Majestic Appliances DVB4136 Final Finishing, Gas Specifications, Gas Inlet and Manifold Pressures

Models: DVB4136

1 52
Download 52 pages 13.38 Kb
Page 8
Image 8
Final Finishing

DVB4136 Direct Vent Gas Fireplace

 

 

3/4” (19 mm) Scribe

 

 

Moulding for use with

 

 

CFM Cabinets

 

Black

 

J

I H

 

 

 

G

Surround

 

 

 

Face

Mantel

 

 

F

 

 

 

 

CFM164a

Leg

 

 

 

Side of

 

 

MLK

 

Combustion Chamber

N

 

Gas Specifications O Gas Inlet and Manifold Pressures

CFM170

 

 

Mantel

 

Mantel Leg from Side

Ref.

Leg Depth

Ref.

of Comb. Opening

F

10”

(254 mm)

K

11¹⁄

(292 mm)

G

8”

(203 mm)

L

9¹⁄

(241 mm)

H

6”

(152 mm)

M

7¹⁄

(191 mm)

I

4”

(101 mm)

N

5¹⁄

(140 mm)

J

2”

(51 mm)

O

3¹⁄

(89 mm)

Fig. 4b Combustible mantel leg minimum installation.

Flange

Drywall

Flange Location for

Position

Depth

Desired Drywall Depth

A

1/2” / 13 mm

 

B

5/8” / 16 mm

 

AB

FP1539

Fig. 5 Drywall flange location.

Final Finishing

Noncombustible materials such as brick or tile can be extended over the edges of the face of the fireplace.

Do not cover the window frame assembly, any vent, louvre assembly top or louvre assembly bottom. If a Trim Kit is to be installed, brick and tile will have to be installed flush with the side of this appliance.

Gas Specifications

 

 

 

Max.

 

Min.

 

 

 

 

 

Gas

 

Input

 

Input

Model

Fuel

Control

BTU/h

 

BTU/h

DVB4136RN

Natural Gas

Millivolt Hi/Lo

30,000

 

18,500

DVB4136RP

Propane

Millivolt Hi/Lo

30,000

 

17,000

DVB4136IN

Natural Gas

24 Volt Hi/Lo

30,000

 

21,800

DVB4136IP

Propane

24 Volt Hi/Lo

30,000

 

21,300

DVB4136RFN

Natural Gas

Comfort Control

30,000

 

21,000

DVB4136RFP

Propane

Comfort Control

30,000

 

23,500

Gas Inlet and Manifold Pressures

 

Natural

LP (Propane)

Minimum Inlet Pressure

5.5” w.c.

11.0” w.c.

Maximum Inlet Pressure

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

 

 

 

High Elevations

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level.

For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m).

Gas Line Installation

When purging gas line the front glass must be removed.

The gas pipeline can be brought in through the right side of the appliance. Knockouts are provided at conve- nient locations to allow for the gas pipe installation and testing of any gas connection.

The gas line connection can be made with properly tinned 3/8” copper tubing, 1/2” rigid pipe or an approved flex connector. Since some municipalities have addi- tional local codes, it is always best to consult your local authority and the CSA-B149.1installation codes.

For USA installations consult the current National Fuel Gas Code, ANSI Z223.1/NFPA 54.