DVB4136 Direct Vent Gas Fireplace

Optional Accessories

Fan Kits

FK12 Fan Assembly

1.Open louvre assembly bottom.

2.Install FK12 fan in back of unit between hearth sup- ports. (Fig. 77)

3.Secure fan on velcro strips.

4.Power to the fan can be supplied by plugging the supply lead into a conveniently located wall socket or by using a hard-wired EB-1 connector box.

5.Be sure fan motor does not touch hearth supports.

Side View

Cold Air Box

Front of

Unit

Hearth Pan

Base Pan

 

FK12 Fan

FP1004

Fig. 77 FK12 Fan Kit placement.

FK24 Fan Assembly

Fan specifications: 120 volt, 60 Hz, .75 Amp.

This fan does not need regular maintenance, however periodic cleaning is required. Check the area under the

Method A

Route the 6’ (1.8m) lead fitted to the unit to a conve- niently located wall socket.

Method B

If the EB-1 receptacle box (Pt. #ZA1200) was cor- rectly connected when the unit was installed, the fan lead can be directly plugged into the EB-1 plug socket.

5.Whether wiring directly to the fan junction box (Op- tion A) or into the EB1 (electrical box, Option B) first ensure cable is secured using box connector.

The fireplace, when installed must be elec- trically connected and grounded in accor- dance with local codes, with the current CSA C22.1 Canadian Electrical Code or for US installations, follow local codes and the National Electrical Code, ANSI/NFPA No. 70.

Hard (Direct) Wire Hook Up

First connect ground wire to ground stud located on the base of either box. Black wire from supply should connect to the variable speed switch. Alternate speed switch wire connects to temperature sensor. Alternate lead from sensor connects to fan. Alternate fan lead connects back to the white supply wire. (Fig. 79)

Any electrical rewiring of this fan must be completed by a qualified electrician.

Turn off all power before hook up.

control door and in front of the fan and wipe or vacuum at least once a month during the operating season. Should this fan require servicing, the power supply must be disconnected.

The FK24 comes with the electrical cord attached.

1. Slide fan assembly from the left side into the fire-

place opening, line up mounting holes with screw

Heat SensorFan

 

��

����

�� �

���

 

��

 

Electrical Box

 

studs on back of fireplace and fasten with #10 - 24

 

hex nuts. (Fig. 78)

2.

Install thermal sensor on bottom of firebox using #10

 

- 24 hex nuts.

3.

(Option A) - Place electronic fan speed control box

 

on bottom of fireplace base, lining up mounting holes

 

with screw studs. Fasten fan speed control box with

 

#10 - 24 hex nuts.

 

(Option B) - The speed control can be installed in an

 

electrical box at normal wall switch height for conve-

 

nient access.

4.

The power supply may be connected in 2 ways:

48

Fan Speed

Gas Line

Valve

FP1811

Switch

 

 

 

Fig. 78 FK24 fan placement.

Fan

Temperature

Sensor

Speed

Control

Black

White

Ground

FP1025

Fig. 79 FK24 fan wiring.

20012322

Page 48
Image 48
Majestic Appliances DVB4136 Optional Accessories, Fan Kits, FK12 Fan Assembly, FK24 Fan Assembly, Hard Direct Wire Hook Up