Emerson Commonly Used Accessories for Model 396RVP, Other Accessories for Model 396RVP

Page 9

MODEL 396R pH/ORP

SECTION 1.0

 

DESCRIPTION AND SPECIFICATIONS

TABLE 1-3. COMMONLY USED ACCESSORIES FOR MODEL 396RVP

FOR FIRST TIME 396RVP AND 398RVP INSTALLATIONS, ROSEMOUNT ANALYTICAL RECOMMENDS USING THE FOLLOWING GUIDE:

1. Variopol Cable (required for all first time installations)

Choose one: PN 23645-06, 15 ft cable with mating VP connector, prepped with BNC on analyzer end PN 23645-07, 15 ft cable with mating VP connector, prepped without BNC on analyzer end*

2. Retractable Mounting

1A. Choose one (required for all first time installations, except as noted): PN 23166-00 1 in. x 1 in. NPT process connector, 316 SST PN 23166-01 1 in. x 1 in. NPT process connector, Titanium

Choose one (optional process connector o-rings): 1

PN 9550220, Kalrez® o-ring, 2-214 1

PN 9550099, Viton® o-ring, 2-214

1B. Choose one:

PN 23240-00 1-1/2 in. ball valve assembly, 316 SST

PN 23765-00 1-1/4 in. ball valve assembly, 316 SST (process connector not needed)

3. Remote Junction Boxes (Optional)

Choose one: PN 23555-00 includes preamplifier for Models 54e, 81, 3081, 4081, 1055, 5081, Xmt

PN 23309-03 and PN 22698-02 plug-in preamplifier for Model 1181Analyzer

PN 23309-04 and PN 22698-03 plug-in preamplifier for Models 1054 series and 2081 Analyzers

4. Extension cables

Choose one: PN 23646-01, 11 conductor, shielded, prepped

PN 9200273, 11 conductor, shielded, unprepped

*Used for connections to Models 1181, 2081, 54e, 81, 3081, 4081, 5081, Xmt, 1055, and remote junction box PN 23555-00.

2 kalrez and Viton are registered trademarks of DuPont Performance Elastomers.

TABLE 1-4. OTHER ACCESSORIES FOR MODEL 396RVP

PART

DESCRIPTION

22698-00

Preamplifier plug-in for junction box, for Model 1003,

22698-02

Preamplifier plug-in for junction box, for Models 1181, 1050

22698-03

Preamplifier plug-in for junction box, for Models 1054B, 2081

22743-01

Pt100 preamplifier for Model 1181

22744-01

3K Preamplifier for Model 1181

23557-00

Preamplifier for junction box for Models 54e, 81, 3081, 4081, 5081, Xmt, 1055

33046-00

Ferrule, 1 in., split 316SS

9310096

Nut, swage, 1 in. 316SST

9210012

Buffer solution, 4.01 pH, 16 oz

9210013

Buffer solution, 6.86 pH, 16 oz

9210014

Buffer solution, 9.18 pH, 16oz

R508-80Z

ORP solution, 460 mv ± 10 at 20°C

9550167

EPDM O-ring for Process Connector (PN 23166-00 or 23166-01)

12707-00

Jet Spray Cleaner

 

 

5

Image 9
Contents Retractable pH/ORP Sensors Special Conditions for safe use Essential InstructionsTable of Contents Model 396R and 396RVPList of Tables Figure No Title List of FiguresFeatures and Applications Section Description and SpecificationsMinimum Conductivity 100 µS/cm Weight/Shipping Weight Performance and Physical Specifications Model 396RModel 396RVP Measured RangeModel Ordering InformationOther Accessories for Model 396R Commonly Used Accessories for Model 396RChoose one BNC Adapter Choose oneOther Accessories for Model 396RVP Commonly Used Accessories for Model 396RVPInstallation Through Ball Valve Section InstallationSection Typical Mounting Configurations for Model 396R Dimensional Drawing Model 396R with Optional Ball Valve PN 40396R05 D 920 Front Side 396R-21 Back Side 396R Front Side 396R-25 Section Section Wiring Model 396R Section Wiring Model 396R40396R07 40396R012 40396R09 40396R13 40396R06 40396R21 40396R22 14. Wiring Model 396R- -54 to Model Wiring Model 396RVP Section Wiring Model 396RVPModel 81 Wiring Model 2081 Wiring 10. Model 1054 Wiring 14. Model 54/54e Wiring 18. Model Xmt-P-XX-10 Wiring 21. Model 1055-10-22-32 Wiring Section Start UP and Calibration Recommended two point buffer calibration procedure396R pH Calibration Recommended pH Sensor StandardizationORP of Saturated Quinhydrone Solution Retractable Version Section MaintenanceModel 396R-21 21 tube Model 396R-25 36 tubeElements Compensation ElementsSection Example of Sensor Tube Replacement Troubleshooting with Diagnostics Section Diagnostics and TroubleshootingDiagnostic Message Description of Problem RemedySensors. For code 01, replace sensor NON-WARRANTY Repair Warranty RepairSection Return of Material GeneralReturn of Material WarrantySpecifications subject to change without notice