Troubleshooting AF4000 Valve (continued)

Flame height adjustment will

Ensure the black and red leads from the battery pack or the AF4000 110H/L mod-

not work/works backwards

ule are securely connected to the red and black leads from the motor drive or H/L

 

latching solenoid located on the valve body (red to red and black to black).

 

Verify the selector switch on the battery pack is set to DC MOTOR DRIVE or

 

LATCHING SOLENOID, depending upon which device is installed.

 

Check functionality with all transmitters to determine if there is an issue with the

 

main control system or an individual transmitter. If the issue is with an individual

 

transmitter, make sure the batteries in both the transmitter and receiver are

 

installed in the proper direction and are not drained. Individual battery voltage

 

should be no less than 1.4V for AA and AAA batteries, 2.8V for button cells, and

 

9.0V for 12V batteries.

Figure 60: AF4000 MOD Module End

 

 

8 Pin IPI

6 Volt DC Adapter

 

 

Connection

 

 

 

 

 

 

 

Power Connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FP1764

Figure 61: AF4000 Valve Face

Main Connection

MAIN

Inlet

Pilot Adj. Figure 61: AF4000 Valve FaceManual background

PILOT

Outlet

FP1769

Pilot Connection