Emerson SZO56, SZO44 Troubleshooting Guide, Motor Winding Resistance, Motor winding resistance

Page 31

Dual-Compressor Module

Troubleshooting

5.0Troubleshooting

This section offers tips for troubleshooting.

5.1Troubleshooting Guide

Refer to Table 4 for recommended solutions to typical problems.

Table 4

Troubleshooting

Problem

 

Recommended Actions

Low Inlet

 

• Closed gas inlet valve.

Gas Pressure

• Restricted or insufficient gas supply.

Fault

 

• Blocked inlet filter/screen (located internally on the Compressor Module inlet block).

 

 

 

 

• Blocked air flow across oil cooler.

High Oil

 

• Ensure cooling fans are operating when the unit is running and up to temperature; at

Temperature

approximately 180°F (82°C), fans should start to run at minimum speed.

Fault

 

• Ensure adequate oil level in first-stage separator (see 4.3 - Checking the Oil Level on

 

 

 

 

page 19).

High Discharge

• Restricted discharge and bypass valve fault.

Pressure Fault

 

VFD Fault

 

• The drive LED will display the specific fault

5.2Motor Winding Resistance

Table 5

Motor winding resistance

 

Compressor

 

 

Model

 

Motor Winding Resistance

C1A and C3A

Phase-to-phase

= 1.2 to 1.4 ohms

C2A

 

Phase-to-phase

= 0.7 ohms

All Compressor

Phase-to-ground

= Infinity

Modules

 

 

 

 

25

2006SSD-75 R4 (10/10)

Image 31
Contents Copeland Scroll Compressor Module Page Table of Contents Appendix A Material Data Safety Sheet Figures Compressor Module Nomenclature Important Safety Information Safety Symbols Used in This Manual Safety Alert SymbolIntroduction Compressor ModuleOil coolers with fans Compressor Package CompressorInlet gas scrubber for liquid removal Required Component-Inlet Gas Scrubber Installation GuidelinesGeneral Installation Guidelines Inlet and Discharge PressuresBarg Setting Ambient Temperature RangeModule Weight Lbs. kg Compressor Module Dimensions, in. mm Installation Clearance and DimensionsCode Description Process and Instrumentation Diagrams P&IDsGeneral Considerations SwitchesSwitchStatus Electrical ControlsBrushless DC Fan Oil Cooler Fan ControlSZO44 Temperature ControlDrive Variable SpeedCompressor Power data based on 480VAC Variable Speed Typical Compressor Module power supply requirementsElectrical Requirements Control Circuit Terminations WiringOperation Pre-Startup ChecklistPost-Startup Checklist Initial Startup Compressor ModuleCheck for These Conditions Under Normal Operation Maintenance Routine MaintenanceMaintenance summary Maintenance Tools Maintenance ToolsOil Level Guidelines Maximum Speed Checking the Oil LevelOil Capacity and Type Oil Level Guidelines Minimum SpeedTopping Off the Oil Level Adding and Removing OilAdding Oil Draining Oil Changing the OilReplacing Oil Servicing the Scavenge Line Orifice Cleaning the Inlet ScreenChanging the Oil Filter Element Changing the Second-Stage Separator ElementMotor winding resistance Troubleshooting GuideTroubleshooting Motor Winding ResistancePlatform troubleshooting guidelines Platform Symptoms DiagnosisSpecifications Compressor Module Specifications Dual-Compressor Module Technical Support and Service Max Flow/HP as a function of discharge Configuration Suction130 140 110180 Flow rate110 120 150Components and Hazard Statement Appendix A - Material Data Safety SheetSupplier Emergency Number 989 Product Name and InformationHealth Hazard Data Spill or Leak ProceduresFire and Explosion Hazards Reactivity DataPage Page Page Page EmersonClimate.com