to enhance their home heating system while enjoying lower energy costs and increased comfort.