DVB4136 Direct Vent Gas Fireplace

LED Count

Service Action

8Replace valve

7Confirm stepper motor connection exists

5Confirm fan connection exists and works

4Confirm gas type; jumper in place

3Replace thermopiles

2Turn fan ON NOTE: Some keys are not active.

Auto Path

If the manual switch is

 

 

 

set to REMOTE, press

 

 

 

 

 

Move switch

the mode button to

 

 

 

 

from LOCAL to

display AUTO on the

 

 

 

 

REMOTE. Press

transmitter. Does the

 

 

 

 

any key within 30

transmitter display the

 

 

 

 

seconds.

room and temperature

 

 

 

 

 

setting?

 

 

 

Yes

If the setting is above room temperature on the transmitter, does the main valve and fan turn on?

No

Yes

If the setting is below room temperature on the transmitter, does the main valve and fan turn off?

Turn pilotstat knob to OFF to turn valve completely off

No

20012322

39

Page 39
Image 39
Majestic Appliances DVB4136 manual Auto Path, LED Count Service Action