| Technical Support and Service |
|
|
Compressor Module
Horsepower Selection Chart
Module Model Number: SZO56C1A-EDE-240
Configuration | Suction | Max Flow/HP as a function of discharge pressure at maximum flow | ||||||||||
| Press |
|
|
| rate | (Note 1) |
|
|
|
| ||
| (PSIG) |
|
|
|
|
|
|
|
|
|
|
|
| MCFD) | 70 | 80 | 90 |
| 100 | 110 | 120 | 130 | 140 | 150 | |
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
One Module Package | MCFD | 43 | 42 |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP | 19 | 20 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0 | MCFD | 97 | 96 | 96 |
| 95 | 94 | 94 | 94 | 93 | 93 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP | 19 | 21 | 23 |
| 25 | 26 | 27 | 29 | 30 | 32 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 | MCFD | 131 | 130 | 130 |
| 129 | 128 | 128 | 127 | 127 | 126 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP | 21 | 23 | 24 |
| 26 | 27 | 29 | 30 | 31 | 33 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 10 | MCFD | 165 | 164 | 164 |
| 163 | 163 | 162 | 161 | 160 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP | 23 | 24 | 26 |
| 27 | 28 | 30 | 31 | 33 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 15 | MCFD |
| 198 | 198 |
| 197 | 197 | 196 | 195 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP |
| 25 | 27 |
| 28 | 30 | 31 | 32 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 20 | MCFD |
| 232 | 232 |
| 232 | 231 | 230 | 229 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP |
| 27 | 28 |
| 30 | 31 | 31 | 32 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 25 | MCFD |
|
|
|
| 265 | 264 | 264 | 264 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP |
|
|
|
| 31 | 31 | 32 | 33 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Two Module Package | MCFD | 86 | 84 |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP | 37 | 40 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0 | MCFD | 194 | 193 | 191 |
| 190 | 188 | 188 | 188 | 187 | 185 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP | 39 | 43 | 46 |
| 49 | 52 | 55 | 58 | 60 | 63 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 | MCFD | 262 | 261 | 259 |
| 258 | 257 | 256 | 255 | 253 | 252 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP | 42 | 45 | 49 |
| 52 | 54 | 57 | 60 | 63 | 66 |
| 10 | MCFD | 329 | 329 | 328 |
| 327 | 325 | 323 | 321 | 320 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP | 45 | 48 | 51 |
| 54 | 57 | 60 | 63 | 65 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 15 | MCFD |
| 396 | 396 |
| 395 | 394 | 392 | 390 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP |
| 51 | 54 |
| 57 | 59 | 61 | 63 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 20 | MCFD |
| 464 | 465 |
| 463 | 463 | 460 | 458 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP |
| 54 | 56 |
| 59 | 62 | 63 | 64 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 25 | MCFD |
|
|
|
| 530 | 529 | 528 | 527 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HP |
|
|
|
| 62 | 63 | 64 | 65 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTES:
1.Max flow using varibable speed drive, compressors operating at 80 Hz. max speed.
2.Standard test conditions: 60° F suction gas, 60° F ambient, 0.6 SG gas, 14.7 psia = 0 psig
3.Performance data to be used as an estimation guide only and is subject to change without notice
30 |