Bosch Power Tools GPL5 manual 78 ft, 180˚

Page 8

Checking the Horizontal Leveling Accuracy of the Lateral Axis

A free measuring distance of 78 ft on a firm surface in front of a wall is required for the check.

Mount the measuring tool onto the multi- purpose attachment or a tripod, or place it on a firm and level surface at a distance of 78 ft to the wall. Switch the tool on.

Thus, the difference d between points I and II may not exceed 9/16 in (max.).

Checking the Horizontal Leveling Accuracy of the Longitudinal Axis

A free measuring distance of approximately 78 ft on a firm surface between two walls A and B is required for the check.

Mount the tool onto the multi-purpose attachment or a tripod, or place it on a firm and level surface close to wall A. Switch the tool on.

A

78

ft

 

B

Direct one of the two lateral laser beams, that run alongside the lateral axis of the tool, at the wall. Allow the tool to level in. Mark the center of the laser beam on the wall (point I).

78 ft

Direct the horizontal laser beam against the close wall A and allow the measuring tool to level in. Mark the center of the laser beam on the wall (point I).

d

A

180˚

180˚

B

Rotate the measuring tool by approx. 180° without changing its height. Allow it to level in and mark the center point of the other lateral laser beam on the wall (point II). Take care that point II is as vertical as possible above or below point I.

The difference d of both marked points I and II on the wall results in the actual height deviation of the tool alongside the lateral axis.

On the measuring distance of 2 x 78 ft = 156 ft, the maximum allowable deviation is:

156 ft x ±0.0036 in/ft = ±9/16 in (.563).

Turn the tool around by 180°, allow it to level in and mark the center point of the laser beam on the opposite wall

B (point II).

Without turning the tool, position it close to wall B. Switch the tool on and allow it to level in.

-8-

Image 8
Contents GPL5 Ver la páginaPage GPL General Safety Rules Always be Aware of their location when using the toolElectrical safety SaferFeatures Technical DataInserting/Replacing the Battery Intended UseSetting the Automatic Switch-off OperationLeveling Accuracy Influences on Accuracy78 ft 180˚Recalibration Procedure Checking the Vertical Leveling AccuracyPage Applications Plumbing a surfaceTransferring points with the plumb beam LevelingLevel Grading GradeWorking with the Tripod Optional Accessory Working with the Measuring Plate Optional AccessoryLaser Viewing Glasses Optional Accessory Use with AttachmentsKeep the tool clean at all times Environment ProtectionConsignes générales de sécurité AvertissementService aprŹs-vente Sécurité sur le lieu de travailSécurité électrique Sécurité personnelleEmploi prévu PréparationDonnées techniques Mise en place/changement des pilesConsignes d’utilisation Précision de nivellement20 m Procédure de réétalonnage Tracé auparavantDessinez une ligne droite sur le plafond Létape suivante Mise de niveau Mise d’aplomb d’une surfaceTransfert de points ą l’aide du faisceau de mise d’aplomb Nivellement NivellementMise ą léquerre Mise à léquerreMaintenance et service Travailler avec le trépied accessoireUtiliser avec la fixation Nettoyage et entretienPage Nomas generales de seguridad Guarde Estas InstruccionesUso previsto Preparación CaracterísticasDatos Técnicos Inserción y cambio de la pilaOperación Precisión de nivelaciónEn el eje transversal Láser puntoComprobación de la precisión de nivelación vertical Procedimientos de recalibraciónPage Aplicaciones Verticalización de una superficieEncienda el dispositivo GPL3 La distanciaPerpendicularidad GraduaciónGraduación Utilice con Base Mantenimiento y servicioEl tornillo Operación con trípode accesorio especial