Emerson SZV44, SZO44, SZV32, SZO56 manual Figures

Page 5

Dual-Compressor Module

TABLE OF CONTENTS

 

FIGURES

 

Figure 1

Compressor Module Components

3

Figure 2

Copeland Scroll® Compressor Cross Section

4

Figure 3

Typical Compressor Package

4

Figure 4

Compressor Module Dimensions, in. (mm)

7

Figure 5

Compressor Module Gas and Oil Flow Diagram and Safety Shutdowns

8

Figure 6

Brushless DC Fan

10

Figure 7

Basic Fan Control System

10

Figure 8

Optional Customer-Installed High Temperature Fan Control System

11

Figure 9

Oil Cooling and Thermal Valve

11

Figure 10

Motor Control

12

Figure 11

Typical Compressor Module Electrical Requirements

13

Figure 12

Control Circuit Terminations

14

Figure 13

Power Terminations

14

Figure 14

Maintenance Tools

18

Figure 15

Adding or Draining Oil

21

Figure 16

Gas Inlet Block and Screen

23

Figure 17

Scavenge Line Orifice

23

Figure 18

Oil Filter Bowl and Element

24

 

TABLES

 

Table 1

Inlet and discharge pressure limits

5

Table 2

Typical Compressor Module power supply requirements

13

Table 3

Maintenance summary

17

Table 4

Troubleshooting

25

Table 5

Motor winding resistance

25

Table 6

Platform troubleshooting guidelines

26

Table 7

Compressor Module specifications

27

Table 8

Compressor Module flow, pressure and horsepower data (see Notes 1 - 3*)

29

iii

2006SSD-75 R4 (10/10)

Image 5
Contents Copeland Scroll Compressor Module Page Table of Contents Appendix A Material Data Safety Sheet Figures Compressor Module Nomenclature Important Safety Information Safety Symbols Used in This Manual Safety Alert SymbolOil coolers with fans Compressor ModuleIntroduction Inlet gas scrubber for liquid removal CompressorCompressor Package General Installation Guidelines Installation GuidelinesInlet and Discharge Pressures Required Component-Inlet Gas ScrubberModule Weight Lbs. kg Ambient Temperature RangeBarg Setting Compressor Module Dimensions, in. mm Installation Clearance and DimensionsCode Description Process and Instrumentation Diagrams P&IDsSwitchStatus SwitchesElectrical Controls General ConsiderationsBrushless DC Fan Oil Cooler Fan ControlSZO44 Temperature ControlDrive Variable SpeedElectrical Requirements Typical Compressor Module power supply requirementsCompressor Power data based on 480VAC Variable Speed Control Circuit Terminations WiringPost-Startup Checklist Pre-Startup ChecklistInitial Startup Compressor Module OperationCheck for These Conditions Under Normal Operation Maintenance summary Routine MaintenanceMaintenance Maintenance Tools Maintenance ToolsOil Capacity and Type Checking the Oil LevelOil Level Guidelines Minimum Speed Oil Level Guidelines Maximum SpeedAdding Oil Adding and Removing OilTopping Off the Oil Level Draining Oil Changing the OilReplacing Oil Servicing the Scavenge Line Orifice Cleaning the Inlet ScreenChanging the Oil Filter Element Changing the Second-Stage Separator ElementTroubleshooting Troubleshooting GuideMotor Winding Resistance Motor winding resistancePlatform troubleshooting guidelines Platform Symptoms DiagnosisSpecifications Compressor Module Specifications Dual-Compressor Module Technical Support and Service Max Flow/HP as a function of discharge Configuration Suction130 140 110110 120 Flow rate150 180Supplier Appendix A - Material Data Safety SheetEmergency Number 989 Product Name and Information Components and Hazard StatementFire and Explosion Hazards Spill or Leak ProceduresReactivity Data Health Hazard DataPage Page Page Page EmersonClimate.com
Related manuals
Manual 42 pages 48.05 Kb