| Technical Support and Service |
Compressor Module
Horsepower Selection Chart
Module Model Number:
Configuration | Suction | Max Flow/HP as a function of discharge pressure at maximum |
|
|
|
| ||||||||||
| Press |
|
|
| flow rate | (Note 1) |
|
|
|
|
|
|
| |||
| (PSIG) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MCFD) | 70 | 80 | 90 | 100 |
| 110 | 120 | 130 | 140 | 150 | 160 | 170 | 180 | 190 | |
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
One Module Package | MCFD | 33 | 32 |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP | 14 | 15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0 | MCFD | 75 | 74 | 74 | 73 |
| 72 | 72 | 72 | 72 | 71 | 71 | 70 | 70 | 70 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP | 15 | 16 | 18 | 19 |
| 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 | MCFD | 101 | 100 | 100 | 99 |
| 99 | 98 | 98 | 97 | 97 | 97 | 96 | 96 | 95 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP | 16 | 17 | 19 | 20 |
| 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 10 | MCFD | 127 | 126 | 126 | 126 |
| 125 | 124 | 124 | 123 | 123 | 122 | 122 | 121 | 121 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP | 17 | 18 | 19 | 20 |
| 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 15 | MCFD |
| 152 | 152 | 152 |
| 152 | 151 | 150 | 150 | 149 | 148 | 148 | 147 | 147 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP |
| 19 | 20 | 21 |
| 23 | 23 | 24 | 25 | 27 | 28 | 29 | 30 | 31 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 20 | MCFD |
| 179 | 179 | 178 |
| 178 | 177 | 176 | 176 | 175 | 175 | 174 | 173 | 173 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP |
| 20 | 21 | 22 |
| 24 | 24 | 24 | 26 | 28 | 29 | 30 | 31 | 32 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 25 | MCFD |
|
|
| 204 |
| 203 | 203 | 203 | 202 | 202 | 201 | 200 | 199 | 199 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP |
|
|
| 23 |
| 24 | 24 | 25 | 27 | 28 | 30 | 31 | 32 | 33 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Two Module Package | MCFD | 66 | 64 |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP | 28 | 31 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0 | MCFD | 150 | 148 | 147 | 146 |
| 145 | 145 | 144 | 144 | 143 | 142 | 141 | 140 | 139 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP | 29 | 32 | 35 | 37 |
| 39 | 41 | 44 | 46 | 48 | 50 | 52 | 54 | 57 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 | MCFD | 201 | 201 | 200 | 199 |
| 197 | 197 | 196 | 195 | 194 | 193 | 192 | 191 | 191 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP | 32 | 34 | 37 | 39 |
| 41 | 43 | 46 | 48 | 50 | 52 | 54 | 56 | 58 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 10 | MCFD | 253 | 253 | 252 | 251 |
| 250 | 249 | 247 | 246 | 246 | 245 | 244 | 243 | 242 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP | 34 | 37 | 39 | 41 |
| 43 | 45 | 47 | 49 | 51 | 53 | 55 | 58 | 60 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 15 | MCFD |
| 305 | 305 | 304 |
| 303 | 301 | 300 | 299 | 298 | 297 | 296 | 295 | 294 |
|
| HP |
| 39 | 41 | 43 |
| 45 | 46 | 48 | 51 | 53 | 55 | 57 | 60 | 62 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 20 | MCFD |
| 357 | 357 | 356 |
| 356 | 354 | 353 | 352 | 351 | 349 | 348 | 347 | 345 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP |
| 41 | 43 | 45 |
| 47 | 47 | 49 | 52 | 55 | 57 | 59 | 61 | 64 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 25 | MCFD |
|
|
| 407 |
| 407 | 406 | 405 | 404 | 403 | 402 | 400 | 399 | 397 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP |
|
|
| 47 |
| 48 | 49 | 49 | 53 | 57 | 59 | 61 | 63 | 65 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTES:
1.Max flow using varibable speed drive, compressors operating at 80 Hz. max speed.
2.Standard test conditions: 60° F suction gas, 60° F ambient, 0.6 SG gas, 14.7 psia = 0 psig
3.Performance data to be used as an estimation guide only and is subject to change without notice
31 |