Husky D29616 How to Stop, Before Starting, Cooling System not shown This compressor, Tool Storage

Page 12
Drain
Valve

Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use.

Cooling System (not shown): This compressor

contains an advanced design cooling system. At the heart of this cooling system is an engineered

fan. It is perfectly normal for this fan to blow air

through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.

Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.

Check Valve (not shown): When the air compressor is operating, the check valve is “open”, allowing compressed air to enter the air tank. When the air compressor reaches “cut-out” pressure, the check valve “closes”, allowing air pressure to remain inside the air tank.

Tool Storage: Grips and holds quick connect plug on tools and accessories in place for storage.

Tool Storage

Accessory Storage: Stores and protects accessories when not in use.

Accessory

Storage

How to Use Your Unit

How to Stop:

1.Set the On/Auto/Off switch to “OFF”.

Before Starting

Break-in Procedure

Serious damage may result if the following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the On/Auto/Off switch is in the "OFF" position.

NOTE: Pull coupler back until it clicks to prevent air from escaping through the quick connect.

D29616

12- ENG

Image 12
Contents Air Compressor Operator’s Manual Safety Guidelines Definitions Important Safety InstructionsOr serious injury Minor or moderate injury Death or serious injurySpray area. An additional length of hose Explosion May be requiredLocation away from compressor Fire, do not allow the compressor toAttachments & Accessories What Could HappenSafety equipment must be properly Electricity. Like any other electricallyRepairs attempted by unqualified Air to all applicable local and federalOr attempt maintenance until unit has Result in serious burnsHot for several minutes after operation Do not reach around protective shroudsFire, Inhalation, Damage to Vehicle Surfaces Specifications GlossaryDuty Cycle Model No Y6020Installation Location of the Air CompressorPlug OutletsExtension Cords Voltage and Circuit ProtectionOperation Know Your Air CompressorDescription of Operation How to Stop Accessory StorageBefore Starting Cooling System not shown This compressorHow to Start Before Each Start-UpMaintenance To Check Safety ValveCustomer Responsibilities To Drain TankService and Adjustments StorageTroubleshooting Pressure reading Problem Cause Correction Limited Warranty Husky Air Compressor warranted by DapcDefiniciones DE Normas DE Seguridad Muerte o lesiones seriasModeradas Lesiones serias Causar daños en la propiedadInstrucciones Importantes DE Seguridad Cómo prevenirloAdvertencia Riesgo de Explosión Qué puede occurrir Cómo prevenirloNunca opere el compresor sin sus defensas o Advertencia Riesgo de Quemaduras Qué puede occurrir Advertencia Riesgo de Caída Qué puede occurrirAdvertencia Riesgo de Operación Lasegura Qué puede occurrir Glosario Ciclo DE ServicioModelo No Y6020 Instalación Ubicación del compresor de airePlug Grounding Pin Grounded Outlets Cables de extensión eléctrica Protección del voltaje y del circuitoCondiciones Operación Conozca su compresor de aireDescripción de operaciones Cómo utilizar su unidad Cómo detenerlaAntes de poner en marcha Antes de cada puesta en marcha Cómo poner en marchaMantenimiento Responsabilidades del clienteCómo verificar la válvula de seguridad Cómo drenar el tanqueServicio Y Ajustes AlmacenajeAire, originando un riesgo de ruptura de sus paredes Guía DE Diagnóstico DE Problemas Sobre la soldadura o cosaAire, ello lo debilitará. El Tanque podría romperse oDesciende cuando El motor no funciona Garantía Limitada El compresor de aire Husky está garantizado por DapcMesures DE Sécurité Définitions Consignes DE Sécurité ImportantesOu la mort Causer des blessures mineures ou Moyennes Évité, peut causer des dommages à laConserver ces directives Avertissement Risque dexplosion ou dincendie PréventionAvertissement Risque déclatement Risque PréventionAvertissement Risque de projection dobjets Avertissement Risque de choc électrique Avertissement Risque par inhalationAvertissement Risque de brûlures Avertissement Risque relié aux pièces mobilesAvertissement Risque de chute Risque Avertissement Risque dune utilisation dangereuseCycle DE Service LexiqueSpécifications No de modèle Y6020Emplacement du compresseur dair FichePrises de courant mises à la terre Rallonges Protection contre la surtension et protection du circuitUtilisation Familiarisez-vous avec votre compresseur dairDescription du fonctionnement Régulateur Manomètre Du réservoir De sortieUtilisation de lappareil Arrêt de lappareilAvant le démarrage Avant chaque mise en marche Mise en marcheEntretien Responsabilités du clientVérification de la soupape de sûreté Vidange du réservoirEntretien ET Réglages RangementDépannage SerrerPeut éclater ou exploser Considérée normale Fusible sauté ou coupe-circuit 55- FR D29616 Garantie Limitée Le compresseur dair Husky est garanti par Dapc