GLOSSARY
Become familiar with these terms before operating the unit. CFM: Cubic feet per minute.
SCFM: Standard cubic feet per minute; a unit of measure of air delivery.
PSIG: Pounds per square inch gauge; a unit of measure of pressure.
Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety.
Branch Circuit: Circuit carrying electricity from electrical panel to outlet.
DUTY CYCLE
Air compressors should be operated on not more than a 50% duty cycle. This means an air compressor that pumps air more than 50% of one hour is considered misuse, because the air compressor is undersized for the required air demand. Maximum compressor pumping time per hour is 30 minutes.
SPECIFICATIONS | |
Model No. |
|
Horsepower Peak | 2 |
Bore | 1.875" |
Stroke | 1.250" |
Voltage/Hertz/ Phase | 120V/60Hz/1Ph |
Minimum Branch Circuit Requirement | 10 amps |
*Fuse Type | Time Delay |
Air Tank Capacity | 3 gallons |
Approximate | 100 |
Approximate | 125 |
SCFM @ 40 PSIG | 3.7 |
SCFM @ 90 PSIG | 2.6 |
*A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit on which the air compressor is operated. If compressor is connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses should be marked “D” in Canada and “T” in the US.
ACCESSORIES
Accessories for this unit are available at the store the unit was purchased.
D27456 | 8- ENG |