Emerson 396RVP instruction manual Ordering Information, Model

Page 7

MODEL 396R pH/ORP

SECTION 1.0

 

DESCRIPTION AND SPECIFICATIONS

1.3 ORDERING INFORMATION

The Model 396R Sensor is housed in a titanium tube, with a polypropylene reference junction and titanium solu- tion ground for use with a ball valve (order separately) for hot tap applications. The sensor is available with either a hemi or flat glass pH electrode and features a shrouded glass/platinum electrode and PT100 or 3K temperature compensation. The 396R is available with 9.5 in. or 15 ft of integral cable. The 396R sensor is not available with a preamp. Junction box kits with preamps must be ordered separately if the analyzer/transmitter does not have an integral preamp within 15 ft. of the probe. Process connector and ball valve assemblies must also be ordered separately.

MODEL

396R TUpH RETRACTABLE pH SENSOR

CODE

MEASURING ELECTRODE TYPE (Required Selection)

10

GPLR hemi glass, General Purpose Low Resistivity

 

 

12

ORP

 

 

13

GPLR flat glass, General Purpose Low Resistivity

 

 

 

 

CODE

SENSOR LENGTH

21

21 in. Titanium Tube

 

 

25

36 in. Titanium Tube

 

 

 

 

CODE

ANALYZER/TC COMPATIBILITY (Required Selection)

50

For Models 1181 (3K TC)

 

 

54

For Models 1054B, 1055, 2081,54e, 81, 3081, 4081, 5081, Xmt, SCL-(P/Q), (PT 100 RTD)

 

 

 

 

CODE

OPTIONAL OPTIONS

609.5 in. Cable with BNC (for use with Model 1181, 1054 series, 2054, 2081 Sensor Head J-Boxes)

619.5 in. Cable no BNC (Not Valid w/Option 50) (for use with Model 54e, 1055, 81, 3081, 4081, 5081, Xmt Sensor Head J-Boxes)

396R - 10 - 21 - 54

EXAMPLE

 

 

The Model 396RVP ball valve retractable sensor features a gel-filled electrolyte solution with the large area, coating resistant TUpH polypropylene reference junction and a standard hemi or optional flat glass bulb. Model 396RVP is housed in a Titanium sensor tube and can be mounted directly into the process using a 1 in. MNPT threaded process connector and a ball valve assembly kit (both ordered separately). It is offered with the water- tight Variopol sensor-to-cable connector and uses the mating connector cable (ordered separately). Also avail- able is a choice of temperature element, 3 K Balco or Pt 100 RTD. A remote preamplifier found in the analyzer/transmitter or in a junction box (ordered separately) must be used with this sensor for a reliable signal transmission.

MODEL

396RVP TUpH RETRACTABLE pH/ORP SENSOR

CODE

MEASURING ELECTRODE TYPE (Required Selection)

 

10

Hemi bulb, General Purpose Low Resistivity

 

 

 

 

12

ORP

 

 

 

 

13

Flat, GPLR glass

 

 

 

 

CODE

SENSOR LENGTH (Required Selection)

 

21

21 in. Titanium Tube

 

 

 

 

25

36 in. Titanium Tube

 

 

 

 

 

 

 

CODE

ANALYZER/TC COMPATIBILITY (Required Selection)

 

50

For Models 1181 (3K TC)

 

 

 

54

For Models 1054B, 1055, 2081,54e, 81, 3081, 4081, 5081, Xmt, SCL-(P/Q), (Pt 100 RTD)

 

 

 

396RVP-

10 - 21 - 54

EXAMPLE

 

 

 

3

Image 7
Contents Retractable pH/ORP Sensors Special Conditions for safe use Essential InstructionsModel 396R and 396RVP Table of ContentsList of Tables Figure No Title List of FiguresFeatures and Applications Section Description and SpecificationsMeasured Range Performance and Physical Specifications Model 396RMinimum Conductivity 100 µS/cm Weight/Shipping Weight Model 396RVPModel Ordering InformationBNC Adapter Choose one Commonly Used Accessories for Model 396ROther Accessories for Model 396R Choose oneOther Accessories for Model 396RVP Commonly Used Accessories for Model 396RVPInstallation Through Ball Valve Section InstallationSection Typical Mounting Configurations for Model 396R Dimensional Drawing Model 396R with Optional Ball Valve PN 40396R05 D 920 Front Side 396R-21 Back Side 396R Front Side 396R-25 Section Section Wiring Model 396R Section Wiring Model 396R40396R07 40396R012 40396R09 40396R13 40396R06 40396R21 40396R22 14. Wiring Model 396R- -54 to Model Wiring Model 396RVP Section Wiring Model 396RVPModel 81 Wiring Model 2081 Wiring 10. Model 1054 Wiring 14. Model 54/54e Wiring 18. Model Xmt-P-XX-10 Wiring 21. Model 1055-10-22-32 Wiring Recommended pH Sensor Standardization Recommended two point buffer calibration procedureSection Start UP and Calibration 396R pH CalibrationORP of Saturated Quinhydrone Solution Model 396R-25 36 tube Section MaintenanceRetractable Version Model 396R-21 21 tubeElements Compensation ElementsSection Example of Sensor Tube Replacement Description of Problem Remedy Section Diagnostics and TroubleshootingTroubleshooting with Diagnostics Diagnostic MessageSensors. For code 01, replace sensor General Warranty RepairNON-WARRANTY Repair Section Return of MaterialReturn of Material WarrantySpecifications subject to change without notice